Application of digital volume correlation to study the efficacy of prophylactic vertebral augmentation.

BACKGROUND Prophylactic augmentation is meant to reinforce the vertebral body, but in some cases it is suspected to actually weaken it. Past studies only investigated structural failure and the surface strain distribution. To elucidate the failure mechanism of the augmented vertebra, more information is needed about the internal strain distribution. This study aims to measure, for the first time, the full-field three-dimensional strain distribution inside augmented vertebrae in the elastic regime and to failure. METHODS Eight porcine vertebrae were prophylactically-augmented using two augmentation materials. They were scanned with a micro-computed tomography scanner (38.8μm voxel resolution) while undeformed, and loaded at 5%, 10%, and 15% compressions. Internal strains (axial, antero-posterior and lateral-lateral components) were computed using digital volume correlation. FINDINGS For both augmentation materials, the highest strains were measured in the regions adjacent to the injected cement mass, whereas the cement-interdigitated-bone was less strained. While this was already visible in the elastic regime (5%), it was a predictor of the localization of failure, which became visible at higher degrees of compression (10% and 15%), when failure propagated across the trabecular bone. Localization of high strains and failure was consistent between specimens, but different between the cement types. INTERPRETATION This study indicated the potential of digital volume correlation in measuring the internal strain (elastic regime) and failure in augmented vertebrae. While the cement-interdigitated region becomes stiffer (less strained), the adjacent non-augmented trabecular bone is affected by the stress concentration induced by the cement mass. This approach can help establish better criteria to improve vertebroplasty.

[1]  M Viceconti,et al.  About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study. , 2014, Journal of biomechanics.

[2]  Klaus-Peter Schmitz,et al.  Minimum cement volume required in vertebral body augmentation--A biomechanical study comparing the permanent SpineJack device and balloon kyphoplasty in traumatic fracture. , 2015, Clinical biomechanics.

[3]  S. Belkoff,et al.  An Ex Vivo Biomechanical Evaluation of a Hydroxyapatite Cement for Use With Vertebroplasty , 2001, Spine.

[4]  K T Ison,et al.  The strengthening effect of percutaneous vertebroplasty. , 2000, Clinical radiology.

[5]  Sean Molloy,et al.  Effect of cement volume and placement on mechanical-property restoration resulting from vertebroplasty. , 2005, AJNR. American journal of neuroradiology.

[6]  J. Ahn,et al.  Risk factors of new compression fractures in adjacent vertebrae after percutaneous vertebroplasty , 2004, Acta radiologica.

[7]  T. Diamond,et al.  Management of acute osteoporotic vertebral fractures: a nonrandomized trial comparing percutaneous vertebroplasty with conservative therapy. , 2003, The American journal of medicine.

[8]  S. Boonen,et al.  Interspecies differences in bone composition, density, and quality: potential implications for in vivo bone research. , 1998, Endocrinology.

[9]  P. Doumalin,et al.  Study of mechanical behavior of cancellous bone by Digital Volume Correlation and X-ray Micro-Computed Tomography , 2008 .

[10]  A. Levine,et al.  Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures. , 1999, Spine.

[11]  I. Lieberman,et al.  Biomechanical changes after the augmentation of experimental osteoporotic vertebral compression fractures in the cadaveric thoracic spine. , 2005, The spine journal : official journal of the North American Spine Society.

[12]  Christoph Fankhauser,et al.  Augmentation of mechanical properties in osteoporotic vertebral bones – a biomechanical investigation of vertebroplasty efficacy with different bone cements , 2001, European Spine Journal.

[13]  Elise F Morgan,et al.  Presence of intervertebral discs alters observed stiffness and failure mechanisms in the vertebra. , 2013, Journal of biomechanics.

[14]  S. Molloy,et al.  The management of spinal metastases from renal cell carcinoma. , 2009, Annals of the Royal College of Surgeons of England.

[15]  Valentina Danesi,et al.  Reproducible reference frame for in vitro testing of the human vertebrae. , 2014, Journal of biomechanics.

[16]  Y. Shomura,et al.  Radiological Follow-up of New Compression Fractures Following Percutaneous Vertebroplasty , 2006, CardioVascular and Interventional Radiology.

[17]  B. Bay,et al.  Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements. , 2006, Journal of biomechanical engineering.

[18]  Ruth K Wilcox,et al.  The biomechanical effectiveness of prophylactic vertebroplasty: a dynamic cadaveric study. , 2008, Journal of neurosurgery. Spine.

[19]  Ruth K Wilcox,et al.  A Biomechanical Investigation of Vertebroplasty in Osteoporotic Compression Fractures and in Prophylactic Vertebral Reinforcement , 2007, Spine.

[20]  N. Crawford,et al.  Comparative anatomy of the porcine and human thoracic spines with reference to thoracoscopic surgical techniques , 2005, Surgical Endoscopy And Other Interventional Techniques.

[21]  W. Reece The Physiology of the Domestic Animals , 1889, Buffalo Medical and Surgical Journal.

[22]  J. S. R. del Barrio,et al.  Injectable acrylic bone cements for vertebroplasty with improved properties. , 2004, Journal of biomedical materials research. Part B, Applied biomaterials.

[23]  S. Spriano,et al.  MULTIFUNCTIONAL TITANIUM: SURFACE MODIFICATION PROCESS AND BIOLOGICAL RESPONSE , 2015 .

[24]  H Yamamoto,et al.  Mechanical augmentation of the vertebral body by calcium phosphate cement injection , 2001, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[25]  Gianluca Tozzi,et al.  Three-dimensional local measurements of bone strain and displacement: comparison of three digital volume correlation approaches. , 2015, Journal of biomechanical engineering.

[26]  Marco Viceconti,et al.  Mechanical testing of bones: the positive synergy of finite–element models and in vitro experiments , 2010, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[27]  C. Whyne,et al.  Image Registration Demonstrates the Growth Plate has a Variable Affect on Vertebral Strain , 2010, Annals of Biomedical Engineering.

[28]  Nico Verdonschot,et al.  The Influence of Endplate-to-Endplate Cement Augmentation on Vertebral Strength and Stiffness in Vertebroplasty , 2007, Spine.

[29]  J. Adams,et al.  Identification of vertebral fractures: An update , 2005, Osteoporosis International.

[30]  E. Morgan,et al.  Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone. , 2007, Journal of biomechanics.

[31]  Stephen J Ferguson,et al.  The Effectiveness of Percutaneous Vertebroplasty Is Determined by the Patient-Specific Bone Condition and the Treatment Strategy , 2016, PloS one.

[32]  Gerd Huber,et al.  Does the cement stiffness affect fatigue fracture strength of vertebrae after cement augmentation in osteoporotic patients? , 2013, European Spine Journal.

[33]  Egon Perilli,et al.  Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review. , 2014, Journal of biomechanics.

[34]  I. Sinclair,et al.  The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression. , 2014, Journal of the mechanical behavior of biomedical materials.

[35]  M. Connock,et al.  A systematic review of evidence on malignant spinal metastases: natural history and technologies for identifying patients at high risk of vertebral fracture and spinal cord compression. , 2013, Health technology assessment.

[36]  P. Zysset,et al.  An experimentally validated finite element method for augmented vertebral bodies. , 2013, Clinical biomechanics.

[37]  I. Han,et al.  MAGNETIC RESONANCE IMAGING FINDINGS OF SUBSEQUENT FRACTURES AFTER VERTEBROPLASTY , 2009, Neurosurgery.

[38]  Gianluca Tozzi,et al.  The use of digital image correlation in the biomechanical area: a review , 2016 .

[39]  D. Robertshaw,et al.  Temperature regulation and the thermal environment. , 2004 .

[40]  Nico Verdonschot,et al.  Prophylactic vertebroplasty can decrease the fracture risk of adjacent vertebrae: an in vitro cadaveric study. , 2014, Medical engineering & physics.

[41]  F. Hild,et al.  Computation of full-field displacements in a scaffold implant using digital volume correlation and finite element analysis. , 2013, Medical engineering & physics.

[42]  E. Maire,et al.  In Situ Experiments with X ray Tomography: an Attractive Tool for Experimental Mechanics , 2010 .

[43]  D. Kallmes,et al.  New fractures after vertebroplasty: adjacent fractures occur significantly sooner. , 2006, AJNR. American journal of neuroradiology.

[44]  J. Craigon,et al.  Physiological temperature variants and culture media modify meiotic progression and developmental potential of pig oocytes in vitro. , 2007, Reproduction.

[45]  T. Choma,et al.  Management of the Elderly With Vertebral Compression Fractures. , 2015, Neurosurgery.

[46]  Gladius Lewis,et al.  Injectable bone cements for use in vertebroplasty and kyphoplasty: state-of-the-art review. , 2006, Journal of biomedical materials research. Part B, Applied biomaterials.

[47]  P. Zysset,et al.  The effect of standard and low-modulus cement augmentation on the stiffness, strength, and endplate pressure distribution in vertebroplasty , 2012, European Spine Journal.

[48]  C. Whyne,et al.  Quantification of the effect of osteolytic metastases on bone strain within whole vertebrae using image registration , 2012, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[49]  Alessandro Freddi,et al.  Experimental Stress Analysis for Materials and Structures. Stress Analysis Models for Developing Design Methodologies , 2015 .

[50]  F. Grados,et al.  Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty. , 2009, Rheumatology.

[51]  Gianluca Tozzi,et al.  Microdamage assessment of bone-cement interfaces under monotonic and cyclic compression. , 2014, Journal of biomechanics.

[52]  A. Martínez-García,et al.  Determination of the Mechanical Properties of Lumbar Porcine Vertebrae with 2D Digital Image Correlation , 2015, Journal of applied biomaterials & functional materials.

[53]  L. Nolte,et al.  Adjacent vertebral failure after vertebroplasty. A biomechanical investigation. , 2002, The Journal of bone and joint surgery. British volume.

[54]  B. Bai,et al.  The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures. , 1999, Spine.

[55]  Ruth K Wilcox,et al.  Preliminary biomechanical evaluation of prophylactic vertebral reinforcement adjacent to vertebroplasty under cyclic loading. , 2009, The spine journal : official journal of the North American Spine Society.

[56]  Luca Cristofolini,et al.  USE OF DIGITAL IMAGE CORRELATION TO INVESTIGATE THE BIOMECHANICS OF THE VERTEBRA , 2015 .

[57]  R. Müller,et al.  Time-lapsed microstructural imaging of bone failure behavior. , 2004, Journal of biomechanics.

[58]  Been-Der Yang,et al.  Prophylactic Vertebroplasty May Reduce the Risk of Adjacent Intact Vertebra From Fatigue Injury: An Ex Vivo Biomechanical Study , 2009, Spine.

[59]  Hans-Joachim Wilke,et al.  Biomechanical Evaluation of Vertebroplasty and Kyphoplasty With Polymethyl Methacrylate or Calcium Phosphate Cement Under Cyclic Loading , 2006, Spine.

[60]  L. Grassi,et al.  Extracting accurate strain measurements in bone mechanics: A critical review of current methods. , 2015, Journal of the mechanical behavior of biomedical materials.

[61]  Joshua A Hirsch,et al.  Occurrence of new vertebral body fracture after percutaneous vertebroplasty in patients with osteoporosis. , 2003, Radiology.

[62]  Gianluca Tozzi,et al.  Elastic Full‐Field Strain Analysis and Microdamage Progression in the Vertebral Body from Digital Volume Correlation , 2016 .

[63]  Heath B. Henninger,et al.  Validation of computational models in biomechanics , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[64]  Gamal Baroud,et al.  Height restoration and maintenance after treating unstable osteoporotic vertebral compression fractures by cement augmentation is dependent on the cement volume used. , 2013, Clinical biomechanics.

[65]  Marco Viceconti,et al.  A PRELIMINARY IN VITRO BIOMECHANICAL EVALUATION OF PROPHYLACTIC CEMENT AUGMENTATION OF THE THORACOLUMBAR VERTEBRAE , 2016 .

[66]  R. Wilcox,et al.  The Biomechanical Effect of Vertebroplasty on the Adjacent Vertebral Body: A Finite Element Study , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[67]  N. Langrana,et al.  Biomechanical Effects of Unipedicular Vertebroplasty on Intact Vertebrae , 2003, Spine.

[68]  Gunnar B. J. Andersson,et al.  Biomechanical Evaluation of an Injectable Calcium Phosphate Cement for Vertebroplasty , 2002, Spine.

[69]  Philipp Schneider,et al.  Deformable image registration and 3D strain mapping for the quantitative assessment of cortical bone microdamage. , 2012, Journal of the mechanical behavior of biomedical materials.

[70]  Marco Viceconti,et al.  EXPERIMENTAL METHODS FOR THE BIOMECHANICAL INVESTIGATION OF THE HUMAN SPINE: A REVIEW , 2014 .

[71]  Y. Okajima,et al.  Prophylactic vertebroplasty: cement injection into non-fractured vertebral bodies during percutaneous vertebroplasty. , 2009, Academic radiology.

[72]  Lisa A Ferrara,et al.  Distribution of anterior cortical shear strain after a thoracic wedge compression fracture. , 2004, The spine journal : official journal of the North American Spine Society.

[73]  Marco Viceconti,et al.  Strain distribution in the lumbar vertebrae under different loading configurations. , 2013, The spine journal : official journal of the North American Spine Society.

[74]  Gladius Lewis,et al.  Evaluation of a synthetic vertebral body augmentation model for rapid and reliable cyclic compression life testing of materials for balloon kyphoplasty. , 2008, Journal of biomedical materials research. Part B, Applied biomaterials.

[75]  Paul E Barbone,et al.  Digital Volume Correlation for Study of the Mechanics of Whole Bones. , 2012, Procedia IUTAM.

[76]  B. Bay,et al.  Digital volume correlation: Three-dimensional strain mapping using X-ray tomography , 1999 .

[77]  J. Tong,et al.  3D real-time micromechanical compressive behaviour of bone-cement interface: experimental and finite element studies. , 2012, Journal of biomechanics.

[78]  M. Scorsetti,et al.  Percutaneous vertebral augmentation in metastatic disease: state of the art. , 2011, The journal of supportive oncology.

[79]  K. Sun,et al.  Biomechanics of Prophylactic Vertebral Reinforcement , 2004, Spine.