Comparison of three applications of ConTraSPECT

Today, the trend in SPECT attenuation correction is to acquire a transmission data set and reconstruct the corresponding attenuation map, for incorporating into the emission reconstruction. Recently, some techniques have been developed to determine the attenuation map directly from the emission data, by exploiting the fact that in the absence of noise only some specific transmission data can be consistent with given emission data. The consistency conditions relating the measured emission data to the sinogram of the attenuation distribution could theoretically allow recovery of the exact attenuation map. However it is necessary to include some a priori information so that the consistency conditions can be used stably. In this paper, three types of a priori information are used: a uniform ellipse, a uniform spline curve, and a uniform spline curve knowing the untruncated part of the transmission sinogram. Once the corresponding attenuation map has been computed, it is used to correct for attenuation in the emission image reconstruction process. The three methods have been tested on both simulations and experimentally acquired data. The results show that the two first methods give equivalent acceptable results, while the third method provides reconstructions which better fit baseline reconstructions obtained when the attenuation map is computed from acquired transmission data.

[1]  Chi-Hua Tung,et al.  The design and performance of a simultaneous transmission and emission tomography system , 1998 .

[2]  Grant T. Gullberg,et al.  Toward accurate attenuation correction in SPECT without transmission measurements , 1997, IEEE Transactions on Medical Imaging.

[3]  B.M.W. Tsui,et al.  Quantitative cardiac SPECT reconstruction with reduced image degradation due to patient anatomy , 1993, 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference.

[4]  Y. Censor,et al.  A New Approach to the Emission Computerized Tomography Problem: Simultaneous Calculation of Attenuation and Activity Coefficients , 1979, IEEE Transactions on Nuclear Science.

[5]  Frank Natterer,et al.  Determination of tissue attenuation in emission tomography of optically dense media , 1993 .

[6]  A. V. Bronnikov,et al.  Approximate reconstruction of attenuation map in SPECT imaging , 1995 .

[7]  F. Natterer The Mathematics of Computerized Tomography , 1986 .

[8]  M. Ljungberg,et al.  A Monte Carlo program for the simulation of scintillation camera characteristics. , 1989, Computer methods and programs in biomedicine.

[9]  Grant T. Gullberg,et al.  A comparison of Gd/Tc versus Tc/Tl simultaneous transmission and emission imaging using both single and triple detector fan-beam SPECT systems , 1994 .

[10]  S. H. Manglos,et al.  Constrained IntraSPECT reconstruction from SPECT projections , 1993, 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference.

[11]  J R Perry,et al.  Correction of nonuniform attenuation in cardiac SPECT imaging. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.