Efficacy of a pulsed oxygen delivery device during exercise in patients with chronic respiratory disease.

The ability of a pulsed oxygen delivery system (Puritan-Bennett Companion Oxygen Saver (COS-5) to track respiratory rate during exercise and the oxygenation achieved during the exercise while oxygen was being delivered by this system was compared to that attained while oxygen was delivered continuously in six patients with chronic obstructive pulmonary disease (COPD) and six patients with idiopathic pulmonary fibrosis (IPF). The COS-5 appeared to respond appropriately at respiratory rates between 15 and 45, even when there were minimal pressure changes at the nose. There was an excellent correlation in PaO2 at equivalent flow settings during the exercise in the patients with COPD and IPF. There were six instances (in four patients) of the 31 comparisons in which the PaO2 differed by more than 5 mm Hg. The PaO2 was higher with continuous oxygen delivery on two occasions in a patient with COPD who utilized pursed-lip breathing during the exercise. The PaO2 was higher with COS-5 delivery on two occasions in a patient with IPF who was breathing at the highest respiratory rates (44 and 45/min) during the exercise.

[1]  J. S. Bower,et al.  Performance of a demand oxygen saver system during rest, exercise, and sleep in hypoxemic patients. , 1988, Chest.

[2]  J. McCormick,et al.  Corticosteroids in COPD. A clinical trial and reassessment of the literature. , 1986, Chest.

[3]  M. Littner,et al.  Conservation of oxygen supply using a reservoir nasal cannula in hypoxemic patients at rest and during exercise. , 1985, Chest.

[4]  Petty Tl Who needs home oxygen , 1985 .

[5]  M. Nicotra,et al.  Low-concentration oxygen therapy via a demand oxygen delivery system. , 1985, Chest.

[6]  M. Belman,et al.  A new pendant storage oxygen-conserving nasal cannula. , 1985, Chest.

[7]  T. Petty Who needs home oxygen? , 1985, The American review of respiratory disease.

[8]  D. Flenley Long-term home oxygen therapy. , 1985, Chest.

[9]  D. Geddes,et al.  INSPIRATION-PHASED OXYGEN DELIVERY , 1984, The Lancet.

[10]  M Mecikalski,et al.  A demand valve conserves oxygen in subjects with chronic obstructive pulmonary disease. , 1984, Chest.

[11]  M. Belman,et al.  Evaluation of a low-flow oxygen-conserving nasal cannula. , 1984, The American review of respiratory disease.

[12]  P. Howard Clinical experience with the oxygen concentrator , 1983, British medical journal.

[13]  D. Auerbach,et al.  A new oxygen cannula system using intermittent-demand nasal flow. , 1978, Chest.

[14]  A G Leitch,et al.  Long-term domiciliary oxygen therapy in cor pulmonale complicating chronic bronchitis and emphysema. , 1976, Thorax.