X-ray micro-tomography system for small-animal imaging with zoom-in imaging capability.

Since a micro-tomography system capable of microm-resolution imaging cannot be used for whole-body imaging of a small laboratory animal without sacrificing its spatial resolution, it is desirable for a micro-tomography system to have local imaging capability. In this paper, we introduce an x-ray micro-tomography system capable of high-resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest (ROI), we have obtained zoomed-in images of the ROI without any contrast anomalies commonly appearing in conventional local tomography. For experimental verification of the zoom-in imaging capability, we have integrated a micro-tomography system using a microfocus x-ray source, a 1248 x 1248 flat-panel x-ray detector, and a precision scan mechanism. The mismatches between the two projection data caused by misalignments of the scan mechanism have been estimated with a calibration phantom, and the mismatch effects have been compensated in the image reconstruction procedure. Zoom-in imaging results of bony tissues with a spatial resolution of 10 lp mm(-1) suggest that zoom-in micro-tomography can be greatly used for high-resolution imaging of a local region in small-animal studies.

[1]  Michael J. Paulus,et al.  High-resolution x-ray CT screening of mutant mouse models , 2000, Photonics West - Biomedical Optics.

[2]  E. Ritman,et al.  Molecular imaging in small animals—roles for micro‐CT , 2002, Journal of cellular biochemistry. Supplement.

[3]  A Fenster,et al.  A high-resolution XRII-based quantitative volume CT scanner. , 1993, Medical physics.

[4]  Gabor T. Herman,et al.  Image Reconstruction From Projections , 1975, Real Time Imaging.

[5]  Nicholas Pleace,et al.  The housing needs of disabled people. , 1998, Health & social care in the community.

[6]  Erik L. Ritman,et al.  Local tomography , 1992 .

[7]  S. Gambhir,et al.  Molecular imaging in living subjects: seeing fundamental biological processes in a new light. , 2003, Genes & development.

[8]  R. Müller,et al.  The effect of an osteolytic tumor on the three-dimensional trabecular bone morphology in an animal model , 2001, Skeletal Radiology.

[9]  R. Coatney,et al.  Applications of micro-CT and MR microscopy to study pre-clinical models of osteoporosis and osteoarthritis. , 1998, Technology and health care : official journal of the European Society for Engineering and Medicine.

[10]  Kennan T. Smith,et al.  Mathematical foundations of computed tomography. , 1985, Applied optics.

[11]  Min Hyoung Cho,et al.  A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging. , 2003, Physics in medicine and biology.

[12]  Paul J. Thomas,et al.  Local reconstruction applied to x-ray microtomography , 1997 .

[13]  Robert M. Sweet,et al.  Multiple CCD detector for macromolecular X-ray crystallography , 2000 .

[14]  M G Pomper,et al.  Molecular imaging: an overview. , 2001, Academic radiology.

[15]  Erik L. Ritman,et al.  Local Tomography II , 1997, SIAM J. Appl. Math..

[16]  J H Siewerdsen,et al.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization. , 2000, Medical physics.

[17]  W.E. Higgins,et al.  Extraction of the hepatic vasculature in rats using 3-D micro-CT images , 2000, IEEE Transactions on Medical Imaging.

[18]  Shaun S. Gleason,et al.  A new X-ray computed tomography system for laboratory mouse imaging , 1998 .

[19]  S M Jorgensen,et al.  Three-dimensional imaging of vasculature and parenchyma in intact rodent organs with X-ray micro-CT. , 1998, The American journal of physiology.

[20]  Kazuki Fujita,et al.  High resolution and high sensitivity CMOS panel sensors for X-ray imaging , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).