IEA EBC Annex 59: High temperature cooling and low temperature heating in buildings

Abstract Improving the energy performance of the heating, ventilation and air-conditioning (HVAC) system is a key issue for building energy conversation. IEA (International Energy Agency) EBC (Energy in Buildings and Communities) Annex 59 presents a new perspective and a new concept to analyze the HVAC system in buildings. The project is organized following the idea of reducing mixing loss and transfer loss, and the work subtasks are arranged in response to the current insufficiency or inadequateness of HVAC system. Temperature level and temperature difference ΔT are emphasized in heating and cooling systems for buildings as well as heating/cooling capacity Q. Four subtasks are organized under the framework of Annex 59 dealing with different aspects of high temperature cooling (HTC) and low temperature heating (LTH) systems. Subtask A focuses on the principles and methodology. Entransy dissipation ΔEn and equivalent thermal resistance R are recommended as indexes to investigate the transfer characteristics of an air-conditioning system. The objective of subtask B is to propose suitable indoor terminals from the viewpoint of avoiding mixing loss in spaces. Subtask C focuses on outdoor air handling process, especially for treatment of moisture. Subtask D focuses on total system analysis including case studies, with an objective to design HTC and LTH system appropriately. The present analysis is beneficial to cast light on the Annex 59 project and propose novel approaches for performance optimization of air-conditioning systems.

[1]  Arif Hepbasli,et al.  Exergetic modeling and experimental performance assessment of a novel desiccant cooling system , 2011 .

[2]  XinGang Liang,et al.  Entransy—A physical quantity describing heat transfer ability , 2007 .

[3]  S. C. Kaushik,et al.  Second law thermodynamic study of heat exchangers: A review , 2014 .

[4]  Reinhard Radermacher,et al.  Application of entransy dissipation based thermal resistance to design optimization of a novel finless evaporator , 2016 .

[5]  Yi Jiang,et al.  Match properties of heat transfer and coupled heat and mass transfer processes in air-conditioning system , 2012 .

[6]  Luis Pérez-Lombard,et al.  A review on buildings energy consumption information , 2008 .

[7]  P. G. Luscuere,et al.  An exergy application for analysis of buildings and HVAC systems , 2010 .

[8]  Huijin Xu,et al.  Thermal performance of cascaded thermal storage with phase-change materials (PCMs). Part I: Steady cases , 2017 .

[9]  Arif Hepbasli,et al.  Thermodynamic analysis of a building using exergy analysis method , 2011 .

[10]  Melda Ozdinc Carpinlioglu,et al.  A comment on the concept of entransy (versus exergy) for the performance assessment of a desiccant cooling system , 2015 .

[11]  Yi Jiang,et al.  Performance comparison of liquid desiccant air handling processes from the perspective of match properties , 2013 .

[12]  Andrew G. Alleyne,et al.  Exergy-based optimal control of a vapor compression system , 2015 .

[13]  Yi Jiang,et al.  Application of entransy in the analysis of HVAC systems in buildings , 2013 .

[14]  Tao Zhang,et al.  Temperature and Humidity Independent Control (THIC) of Air-conditioning System , 2014 .

[15]  Dietrich Schmidt Low Exergy Systems for High-Performance Buildings and Communities , 2009 .

[16]  Tao Zhang,et al.  Development of temperature and humidity independent control (THIC) air-conditioning systems in China—A review , 2014 .

[17]  Yi Jiang,et al.  Entransy analysis and application of a novel indoor cooling system in a large space building , 2015 .