Effects of Lead-Free Solders on Flex Performance
暂无分享,去创建一个
Ceramic capacitors have proven themselves very reliable with extremely low failure rates. As processes continue to improve, reliability of the dielectric also continues to increase. This increase in the reliability of the dielectric has caused other categories to emerge as the main contributors to the overall failure rate. A recent review of field failure analysis of surface mount MLCCs, has shown Flex Cracks account for as much as 40% of ceramic capacitors failures. Flex Cracks are created when a physical displacement of the board mounted MLCC generates sufficient stress within the ceramic body to fracture the ceramic material. As the industry moves to lead free soldering systems, which are less ductile, there is a concern about the effects on flex performance. This paper was written in response to customer concerns of flex performance as they switch from lead based to lead free soldering processes. In this paper we present the results of flex testing, comparing standard lead based solders to lead free solders. Preparation of samples
[1] J. D. Prymak,et al. Capacitance monitoring while flex testing , 1994 .