Multicomponent flow injection based analysis with diode array detection and partial least squares multivariate calibration evaluation. Rapid determination of Ca(II) and Mg(II) in waters and dialysis liquids

Flow injection analysis (FIA) with multiwavelength scanning of the FIA peaks using a diode array detector (DAD) has been combined with a multivariate calibration approach applying the partial least squares (PLS) method for the data evaluation. In this way, various side effects like dilution of the reagent, high blank, absorbance changes due to the pH gradient throughout the peak and/or the other interferences can be accounted for. Thus, even with a simple FIA manifold instrumentation the satisfactory results of multicomponent analysis are obtained. The method described has been checked on analysis of binary (Ca and Mg) and ternary (Ca, Mg and Cu) mixtures with pyridylazo resorcinol (PAR) as reagent and applied for rapid determination of calcium and magnesium in dialysis liquids and waters.

[1]  T. Yamane,et al.  Simultaneous determination of calcium and magnesium by using a flow-injection system with simultaneous injection of two sample plugs and a masking agent plug. , 1991, Talanta.

[2]  Jordi Coello,et al.  Multi-component analysis of concentrated solutions by flow-injection analysis with zone sampling and partial least-squares resolution , 1992 .

[3]  Paul J. Worsfold,et al.  Partial least squares resolution of multianalyte flow injection data , 1993 .

[4]  L. E. Wangen,et al.  A theoretical foundation for the PLS algorithm , 1987 .

[5]  Arthur I. Vogel,et al.  Vogel's Textbook of Quantitative Chemical Analysis , 1989 .

[6]  S. Maspoch,et al.  Diode-array detectors in flow-injection analysis Mixture resolution by multi-wavelength analysis. , 1987, Talanta.

[7]  Svante Wold,et al.  Partial least-squares method for spectrofluorimetric analysis of mixtures of humic acid and lignin sulfonate , 1983 .

[8]  J. Coello,et al.  Use of diode-array detectors for the simultaneous spectrophotometric determination of calcium and magnesium by flow injection , 1989 .

[9]  Bruce R. Kowalski,et al.  Evaluation of potentiometric acid-base titrations by partial-least-squares calibration , 1988 .

[10]  B. Kowalski,et al.  DOUBLE-INJECTION FLOW INJECTION ANALYSIS USING MULTIVARIATE CALIBRATION FOR MULTICOMPONENT ANALYSIS , 1991 .

[11]  F. Jiménez,et al.  Evaluation of multicomponent kinetic analysis data by a partial least squares calibration method , 1993 .

[12]  Wolfhard Wegscheider,et al.  Spectrophotometric multicomponent analysis applied to trace metal determinations , 1985 .

[13]  W. Lindberg,et al.  Multicomponent determinations in flow systems by partial least squares modeling , 1988 .

[14]  V. Cerdà,et al.  Simultaneous spectrophotometric determination of calcium and magnesium in water , 1991 .