Analysis of the Applicability of PMU Measurements for Power Quality Assessment

This paper presents the results of the study made to analyse the applicability of PMU measurements for power quality (PQ) assessment. Using PMUs to assess the PQ in the power system is becoming more relevant in context of increasing level of power electronic devices in the grid, e.g. HVDC, FACTS, wind and solar power plants, etc., and due to increasing installations and use of PMU measurements. For this study, several test cases were developed and assessments were made based on criteria defined in the IEEE standard C37.118.1-2011. Three PMU units form different manufacturers were tested and the results are presented in the paper. The results indicate that PMU data is suitable for some indicative steady-state PQ assessment. However, assessment of higher harmonics should be done with PMUs that have special modules or estimation algorithms for this kind of purpose.

[1]  J. Cepeda,et al.  Cenace's experiences on implementing a wide area monitoring system (WAMS) in the Ecuadorian power system , 2014, 2014 IEEE Central America and Panama Convention (CONCAPAN XXXIV).

[2]  E.M. Martinez Wide area measurement & control system in Mexico , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[3]  W.A. Mittelstadt,et al.  Use of the WECC WAMS in Wide-Area Probing Tests for Validation of System Performance and Modeling , 2009, IEEE Transactions on Power Systems.

[4]  Lang Tong,et al.  PMU-Based Detection of Imbalance in Three-Phase Power Systems , 2014, IEEE Transactions on Power Systems.

[5]  Martin Valtierra-Rodriguez,et al.  A scheme based on PMU data for power quality disturbances monitoring , 2017, IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society.

[6]  J.-C. Maun,et al.  Voltage-Stability Monitoring Using Wide-Area Measurement Systems , 2007, 2007 IEEE Lausanne Power Tech.

[7]  Zhiying Zhang,et al.  Calibration and testing of TESLA Phasor Measurement Unit (PMU) using doble F6150 test instrument , 2007, 2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability.

[8]  M. N. Agostini,et al.  Analysis and simulation of dynamic performance of PMU according to IEEE C37.118.1-2011 standard , 2016, 2016 IEEE/PES Transmission and Distribution Conference and Exposition (T&D).

[9]  W. Pimjaipong L. Surapongpun Wide Area Monitoring System - Planning, Strategy and Implementation in Thailand's Power Grid , 2013 .

[10]  Jako Kilter,et al.  Assessment of higher harmonics influence to PMU measurement accuracy , 2017, 2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe).

[11]  Qiuwei Wu,et al.  Steady-state PMU compliance test under C37.118.1a™-2014 , 2016, 2016 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe).

[12]  Dinesh Rangana Gurusinghe,et al.  Testing and Enhancement of the Dynamic Performance of a Phasor Measurement Unit , 2014, IEEE Transactions on Power Delivery.

[13]  A.G. Phadke,et al.  Wide Area Protection—Technology and Infrastructures , 2006, IEEE Transactions on Power Delivery.

[14]  Paolo Attilio Pegoraro,et al.  Phasor measurement units performance in three-phase unbalanced systems , 2017, 2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[15]  Cheng Lin,et al.  Steady-state PMU compliance test under C37.118.1aTM-2014 , 2016 .

[16]  J.F. Hauer,et al.  PMU Testing and Installation Considerations at the Bonneville Power Administration , 2007, 2007 IEEE Power Engineering Society General Meeting.

[17]  Dario Petri,et al.  Performance of Phasor Measurement Units for power quality event detection in urban distribution grids , 2016, 2016 IEEE International Smart Cities Conference (ISC2).

[18]  Luigi Vanfretti,et al.  Experiences with dynamic PMU compliance testing using standard relay testing equipment , 2015, 2015 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT).

[19]  Tianshu Bi,et al.  PMUs performance testing and evaluation in China , 2014, 2014 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC).

[20]  Lang Tong,et al.  PMU-Based Detection of Voltage Imbalances with Tolerance Constraints , 2017, IEEE Transactions on Power Delivery.

[21]  Luigi Vanfretti,et al.  Experiences with steady-state PMU compliance testing using standard relay testing equipment , 2014, 2014 Electric Power Quality and Supply Reliability Conference (PQ).

[22]  A.G. Phadke,et al.  The Wide World of Wide-area Measurement , 2008, IEEE Power and Energy Magazine.

[23]  Z.A. Styczynski,et al.  Practical Experience with PMU System Testing and Calibration Requirements , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[24]  Zhenyu Huang,et al.  Evaluation of PMU Dynamic Performance in Both Lab Environments and under Field Operating Conditions , 2007, 2007 IEEE Power Engineering Society General Meeting.

[25]  Yusheng Xue,et al.  Some viewpoints and experiences on wide area measurement systems and wide area control systems , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[26]  William H. Sanders,et al.  Enhancing Grid Measurements: Wide Area Measurement Systems, NASPInet, and Security , 2012, IEEE Power and Energy Magazine.

[27]  Lang Tong,et al.  Local detection of voltage imbalance in three-phase power systems based on PMU output , 2015, 2015 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT).