Synchronization method for grid integrated battery storage systems during asymmetrical grid faults

This paper aims at presenting a robust and reliable synchronization method for battery storage systems during asymmetrical grid faults. For this purpose, a Matlab/Simulink based model for testing of the power electronic interface between the grid and the battery storage systems has been developed. The synchronization method proposed in the paper is based on the proportionalintegral resonant controller with the delay signal cancellation. The validity of the synchronization method has been verified using the advanced laboratory station for the control of grid connected distributed energy sources. The proposed synchronization method has eliminated unfavourable components from the estimated grid angular frequency, leading to the more accurate and reliable tracking of the grid voltage vector positive sequence during both the normal operation and the operation during asymmetrical grid faults.

[1]  Vladimir A. Katic,et al.  Electric and hybrid vehicles battery charger cluster locations in urban areas , 2015, 2015 17th European Conference on Power Electronics and Applications (EPE'15 ECCE-Europe).

[2]  J. Svensson,et al.  Tuning software phase-locked loop for series-connected converters , 2005, IEEE Transactions on Power Delivery.

[3]  Xia Yong-feng Rapid and Intelligent Charging Technology for Series Lithium-ion Battery , 2008 .

[4]  Saad Mekhilef,et al.  DSP-based fuzzy logic controller for a battery charger , 2002, 2002 IEEE Region 10 Conference on Computers, Communications, Control and Power Engineering. TENCOM '02. Proceedings..

[5]  João Peças Lopes,et al.  Electric vehicle integration into modern power networks , 2013 .

[6]  Thanh Tu Vo,et al.  Charging algorithms of lithium-ion batteries: An overview , 2012, 2012 7th IEEE Conference on Industrial Electronics and Applications (ICIEA).

[7]  Se-Kyo Chung,et al.  A phase tracking system for three phase utility interface inverters , 2000 .

[8]  Zoltan Corba,et al.  Advanced laboratory setup for control of electrical drives as an educational and developmental tool , 2013, Eurocon 2013.

[9]  Francis P. Dawson,et al.  New synchronization method for thyristor power converters to weak AC-systems , 1993, IEEE Trans. Ind. Electron..

[10]  Yun Wei Li,et al.  Grid synchronization PLL based on cascaded delayed signal cancellation , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[11]  J. Svensson,et al.  Practical Implementation of Delayed Signal Cancellation Method for Phase-Sequence Separation , 2007, IEEE Transactions on Power Delivery.

[12]  Josep M. Guerrero,et al.  Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design Guidelines , 2014, IEEE Transactions on Power Electronics.

[13]  Nihal Kularatna,et al.  Rechargeable batteries and their management , 2011, IEEE Instrumentation & Measurement Magazine.

[14]  Kazunori Ozawa,et al.  Lithium Ion Rechargeable Batteries , 2009 .

[15]  Tsair-Rong Chen,et al.  Sinusoidal-Ripple-Current Charging Strategy and Optimal Charging Frequency Study for Li-Ion Batteries , 2013, IEEE Transactions on Industrial Electronics.

[16]  Zhe Chen,et al.  Multiple-Complex Coefficient-Filter-Based Phase-Locked Loop and Synchronization Technique for Three-Phase Grid-Interfaced Converters in Distributed Utility Networks , 2011, IEEE Transactions on Industrial Electronics.

[17]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[18]  Emile Yammine,et al.  Review on different charging techniques of lead-acid batteries , 2015, 2015 Third International Conference on Technological Advances in Electrical, Electronics and Computer Engineering (TAEECE).

[19]  J. Biela,et al.  Low-voltage fault ride through of the modular multilevel converter in a battery energy storage system connected directly to the medium voltage grid , 2014, 2014 16th European Conference on Power Electronics and Applications.

[20]  Marco Liserre,et al.  Grid Converters for Photovoltaic and Wind Power Systems , 2011 .

[21]  Frede Blaabjerg,et al.  Synchronization of grid-connected renewable energy sources under highly distorted voltages and unbalanced grid faults , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[22]  Michael J. Hoffmann,et al.  Studies on preventing Li dendrite formation in Li–S batteries by using pre-lithiated Si microwire anodes , 2014 .

[23]  Z. R. Ivanovic,et al.  HIL Evaluation of Power Flow Control Strategies for Energy Storage Connected to Smart Grid Under Unbalanced Conditions , 2012, IEEE Transactions on Power Electronics.