Abdominal-Lead Fetal Electrocardiographic R-Wave Enhancement for Heart Rate Determination

The reliability of fetal heart rate (FHR) from external abdominal-lead electrocardiographic waveforms depends upon the R-wave detection capability of the monitoring device. Assuming that the maternal component of the ECG is canceiled by techniques described elsewhere [1]-[4], we are left with a fetal electrocardiogm (FECG) which may be conrupted by high noise levels. This paper describes several digital signal processing techniques by which the detection of fetal R-waves is improved. These techniques-narrow band-pass filtering, local peak differencing, autoregressive filtering, and matched filtering-are theoretically developed. The performance of each technique is measured and analyzed for two sample fetal ECG inputs.

[1]  R L Longini,et al.  A noninvasive extraction of the fetal electrocardiogram. , 1977, Computers and biomedical research, an international journal.

[2]  A. Favret,et al.  Fetal Electrocardiographic Wave Forms from Abdominal‐Wall Recordings , 1966, Obstetrics and gynecology.

[3]  G. Corner,et al.  A fetal heart ratemeter. , 1957, American journal of obstetrics and gynecology.

[4]  Favret Ag,et al.  Fetal electrocardiographic wave forms from abdominal-wall recordings. , 1966 .

[5]  J. .. Bemmel,et al.  Detection Procedure to Represent the Foetal Heart Rate and Electrocardiogram , 1966 .

[6]  B. Widrow,et al.  Adaptive noise cancelling: Principles and applications , 1975 .

[7]  J. Makhoul,et al.  Linear prediction: A tutorial review , 1975, Proceedings of the IEEE.

[8]  G. Turin,et al.  An introduction to matched filters , 1960, IRE Trans. Inf. Theory.

[9]  R. L. Longini,et al.  Near-Orthogonal Basis Functions: A Real Time Fetal ECG Technique , 1977, IEEE Transactions on Biomedical Engineering.

[10]  G. Bodenstein,et al.  Feature extraction from the electroencephalogram by adaptive segmentation , 1977, Proceedings of the IEEE.

[11]  Allan R. Hambley,et al.  The Use of Intrinsic Components in an ECG Filter , 1974 .

[12]  H. G. Goovaerts,et al.  A Digital QRS Detector Based on the Principle of Contour Limiting , 1976, IEEE Transactions on Biomedical Engineering.

[13]  H M Praetorius,et al.  Adaptive segmentation of EEG records: a new approach to automatic EEG analysis. , 1977, Electroencephalography and clinical neurophysiology.

[14]  Kenneth M. Kempner,et al.  A QRS Preprocessor Based on Digital Differentiation , 1971 .

[15]  R. J. Twizell A noise-protected digital heart ratemeter , 1975 .