Performance Assessment of Colorimetric Devices on Dental Porcelains

The selection of an appropriate material that duplicates the appearance of natural tooth structure is very important in restorative dentistry. Photometric and colorimetric analysis techniques offer great potential as a tool for aiding in the duplication process. The degree to which these techniques will be useful depends on the accuracy and precision with which they can be applied to translucent as well as opaque surfaces. The purpose of this investigation was to evaluate the performance of three currently-available photometric devices. The performance capabilities of the instruments were tested on various shades of opaque and translucent dental porcelain surfaces. The performance tests were designed for evaluation of the accuracy and precision of the instrument relative to a well-studied reference instrument. CIELAB color difference metrics were used for the performance analysis. The results revealed that each of the photometric instruments evaluated was capable of producing color measurements with precision. However, the degree of accuracy with which the color measurements were made varied depending on the instrument used and the type of material surface being measured. A photo-electric tristimulus colorimeter showed the best overall performance on the porcelain surfaces, supporting its use as a valuable tool for evaluating color in dentistry.

[1]  R. Berns,et al.  Empirical modeling of systematic spectrophotometric errors , 1988 .

[2]  R. J. Goodkind,et al.  The conversion of Chromascan designations to CIE tristimulus values. , 1982, The Journal of prosthetic dentistry.

[3]  S. M. Jaeckel,et al.  Practical Instrumental Colour Quality Control ‐ The Hatra Experience , 1976 .

[4]  A. Robertson Colorimetric Significance of Spectrophotometric Errors , 1967 .

[5]  Fred W. Billmeyer,et al.  Assessment of Color‐Measuring Instruments , 1981 .

[6]  R. C. Sproull,et al.  Color matching in dentistry. Part III. Color control , 1974 .

[7]  F. Billmeyer,et al.  Principles of color technology , 1967 .

[8]  F. Billmeyer Precision of Color Measurement with the GE Spectrophotometer. I. Routine Industrial Performance , 1965 .

[9]  W. Johnston,et al.  Concentration additivity of kubelka-munk optical coefficients of porcelain mixtures , 1986 .

[10]  J A Sorensen,et al.  Improved color matching of metal-ceramic restorations. Part I: A systematic method for shade determination. , 1987, The Journal of prosthetic dentistry.

[11]  Rolf G. Kuehni,et al.  An Experiment in Visual Scaling of Small Color Differences* , 1979, Color Research & Application.

[12]  J. Sorensen,et al.  Improved color matching of metal ceramic restorations. Part II: Procedures for visual communication. , 1987, The Journal of prosthetic dentistry.

[13]  W M Johnston,et al.  Spectrophotometric analysis of color differences between porcelain systems. , 1986, The Journal of prosthetic dentistry.

[14]  F W Billmeyer,et al.  Comparative performance of color-measuring instruments; second report. , 1974, Applied optics.

[15]  Paul J. Muia,et al.  The four dimensional tooth color system , 1982 .

[16]  Fred W. Billmeyer,et al.  Comparative performance of color-measuring instruments. , 1969, Applied optics.

[17]  F. Billmeyer,et al.  Precision of Color Measurement with the GE Spectrophotometer. II: Photometric Accuracy. , 1969, Applied optics.

[18]  D. B. Judd,et al.  Color in Business, Science, and Industry , 1953 .

[19]  P. Kubelka Ein Beitrag zur Optik der Farban striche , 1931 .

[20]  F. Clarke,et al.  High Accuracy Spectrophotometry at the National Physical Laboratory. , 1972, Journal of research of the National Bureau of Standards. Section A, Physics and chemistry.