Virtual flux based direct power control of a three-phase rectifier connected to an LCL filter with sensorless active damping

This paper proposes a simple method for connecting an LCL filter to a three-phase pulse-width modulation (PWM) rectifier with direct power control space vector modulation (DPC-SVM) strategy. The goal is to improve the transient response and reduce the harmonic distortion, as well as size and cost reduction of the input filter. Since the proposed method is sensorless, the AC line voltage sensors are eliminated and the virtual flux block would be used instead. The cost and size of the filter could be reduced since the LCL-filter has lower inductance values and also the harmonic distortions could be reduced as well. The only drawback of the LCL-filter is producing resonance oscillations due to the resonance frequency of its third-order transfer function. In order to eliminate the oscillations, a simple method of active damping is utilized. Finally, simulation results have shown an excellent dynamic response compared with a three-phase converter that uses a conventional L-filter.

[1]  M. Liserre,et al.  Genetic algorithm-based design of the active damping for an LCL-filter three-phase active rectifier , 2003, IEEE Transactions on Power Electronics.

[2]  J.W. Kolar,et al.  A modified direct power control strategy allowing the connection of three-phase inverter to the grid through LCL filters , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[3]  Marian P. Kazmierkowski,et al.  Simple direct power control of three-phase PWM rectifier using space-vector modulation (DPC-SVM) , 2004, IEEE Transactions on Industrial Electronics.

[4]  Marian P. Kazmierkowski,et al.  Review and comparative study of control techniques for three-phase PWM rectifiers , 2003, Math. Comput. Simul..

[5]  Mariusz Malinowski,et al.  A Simple Voltage Sensorless Active Damping Scheme for Three-Phase PWM Converters With an $LCL$ Filter , 2008, IEEE Transactions on Industrial Electronics.

[6]  M. Safiuddin,et al.  Magnitude and symmetric optimum criterion for the design of linear control systems-what is it and does it compare with the others? , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[7]  Guozhu Chen,et al.  Comparison of active and passive damping methods for application in high power active power filter with LCL-filter , 2009, 2009 International Conference on Sustainable Power Generation and Supply.

[8]  J.W. Kolar,et al.  A Modified Direct Power Control Strategy Allowing the Connection of Three-Phase Inverters to the Grid Through $LCL$ Filters , 2005, IEEE Transactions on Industry Applications.

[9]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[10]  Frede Blaabjerg,et al.  A New Design Method for the Passive Damped LCL and LLCL Filter-Based Single-Phase Grid-Tied Inverter , 2013, IEEE Transactions on Industrial Electronics.

[11]  M. Liserre,et al.  Analysis of the Passive Damping Losses in LCL-Filter-Based Grid Converters , 2013, IEEE Transactions on Power Electronics.

[12]  P.A. Dahono A control method for DC-DC converter that has an LCL output filter based on new virtual capacitor and resistor concepts , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[13]  Mariusz Malinowski,et al.  Virtual flux based direct power control of three-phase PWM rectifiers , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[14]  Mariusz Malinowski,et al.  Sensorless Control Strategies for Three - Phase PWM Rectifiers , 2001 .

[15]  Toshihiko Noguchi,et al.  Direct power control of PWM converter without power source voltage sensors , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[16]  V. Blasko,et al.  A novel control to actively damp resonance in input LC filter of a three phase voltage source converter , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[17]  Arkadiusz Kulka,et al.  Sensorless Digital Control of Grid Connected Three Phase Converters for Renewable Sources , 2008 .