Development of portable device measuring the vital sign continuously with no limit of time and space is absolutely prerequisite for the U-health care that grafts the ubiquitous concept into medical system. Accordingly, it requires to develop a garment style apparatus for measuring vital-sign that is easy to wear on for a long time period. This study suggests a method to improve the insulation of electric cable and the skin adhesion of electrode by integrating the electric conductive material to garment, in order to develop a garment apparatus for measuring ECG for U-health care. Results of the research are as follows; In order to provide the adjacent conductive yarns with insulation, braid with narrow woven end was interlaced using polyester yarn. As a result, the direct contact between electric conductive yarns was restrained, which would be interposed into pin-tuck structured cable. Washable silicone gel applied around the electrode made of electric conductive fabric improved the adhesion, which prevents electrodes from dropping off from the skin surface during body movement. ECG signals on the human subject were tested using the garment apparatus developed by the above method. And the result was that the clear QRS wave formation in the typical form of ECG could be measured in both conditions of still and moving state as well. The result of this study is expected to contribute for the production of U-health care related medical apparatus by accelerating the practical uses of the garment measuring vital sign at a reasonable price.
[1]
Kevin Cleary,et al.
Feasibility of simultaneous respiratory function monitoring and determination of respiratory-related intrahepatic vessel excursion using the LifeShirt? system
,
2004,
CARS.
[2]
Neil Gershenfeld,et al.
E-broidery: Design and fabrication of textile-based computing
,
2000,
IBM Syst. J..
[3]
Enzo Pasquale Scilingo,et al.
Performance evaluation of sensing fabrics for monitoring physiological and biomechanical variables
,
2005,
IEEE Transactions on Information Technology in Biomedicine.
[4]
ณรงค์ โพธิ,et al.
การพัฒนาโปรแกรมตรวจสอบเว็บไซต์ที่ไม่เหมาะสมสำหรับเครื่องคอมพิวเตอร์ลูกข่าย เอ็กซ์พลอเรอร์ เบราเซอร์
,
2005
.
[5]
Eric J. Lind,et al.
A sensate liner for personnel monitoring applications
,
1998
.
[6]
Robert Puers,et al.
Towards the integration of textile sensors in a wireless monitoring suit
,
2004
.
[7]
A Goossens,et al.
Contact dermatitis from electrocardiograph‐monitoring electrodes: role of p‐tert‐butylphenol‐formaldehyde resin
,
2003,
Contact dermatitis.
[8]
João Paulo Costa,et al.
A Level-Based Approach to Prioritize Telecommunications R&D
,
2008
.