Reproducibility of scan prescription in follow-up brain MRI: manual versus automatic determination

In follow-up brain magnetic resonance imaging (MRI), precise reproducibility of the scan prescription is important so that over- or underestimating changes in volumes of clinical interest is prevented. (The scan prescription is defined as the location and orientation of the head with respect to the scan planes of the three-dimensional MRI matrix.) In this study, the misregistration between the original and a second scan was calculated in the case of both manual positioning and automatic positioning. These calculations were carried out both for a healthy volunteer scanned repeatedly and, in a retrospective study, for 225 patients who had an original and at least one follow-up scan. The effects of the scan operator being the same for both scans or being different were also examined. A commercially available 1.5 Tesla MRI system and a six-element head-array coil were employed in all of the imaging. The reproducibility of the scan prescription was determined by the registration of the original scan image to the follow-up scan image by use of the Fourier phase correlation method. Our results showed that (1) the reproducibility by automatic positioning was superior to that by manual positioning (p < 0.05), and (2) there was no significant difference in the results between when the operator was the same or different (p > 0.05). We conclude that, in follow-up brain MRI, automatic positioning should be used, because manual positioning decreases the reproducibility of the scan prescription even if the same operator performs the second scan.

[1]  R. Kikinis,et al.  Quantitative follow‐up of patients with multiple sclerosis using MRI: Technical aspects , 1999, Journal of magnetic resonance imaging : JMRI.

[2]  Daniel Bystrov,et al.  Pre‐ and postoperative MR brain imaging with automatic planning and scanning software in tumor patients: An intraindividual comparative study at 3 Tesla , 2009, Journal of magnetic resonance imaging : JMRI.

[3]  Marco Rovaris,et al.  The effect of repositioning on brain MRI lesion load assessment in multiple sclerosis: reliability of subjective quality criteria , 1998, Journal of Neurology.

[4]  Armando Manduca,et al.  Interscan registration using navigator echoes , 2004, Magnetic resonance in medicine.

[5]  Hassan Foroosh,et al.  Extension of phase correlation to subpixel registration , 2002, IEEE Trans. Image Process..

[6]  Anders M. Dale,et al.  On-line automatic slice positioning for brain MR imaging , 2005, NeuroImage.

[7]  Johannes Bernarding,et al.  Prospective registration of human head magnetic resonance images for reproducible slice positioning using localizer images , 2004, Journal of magnetic resonance imaging : JMRI.

[8]  John A. Nelder,et al.  A Simplex Method for Function Minimization , 1965, Comput. J..

[9]  Jan Flusser,et al.  3D Rigid registration by cylindrical phase correlation method , 2009, Pattern Recognit. Lett..

[10]  Y. Keller,et al.  Volume Registration Using the 3-D Pseudopolar Fourier Transform , 2006, IEEE Transactions on Signal Processing.

[11]  L. Clarke,et al.  Monitoring brain tumor response to therapy using MRI segmentation. , 1997, Magnetic resonance imaging.

[12]  Frederik Barkhof,et al.  Magnetic resonance image registration in multiple sclerosis: Comparison with repositioning error and observer‐based variability , 2002, Journal of magnetic resonance imaging : JMRI.

[13]  L. Clarke,et al.  MRI measurement of brain tumor response: comparison of visual metric and automatic segmentation. , 1998, Magnetic resonance imaging.

[14]  William Scott Hoge,et al.  A subspace identification extension to the phase correlation method [MRI application] , 2003, IEEE Transactions on Medical Imaging.

[15]  Bruce Fischl,et al.  Comparison of manual and automatic section positioning of brain MR images. , 2006, Radiology.

[16]  R. Killiany,et al.  Quantitative follow‐up of patients with multiple sclerosis using MRI: Reproducibility , 1999, Journal of magnetic resonance imaging : JMRI.

[17]  B. N. Chatterji,et al.  An FFT-based technique for translation, rotation, and scale-invariant image registration , 1996, IEEE Trans. Image Process..

[18]  Automatic scan prescription for brain MRI , 2001, Magnetic resonance in medicine.

[19]  J H Simon,et al.  Computerized method of lesion volume quantitation in multiple sclerosis: error of serial studies. , 1997, AJNR. American journal of neuroradiology.