Comparative study of colloidal gold and quantum dots as labels for multiplex screening tests for multi-mycotoxin detection.

Quantum dots (QDs) and colloidal gold nanoparticles (CG) were evaluated as labels for multiplex lateral flow immunoassay (LFIA) for determination of mycotoxins deoxynivalenol (DON), zearalenone (ZEN) and T2/HT2-toxin (T2/HT2) in cereal matrices. Both developed assays were based on the same immunoreagents (except for the labels), therefore their analytical characteristics could be objectively compared. For both LFIAs antigens (DON-ovalbumin (OVA), ZEN-OVA and T2-OVA) and rabbit anti-mouse immunoglobulin were immobilized on a nitrocellulose membrane as three test lines and one control line, respectively. Depending on the LFIA, monoclonal antibodies (mAb) against DON, ZEN and T2 were conjugated with CdSeS/ZnS QDs or CG. T2 and HT2 were detected by one test line (T2-OVA) with an anti-T2 mAb which showed 110% cross-reactivity with HT2. Both tests were developed in accordance with the legal limits and were developed in such a way that they had the same cut-off limits of 1000 μg kg-1, 80 μg kg-1 and 80 μg kg-1 for DON, ZEN and T2/HT2, respectively in order to allow a correct comparison. Applicability of these assays was demonstrated by analysis of naturally contaminated wheat samples. The results demonstrate that both the LFIAs can be used as rapid, cost-effective and convenient qualitative tool for on-site screening for simultaneous detection of DON, ZEN and HT2/T2 in wheat without special instrumentation. However, the QD-based LFIA consumed less immunoreagents and was more sensitive and economically beneficial. In addition, the results were easier to interpret, resulting in a lower false negative rate (<5%) which was in good agreement with Commission Decision 2002/657/EC regarding the performance of analytical methods intended for screening purposes.

[1]  A. Santini,et al.  Fusaproliferin, beauvericin and enniatins: occurrence in food – a review , 2012 .

[2]  M. Busman,et al.  Rapid and advanced tools for mycotoxin analysis: a review , 2010, Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment.

[3]  F. Cardoso,et al.  Quantitative biomolecular sensing station based on magnetoresistive patterned arrays. , 2012, Biosensors & bioelectronics.

[4]  AOAC INTERNATIONAL Guidelines for Validation of Qualitative Binary Chemistry Methods. , 2014, Journal of AOAC International.

[5]  Dongjin Pyo Comparison of Fluorescence Immunochromatographic Assay Strip and Gold Colloidal Immunochromatographic Assay Strip for Detection of Microcystin , 2007 .

[6]  B. Fox,et al.  Mycotoxins , 1975, British Journal of Cancer.

[7]  Igor L. Medintz,et al.  Biosensing with Luminescent Semiconductor Quantum Dots , 2006, Sensors (Basel, Switzerland).

[8]  Alexandr E. Urusov,et al.  Immunochromatographic assay for the detection of ochratoxin A , 2011 .

[9]  J. Ho,et al.  A strip liposome immunoassay for aflatoxin B1. , 2002, Analytical chemistry.

[10]  R. R. Marquardt,et al.  Improved Methods for Conjugating Selected Mycotoxins to Carrier Proteins and Dextran for Immunoassays , 1995 .

[11]  N. Kaji,et al.  Application of IgY to sandwich enzyme-linked immunosorbent assays, lateral flow devices, and immunopillar chips for detecting staphylococcal enterotoxins in milk and dairy products. , 2013, Journal of microbiological methods.

[12]  Brendan O׳Farrell,et al.  Lateral Flow Technology for Field-Based Applications-Basics and Advanced Developments. , 2015, Topics in companion animal medicine.

[13]  Hervé Volland,et al.  A fluorescent immunochromatographic test using immunoliposomes for detecting microcystins and nodularins , 2010, Analytical and bioanalytical chemistry.

[14]  Anatoly V. Zherdev,et al.  Quantum-Dot-Based Immunochromatographic Assay for Total IgE in Human Serum , 2013, PloS one.

[15]  Haiyang Jiang,et al.  Development of a microsphere-based fluorescence immunochromatographic assay for monitoring lincomycin in milk, honey, beef, and swine urine. , 2014, Journal of agricultural and food chemistry.

[16]  C. Giromini,et al.  Mycotoxin Contamination in the EU Feed Supply Chain: A Focus on Cereal Byproducts , 2016, Toxins.

[17]  S. de Saeger,et al.  Multiplex lateral flow immunoassay for mycotoxin determination. , 2014, Analytical chemistry.

[18]  F. Yu,et al.  Sensitive competitive direct enzyme-linked immunosorbent assay and gold nanoparticle immunochromatographic strip for detecting aflatoxin M1 in milk , 2011 .

[19]  Han Zuilhof,et al.  Multiplex surface plasmon resonance biosensing and its transferability towards imaging nanoplasmonics for detection of mycotoxins in barley. , 2016, The Analyst.

[20]  Jian Wu,et al.  A Fast and Sensitive Quantitative Lateral Flow Immunoassay for Cry1Ab Based on a Novel Signal Amplification Conjugate , 2012, Sensors.

[21]  Z. Amzil,et al.  Exposure to the Paralytic Shellfish Toxin Producer Alexandrium catenella Increases the Susceptibility of the Oyster Crassostrea gigas to Pathogenic Vibrios , 2016, Toxins.

[22]  Liguang Xu,et al.  Fluorescent strip sensor for rapid determination of toxins. , 2011, Chemical communications.

[23]  Andrew Wang,et al.  Quantum-dot submicrobead-based immunochromatographic assay for quantitative and sensitive detection of zearalenone. , 2015, Talanta.

[24]  D. Thouvenot,et al.  Radioimmunoassay for Zearalenone and Zearalanol in Human Serum: Production, Properties, and Use of Porcine Antibodies , 1983, Applied and environmental microbiology.

[25]  R. Niessner,et al.  A comparison of horseradish peroxidase, gold nanoparticles and qantum dots as labels in non-instrumental gel-based immunoassay , 2011 .

[26]  D. Deforce,et al.  Heterologous screening of hybridomas for the development of broad-specific monoclonal antibodies against deoxynivalenol and its analogues , 2014 .

[27]  Rhona K. M. Smith,et al.  Commission Regulation (EC) No 773/2004 , 2015 .

[28]  C. J. Mirocha,et al.  Production of antibody against T-2 toxin , 1979, Applied and environmental microbiology.

[29]  D. Deforce,et al.  Application of a new anti-zearalenone monoclonal antibody in different immunoassay formats , 2009, Analytical and bioanalytical chemistry.

[30]  C. Larabell,et al.  Quantum dots as cellular probes. , 2005, Annual review of biomedical engineering.

[31]  Inge M. Wouters,et al.  Rapid detection of fungal α-amylase in the work environment with a lateral flow immunoassay , 2006 .

[32]  Qinggui Wang,et al.  Beauvericin, a Bioactive Compound Produced by Fungi: A Short Review , 2012, Molecules.

[33]  Lingling Wang,et al.  Development and comparison of immunochromatographic strips with three nanomaterial labels: Colloidal gold, nanogold-polyaniline-nanogold microspheres (GPGs) and colloidal carbon for visual detection of salbutamol. , 2016, Biosensors & bioelectronics.

[34]  Sarah De Saeger,et al.  Occurrence of mycotoxins in feed as analyzed by a multi-mycotoxin LC-MS/MS method. , 2010, Journal of agricultural and food chemistry.

[35]  I. Ruisanchez,et al.  Validation of qualitative analytical methods , 2004 .

[36]  Suxia Zhang,et al.  Determination of T-2 Toxin and HT-2 Toxin in Milk: A Comparison of Three Formats of Immunoassays , 2012 .