Shared k‐space echo planar imaging with keyhole

Time‐dependent phenomena are of great interest, and researchers have sought to shed light on these processes with MRI, particularly in vivo. In this work, a new hybrid technique based on EPI and using the concept of keyhole imaging is presented. By sharing peripheral k‐space data between images and acquiring the keyhole more frequently, it is shown that the spatial resolution of the reconstructed images can be maintained. The method affords a higher temporal resolution and is more robust against susceptibility and chemical‐shift artifacts than single‐shot EPI. The method, termed shared k‐space echo planar imaging with keyhole (shared EPIK), has been implemented on a standard clinical scanner. Technical details, simulation results, phantom images, in vivo images, and fMRI results are presented. These results indicate that the new method is robust and may be used for dynamic MRI applications. Magn Reson Med 45:109–117, 2001. © 2001 Wiley‐Liss, Inc.

[1]  X Hu,et al.  Continuous Update with Random Encoding (CURE): A New Strategy for Dynamic Imaging , 1995, Magnetic resonance in medicine.

[2]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[3]  Koichi Oshio,et al.  Phase errors in multi‐shot echo planar imaging , 1994, Magnetic resonance in medicine.

[4]  P. Mansfield Multi-planar image formation using NMR spin echoes , 1977 .

[5]  S J Riederer,et al.  Interleaved echo planar imaging on a standard MRI system , 1994, Magnetic resonance in medicine.

[6]  H. Pfeifer Principles of Nuclear Magnetic Resonance Microscopy , 1992 .

[7]  D A Feinberg,et al.  GRASE (gradient- and spin-echo) MR imaging: a new fast clinical imaging technique. , 1991, Radiology.

[8]  J. Frahm,et al.  Dynamic MR imaging of human brain oxygenation during rest and photic stimulation , 1992, Journal of magnetic resonance imaging : JMRI.

[9]  J Xiong,et al.  Improving the temporal resolution of functional MR imaging using keyhole techniques , 1996, Magnetic resonance in medicine.

[10]  Karl J. Friston,et al.  Statistical parametric maps in functional imaging: A general linear approach , 1994 .

[11]  A. Haase,et al.  Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging , 1990, Magnetic resonance in medicine.

[12]  M H Buonocore,et al.  High spatial resolution EPI using an odd number of interleaves , 1999, Magnetic resonance in medicine.

[13]  R. Turner,et al.  Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[14]  P Mansfield,et al.  Echo‐volumar imaging (EVI) at 0.5 T: First whole‐body volunteer studies , 1996, Magnetic resonance in medicine.

[15]  J C Gore,et al.  Functional brain imaging at 1.5 T using conventional gradient echo MR imaging techniques. , 1993, Magnetic resonance imaging.

[16]  J. J. van Vaals,et al.  “Keyhole” method for accelerating imaging of contrast agent uptake , 1993, Journal of magnetic resonance imaging : JMRI.

[17]  D. Tank,et al.  4 Tesla gradient recalled echo characteristics of photic stimulation‐induced signal changes in the human primary visual cortex , 1993 .

[18]  J N Lee,et al.  MR fluoroscopy: Technical feasibility , 1988, Magnetic resonance in medicine.

[19]  X Hu,et al.  On the “keyhole” technique , 1994, Journal of magnetic resonance imaging : JMRI.

[20]  G. Mckinnon Ultrafast interleaved gradient‐echo‐planar imaging on a standard scanner , 1993, Magnetic resonance in medicine.

[21]  D. Feinberg,et al.  GRASE (Gradient‐and Spin‐Echo) imaging: A novel fast MRI technique , 1991, Magnetic resonance in medicine.

[22]  J. Hennig,et al.  Improvement of spatial resolution of keyhole effect images , 1996, NeuroImage.

[23]  M. Buonocore,et al.  Ghost artifact reduction for echo planar imaging using image phase correction , 1997, Magnetic resonance in medicine.

[24]  O. Haraldseth,et al.  K‐space substitution: A novel dynamic imaging technique , 1993, Magnetic resonance in medicine.

[25]  T. Spraggins Simulation of spatial and contrast distortions in keyhole imaging , 1994, Magnetic resonance in medicine.

[26]  Karl J. Friston,et al.  Spatial registration and normalization of images , 1995 .

[27]  J Xiong,et al.  The effects of k-space data undersampling and discontinuities in keyhole functional MRI. , 1999, Magnetic resonance imaging.

[28]  F. Hennel Image-based reduction of artifacts in multishot echo-planar imaging. , 1998, Journal of magnetic resonance.

[29]  A G Webb,et al.  Applications of reduced‐encoding MR imaging with generalized‐series reconstruction (RIGR) , 1993, Journal of magnetic resonance imaging : JMRI.

[30]  H Bruder,et al.  Image reconstruction for echo planar imaging with nonequidistant k‐space sampling , 1992, Magnetic resonance in medicine.

[31]  S Chandra,et al.  Application of reduced‐encoding imaging with generalized‐series reconstruction (RIGR) in dynamic MR imaging , 1996, Journal of magnetic resonance imaging : JMRI.

[32]  A. Haase,et al.  Rapid NMR Imaging Using Low Flip-Angle Pulses , 2004 .

[33]  N. Logothetis,et al.  Functional imaging of the monkey brain , 1999, Nature Neuroscience.

[34]  Ravi S. Menon,et al.  Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging. , 1992, Proceedings of the National Academy of Sciences of the United States of America.