One-dimensional stitching interferometry assisted by a triple-beam interferometer.

In this work, we proposed for stitching interferometry to use a triple-beam interferometer to measure both the distance and the tilt for all sub-apertures before the stitching process. The relative piston between two neighboring sub-apertures is then calculated by using the data in the overlapping area. Comparisons are made between our method, and the classical least-squares principle stitching method. Our method can improve the accuracy and repeatability of the classical stitching method when a large number of sub-aperture topographies are taken into account. Our simulations and experiments on flat and spherical mirrors indicate that our proposed method can decrease the influence of the interferometer error from the stitched result. The comparison of stitching system with Fizeau interferometry data is about 2 nm root mean squares and the repeatability is within ± 2.5 nm peak to valley.

[1]  Self-calibrating lateral scanning white-light interferometer. , 2010, Applied optics.

[2]  G. Forbes,et al.  Stitching Interferometry: A Flexible Solution for Surface Metrology , 2003 .

[3]  Osuk Y. Kwon,et al.  Full Aperture Testing With Subaperture Test Optics , 1983, Optics & Photonics.

[4]  Cheng-Chung Lee,et al.  Vibration modulated subaperture stitching interferometry. , 2013, Optics express.

[5]  C Elster,et al.  Absolute profile measurement of large moderately flat optical surfaces with high dynamic range. , 2008, Optics express.

[6]  Michael Bray Stitching interferometry and absolute surface shape metrology: similarities , 2001, Optics + Photonics.

[7]  Kaiwei Wang,et al.  Influence of alignment error and random noise on interferometry flat sub-aperture stitching , 2012, Other Conferences.

[8]  Clemens Elster,et al.  Coupled distance sensor systems for high-accuracy topography measurement: Accounting for scanning stage and systematic sensor errors , 2006 .

[9]  T. Ishikawa,et al.  Microstitching interferometry for x-ray reflective optics , 2003 .

[10]  Clemens Elster,et al.  Traceable multiple sensor system for measuring curved surface profiles with high accuracy and high lateral resolution , 2006 .

[11]  Frank Siewert,et al.  Accuracy evaluation for sub-aperture interferometry measurements of a synchrotron mirror using virtual experiments , 2011 .

[12]  James H. Burge,et al.  Subaperture stitching performance estimation , 2013, Optics & Photonics - Optical Engineering + Applications.

[13]  Shanyong Chen,et al.  Error reductions for stitching test of large optical flats , 2012 .

[14]  Xin Jia,et al.  Analysis of absolute flatness testing in sub-stitching interferometer , 2016, International Symposium on Advanced Optical Manufacturing and Testing Technologies (AOMATT).

[15]  Xiangzhao Wang,et al.  A high-accuracy subaperture stitching system for nonflatness measurement of wafer stage mirror , 2014, Photonics Asia.

[16]  G N Lawrence,et al.  Method for subaperture testing interferogram reduction. , 1983, Optics letters.

[17]  T. Ishikawa,et al.  Relative angle determinable stitching interferometry for hard x-ray reflective optics , 2005 .