Fully automatic detection of salient features in 3-d transesophageal images.

Most automated segmentation approaches to the mitral valve and left ventricle in 3-D echocardiography require a manual initialization. In this article, we propose a fully automatic scheme to initialize a multicavity segmentation approach in 3-D transesophageal echocardiography by detecting the left ventricle long axis, the mitral valve and the aortic valve location. Our approach uses a probabilistic and structural tissue classification to find structures such as the mitral and aortic valves; the Hough transform for circles to find the center of the left ventricle; and multidimensional dynamic programming to find the best position for the left ventricle long axis. For accuracy and agreement assessment, the proposed method was evaluated in 19 patients with respect to manual landmarks and as initialization of a multicavity segmentation approach for the left ventricle, the right ventricle, the left atrium, the right atrium and the aorta. The segmentation results revealed no statistically significant differences between manual and automated initialization in a paired t-test (p > 0.05). Additionally, small biases between manual and automated initialization were detected in the Bland-Altman analysis (bias, variance) for the left ventricle (-0.04, 0.10); right ventricle (-0.07, 0.18); left atrium (-0.01, 0.03); right atrium (-0.04, 0.13); and aorta (-0.05, 0.14). These results indicate that the proposed approach provides robust and accurate detection to initialize a multicavity segmentation approach without any user interaction.

[1]  Anil K. Jain,et al.  Deformable template models: A review , 1998, Signal Process..

[2]  William Stanford,et al.  The fuzzy Hough transform-feature extraction in medical images , 1994, IEEE Trans. Medical Imaging.

[3]  Siew Yen Ho,et al.  Structure and anatomy of the aortic root. , 2009, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[4]  Attila Nemes,et al.  A Comparison between QLAB and TomTec Full Volume Reconstruction for Real Time Three‐Dimensional Echocardiographic Quantification of Left Ventricular Volumes , 2007, Echocardiography.

[5]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[6]  Daniel DeMenthon,et al.  Patient-specific mitral valve closure prediction using 3D echocardiography. , 2013, Ultrasound in medicine & biology.

[7]  J H C Reiber,et al.  Time continuous detection of the left ventricular long axis and the mitral valve plane in 3-D echocardiography. , 2008, Ultrasound in medicine & biology.

[8]  J. A. Hartigan,et al.  A k-means clustering algorithm , 1979 .

[9]  Philippe Acar,et al.  Assessment of Left Ventricular Volumes and Function by Real Time Three‐Dimensional Echocardiography in a Pediatric Population: A TomTec versus QLAB Comparison , 2010, Echocardiography.

[10]  Eduardo Moreno,et al.  Three-dimensional versus two-dimensional transesophageal echocardiography in mitral valve repair. , 2007, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[11]  Milan Sonka,et al.  Multistage hybrid active appearance model matching: segmentation of left and right ventricles in cardiac MR images , 2001, IEEE Transactions on Medical Imaging.

[12]  Caroline Petitjean,et al.  A review of segmentation methods in short axis cardiac MR images , 2011, Medical Image Anal..

[13]  Carl-Fredrik Westin,et al.  Tissue Classification Based on 3D Local Intensity Structures for Volume Rendering , 2000, IEEE Trans. Vis. Comput. Graph..

[14]  M. Simoons,et al.  Real-time transthoracic three-dimensional echocardiographic assessment of left ventricular volume and ejection fraction in congenital heart disease. , 2006, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[15]  Robert D. Howe,et al.  Mitral Annulus Segmentation From 3D Ultrasound Using Graph Cuts , 2010, IEEE Transactions on Medical Imaging.

[16]  Eran Toledo,et al.  Evaluation of left ventricular systolic function using automated angle-independent motion tracking of mitral annular displacement. , 2005, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[17]  Santiago Aja-Fernández,et al.  Speckle Tracking in Interpolated Echocardiography to Estimate Heart Motion , 2013, FIMH.

[18]  Y. Shimada,et al.  A meta-analysis and investigation for the source of bias of left ventricular volumes and function by three-dimensional echocardiography in comparison with magnetic resonance imaging. , 2011, The American journal of cardiology.

[19]  Denisa Muraru,et al.  Validation of a novel automated border-detection algorithm for rapid and accurate quantitation of left ventricular volumes based on three-dimensional echocardiography. , 2010, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[20]  N. Nanda,et al.  Usefulness of Transesophageal Three‐Dimensional Echocardiography in the Identification of Individual Segment/Scallop Prolapse of the Mitral Valve , 2003, Echocardiography.

[21]  Jerry L Prince,et al.  Current methods in medical image segmentation. , 2000, Annual review of biomedical engineering.

[22]  Boudewijn P. F. Lelieveldt,et al.  Time Continuous Tracking and Segmentation of Cardiovascular Magnetic Resonance Images Using Multidimensional Dynamic Programming , 2006, Investigative radiology.

[23]  R. Haralick,et al.  The Topographic Primal Sketch , 1983 .

[24]  Livia Kapusta,et al.  Modeling envelope statistics of blood and myocardium for segmentation of echocardiographic images. , 2008, Ultrasound in medicine & biology.

[25]  Hervé Delingette,et al.  Functional Imaging and Modeling of the Heart, 5th International Conference, FIMH 2009, Nice, France, June 3-5, 2009. Proceedings , 2009, Functional Imaging and Modeling of the Heart.

[26]  Agnes Pasquet,et al.  Recommendations for transoesophageal echocardiography: update 2010. , 2010, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[27]  Ken Masamune,et al.  Augmented Reality Environments for Medical Imaging and Computer-Assisted Interventions , 2013, Lecture Notes in Computer Science.

[28]  Cesar Palencia,et al.  A Generalized Gamma Mixture Model for Ultrasonic Tissue Characterization , 2012, Comput. Math. Methods Medicine.

[29]  Marius George Linguraru,et al.  Statistical segmentation of surgical instruments in 3-D ultrasound images. , 2007, Ultrasound in medicine & biology.

[30]  B. Segal,et al.  Symposium on echocardiography (diagnostic ultrasound). Introduction. Echocardiography--Ultrasoundcardiography. , 1967, The American journal of cardiology.

[31]  A. Tajik,et al.  Age-related changes in aortic and mitral valve thickness: implications for two-dimensional echocardiography based on an autopsy study of 200 normal human hearts. , 1988, The American journal of cardiology.

[32]  J. Sethian,et al.  Fronts propagating with curvature-dependent speed: algorithms based on Hamilton-Jacobi formulations , 1988 .

[33]  Eiji Toyota,et al.  Quantitation of mitral valve tenting in ischemic mitral regurgitation by transthoracic real-time three-dimensional echocardiography. , 2005, Journal of the American College of Cardiology.

[34]  J. Reiber,et al.  Comparison between manual and semiautomated analysis of left ventricular volume parameters from short-axis MR images. , 1997, Journal of computer assisted tomography.

[35]  Timothy F. Cootes,et al.  Active Shape Models-Their Training and Application , 1995, Comput. Vis. Image Underst..

[36]  F J Ten Cate,et al.  Three-dimensional echocardiography of normal and pathologic mitral valve: a comparison with two-dimensional transesophageal echocardiography. , 1996, Journal of the American College of Cardiology.

[37]  Guido Gerig,et al.  Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images , 1998, Medical Image Anal..

[38]  D. O’Regan,et al.  Right ventricular remodelling in pulmonary arterial hypertension with three-dimensional echocardiography: comparison with cardiac magnetic resonance imaging. , 2010, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[39]  R. F. Wagner,et al.  Statistics of Speckle in Ultrasound B-Scans , 1983, IEEE Transactions on Sonics and Ultrasonics.

[40]  Dana H. Ballard,et al.  Generalizing the Hough transform to detect arbitrary shapes , 1981, Pattern Recognit..

[41]  Denis Friboulet,et al.  Fast and fully automatic 3-d echocardiographic segmentation using B-spline explicit active surfaces: feasibility study and validation in a clinical setting. , 2013, Ultrasound in medicine & biology.

[42]  Demetri Terzopoulos,et al.  Snakes: Active contour models , 2004, International Journal of Computer Vision.

[43]  Victor Mor-Avi,et al.  Age and body surface area dependency of mitral valve and papillary apparatus parameters: assessment by real-time three-dimensional echocardiography. , 2009, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[44]  Marcos Martin-Fernandez,et al.  Gamma mixture classifier for plaque detection in intravascular ultrasonic images , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[45]  Timothy F. Cootes,et al.  Active Appearance Models , 2001, IEEE Trans. Pattern Anal. Mach. Intell..

[46]  Timoteo Carletti,et al.  The Stochastic Evolution of a Protocell: The Gillespie Algorithm in a Dynamically Varying Volume , 2011, Comput. Math. Methods Medicine.

[47]  T. Moon The expectation-maximization algorithm , 1996, IEEE Signal Process. Mag..

[48]  Paul A. Yushkevich,et al.  Fully automatic segmentation of the mitral leaflets in 3D transesophageal echocardiographic images using multi-atlas joint label fusion and deformable medial modeling , 2014, Medical Image Anal..