Turbulent heat transfer enhancement in a heat exchanger using helically corrugated tube

Abstract The augmentation of convective heat transfer in a single-phase turbulent flow by using helically corrugated tubes has been experimentally investigated. Effects of pitch-to-diameter ratio (P/DH = 0.18, 0.22 and 0.27) and rib-height to diameter ratio (e/DH = 0.02, 0.04 and 0.06) of helically corrugated tubes on the heat transfer enhancement, isothermal friction and thermal performance factor in a concentric tube heat exchanger are examined. The experiments were conducted over a wide range of turbulent fluid flow of Reynolds number from 5500 to 60,000 by employing water as the test fluid. Experimental results show that the heat transfer and thermal performance of the corrugated tube are considerably increased compared to those of the smooth tube. The mean increase in heat transfer rate is between 123% and 232% at the test range, depending on the rib height/pitch ratios and Reynolds number while the maximum thermal performance is found to be about 2.3 for using the corrugated tube with P/DH = 0.27 and e/DH = 0.06 at low Reynolds number. Also, the pressure loss result reveals that the average friction factor of the corrugated tube is in a range between 1.46 and 1.93 times over the smooth tube. In addition, correlations of the Nusselt number, friction factor and thermal performance factor in terms of pitch ratio (P/DH), rib-height ratio (e/DH), Reynolds number (Re), and Prandtl number (Pr) for the corrugated tube are determined, based on the curve fitting of the experimental data.

[1]  S. F. Al-Fahed,et al.  Pressure drop and heat transfer comparison for both microfin tube and twisted-tape inserts in laminar flow , 1998 .

[2]  V. Zimparov Prediction of friction factors and heat transfer coefficients for turbulent flow in corrugated tubes combined with twisted tape inserts. Part 2: heat transfer coefficients , 2004 .

[3]  Lixian Zhuang,et al.  Heat transfer characteristics of carbon steel spirally fluted tube for high pressure preheaters , 2000 .

[4]  G. P. Greyvenstein,et al.  Detailed Simulation of Fluted Tube Water Heating Condensers , 2003 .

[5]  V. Zimparov,et al.  Prediction of friction factors and heat transfer coefficients for turbulent flow in corrugated tubes combined with twisted tape inserts. Part 1: friction factors , 2004 .

[6]  Ralph L. Webb,et al.  Heat transfer and friction characteristics of internal helical-rib roughness , 2000 .

[7]  P. G. Vicente,et al.  Experimental investigation on heat transfer and frictional characteristics of spirally corrugated tubes in turbulent flow at different Prandtl numbers , 2004 .

[8]  Huixiong Li,et al.  Pressure drop, heat transfer and performance of single-phase turbulent flow in spirally corrugated tubes , 2001 .

[9]  Somchai Wongwises,et al.  The effects of corrugation pitch on the condensation heat transfer coefficient and pressure drop of R-134a inside horizontal corrugated tube , 2010 .

[10]  X. Hong,et al.  Numerical heat transfer analysis of laminar film condensation on a vertical fluted tube , 2010 .

[11]  Marco Spiga,et al.  HEAT TRANSFER ENHANCEMENT IN A CORRUGATED TUBE , 2002 .

[12]  A. Trifirò,et al.  Heat treatment of fluid foods in a shell and tube heat exchanger: Comparison between smooth and helically corrugated wall tubes , 2007 .

[13]  Sara Rainieri,et al.  Convective heat transfer to temperature dependent property fluids in the entry region of corrugated tubes , 2002 .

[14]  Yong Tae Kang,et al.  The effects of inclination angle on flooding in a helically fluted tube with a twisted insert , 1997 .

[15]  J. L. Zakin,et al.  Enhanced heat transfer of drag reducing surfactant solutions with fluted tube-in-tube heat exchanger , 2001 .

[16]  XinGang Liang,et al.  Experimental study on convective heat transfer in alternating elliptical axis tubes , 2005 .

[17]  P. G. Vicente,et al.  MIXED CONVECTION HEAT TRANSFER AND ISOTHERMAL PRESSURE DROP IN CORRUGATED TUBES FOR LAMINAR AND TRANSITION FLOW , 2004 .

[18]  Y. Jaluria,et al.  An Introduction to Heat Transfer , 1950 .

[19]  Fang Xiaoming,et al.  Experimental study on heat transfer enhancement of a helically baffled heat exchanger combined with three-dimensional finned tubes , 2004 .