Histopathological correlation of corneal diseases with optical coherence tomography

AbstractPurpose. To correlate the cross-sectional images of corneal diseases obtained by optical coherence tomography (OCT) with light microscopy (LM) to determine the corneal components represented in OCT images. Methods. In a prospective comparative tissue study clinicopathological correlations of six patients with pseudophakic bullous keratopathy (n=3), advanced keratoconus (n=1), persistent epithelial defect with corneal thinning (n=1), and retrocorneal membrane (n=1) were included. Immediately before a planned penetrating keratoplasty (PKP) noncontact slitlamp-adapted OCT of the cornea was performed. After PKP and following standard histological processing the specimens were examined under LM to compare qualitatively the morphology, and quantitatively the morphometry at selected corneal locations. Results. The cross-sectional optical-reflectivity profiles enabled the reproducible morphological evaluation of the corneal structures and changes. Layers of relative high reflectivity corresponded to the anterior corneal surface and internal stromal layers. In contrast, the deeper corneal epithelial layer demonstrated relative low reflectivity by OCT. An increase in light reflectivity corresponded to corneal scarring, irregularities of the corneal lamellae, and deposition of basal membrane material. Low signal intensity was particularly due to fluid accumulations and shadowing. The most prominent changes were caused by corneal scars or edematous tissue. The morphometric analysis with OCT revealed, in this study, thickness measurements ranging from 31 to 902 µm. Although the mean OCT thickness values were up to 9% (P=0.014) higher than those derived from LM, there was a significant positive correlation (r=0.94; P<0.001) between corneal OCT and the light-microscopic measurements. Conclusion. Noncontact slitlamp-adapted corneal OCT revealed a good correlation with histological sections. The differences noted were partly related to shrinking processes during preparation. Thus, with certain limitations, OCT allows a non-invasive optical biopsy of pathological structures in corneal diseases.

[1]  J. Duker,et al.  Imaging of macular diseases with optical coherence tomography. , 1995, Ophthalmology.

[2]  J. Fujimoto,et al.  Optical biopsy and imaging using optical coherence tomography , 1995, Nature Medicine.

[3]  H. Laqua,et al.  Biomorphometrie des Hornhautepithels mittels spaltlampenadaptierter optischer Kohärenztomographie , 2001, Der Ophthalmologe.

[4]  J. Fujimoto,et al.  Micron‐resolution ranging of cornea anterior chamber by optical reflectometry , 1991, Lasers in surgery and medicine.

[5]  H F Edelhauser,et al.  Ultrastructure in anterior and posterior stroma of perfused human and rabbit corneas. Relation to transparency. , 1995, Investigative ophthalmology & visual science.

[6]  J. Fujimoto,et al.  Ultrahigh-resolution ophthalmic optical coherence tomography , 2001, Nature Medicine.

[7]  D. Pham,et al.  Corneal optical coherence tomography before and after phototherapeutic keratectomy for recurrent epithelial erosions , 2002, Journal of cataract and refractive surgery.

[8]  Harald Sattmann,et al.  Resolution-improved dual-beam and standard optical coherence tomography: a comparison , 2000, Graefe's Archive for Clinical and Experimental Ophthalmology.

[9]  A. Cideciyan,et al.  Relation of optical coherence tomography to microanatomy in normal and rd chickens. , 1998, Investigative ophthalmology & visual science.

[10]  R. Birngruber,et al.  Untersuchungen der Hornhaut mittels optischer Kohärenztomographie , 2001, Der Ophthalmologe.

[11]  R Birngruber,et al.  First experimental and clinical results with transscleral optical coherence tomography. , 2000, Ophthalmic surgery and lasers.

[12]  J. Fujimoto,et al.  Optical coherence tomography of the human retina. , 1995, Archives of ophthalmology.

[13]  D. Maurice The structure and transparency of the cornea , 1957, The Journal of physiology.

[14]  H. Ishikawa,et al.  Increasing sampling density improves reproducibility of optical coherence tomography measurements. , 1999, Journal of glaucoma.

[15]  D. Chauhan,et al.  The interpretation of optical coherence tomography images of the retina. , 1999, Investigative ophthalmology & visual science.

[16]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[17]  W M Bourne,et al.  Automated quantification of keratocyte density by using confocal microscopy in vivo. , 1999, Investigative ophthalmology & visual science.

[18]  R Birngruber,et al.  A comparison of retinal morphology viewed by optical coherence tomography and by light microscopy. , 1997, Archives of ophthalmology.

[19]  T Iwadare,et al.  Dimensional changes of tissues in the course of processing , 1984, Journal of microscopy.

[20]  Y Miyake,et al.  Optical Coherence Tomography for the Noninvasive Evaluation of the Cornea , 2001, Cornea.

[21]  T. Ushiki,et al.  The three-dimensional organization of collagen fibrils in the human cornea and sclera. , 1991, Investigative ophthalmology & visual science.

[22]  F. Fitzke,et al.  Refractive index of the human corneal epithelium and stroma. , 1995, Journal of refractive surgery.

[23]  N. Stickland,et al.  A detailed analysis of the effects of various fixatives on animal tissue with particular reference to muscle tissue. , 1975, Stain technology.

[24]  C K Hitzenberger,et al.  Interferometric measurement of corneal thickness with micrometer precision. , 1994, American journal of ophthalmology.

[25]  G. Vrensen,et al.  The specific architecture of the anterior stroma accounts for maintenance of corneal curvature , 2001, The British journal of ophthalmology.

[26]  D. Jabs,et al.  The architecture of the corneal stroma , 2001, The British journal of ophthalmology.

[27]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[28]  D. Reitze,et al.  Noninvasive imaging by optical coherence tomography to monitor retinal degeneration in the mouse. , 2001, Investigative ophthalmology & visual science.

[29]  C. Scholz,et al.  Corneal optical coherence tomography before and immediately after excimer laser photorefractive keratectomy. , 2000, American journal of ophthalmology.

[30]  E A Swanson,et al.  Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography. , 1994, Archives of ophthalmology.

[31]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[32]  J. Izatt,et al.  Real-time optical coherence tomography of the anterior segment at 1310 nm. , 2001, Archives of ophthalmology.

[33]  Reginald Birngruber,et al.  Noncontact corneal pachymetry with slit lamp-adapted optical coherence tomography. , 2002, American journal of ophthalmology.