A voltage-controlled current source with regulated electrode bias-voltage for safe neural stimulation

A current source for neural stimulation is presented which converts arbitrary voltage signals to current-controlled signals while regulating the offset-voltage across the stimulation electrodes in order to keep the electrodes in an electrochemical state that allows for injecting a maximum charge. The offset-voltage can either be set to 0V or to a bias-voltage, e.g. of a few 100mV, as it can be advantageous for fully exploiting the charge injection capacity of iridium oxide electrodes.

[1]  A. Pugh The art of electronics. 2nd edn: By Paul Horowitz and Winfield Hill. Pp. 1125. Cambridge University Presss. 1989. £29.95, US$49.50 , 1990 .

[2]  Hessel Wijkstra,et al.  Acute animal studies on the use of an anodal block to reduce urethral resistance in sacral root stimulation , 1994 .

[3]  P. E. K. Donaldson,et al.  When are actively balanced biphasic ‘Lilly’ stimulating pulses necessary in a neurological prosthesis? , 2006, Medical and Biological Engineering and Computing.

[4]  Kenneth Horch,et al.  A charge-balanced pulse generator for nerve stimulation applications , 2008, Journal of Neuroscience Methods.

[5]  M. Ortmanns,et al.  A 0.1mm/sup 2/, Digitally Programmable Nerve Stimulation Pad Cell with High-Voltage Capability for a Retinal Implant , 2006, 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers.

[7]  N. Bhadra,et al.  Direct current electrical conduction block of peripheral nerve , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[8]  P. R. Troyk,et al.  Injectable microstimulator for functional electrical stimulation , 1991, Medical and Biological Engineering and Computing.

[9]  W. Graham Richards,et al.  Art of electronics , 1983, Nature.

[10]  P. E. K. Donaldson,et al.  When are actively balanced biphasic (‘Lilly’) stimulating pulses necessary in a neurological prosthesis? I Historical background; Pt resting potential;Q studies , 2006, Medical and Biological Engineering and Computing.

[11]  Barrett C. Craner,et al.  Design and Development of Medical Electronic Instrumentation , 2005 .

[12]  Philip R. Troyk,et al.  Potential-biased, asymmetric waveforms for charge-injection with activated iridium oxide (AIROF) neural stimulation electrodes , 2006, IEEE Transactions on Biomedical Engineering.

[13]  W. Grill,et al.  Inversion of the current-distance relationship by transient depolarization , 1997, IEEE Transactions on Biomedical Engineering.

[14]  Morten Kristian Haugland A miniature implantable nerve stimulator , 1997 .

[15]  Erik Bruun,et al.  An implantable mixed analog/digital neural stimulator circuit , 1999, ISCAS'99. Proceedings of the 1999 IEEE International Symposium on Circuits and Systems VLSI (Cat. No.99CH36349).

[16]  K. Kilgore,et al.  Nerve conduction block utilising high-frequency alternating current , 2004, Medical and Biological Engineering and Computing.

[17]  S. Pourmehdi,et al.  An externally powered, multichannel, implantable stimulator-telemeter for control of paralyzed muscle , 1998, IEEE Transactions on Biomedical Engineering.