Is a Wiggling-Motion Modified Two-Step Impression Technique as Accurate as Conventional Techniques in Restorative Dentistry?

Background: The purpose of this study was to evaluate dental impression accuracy of one-step and two-step techniques compared to a modified two-step technique. Methods: Four impression techniques were compared: (1) a one-step double mix (DM) technique, (2) a cut-out (CO) technique, in which space relief was created using a blade and a laboratory bur, (3) a membrane (ME) technique, in which space relief was created by placing a PVC membrane on top of the putty material during the primary impression, and (4) a wiggling motion (WI) technique, in which PVC membrane was placed and additional wiggling movements were performed during the first 20 s when the primary impression was seated upon the master model (MM). Impressions were poured with type IV stone. Casts were scanned with a laboratory scanner and measurements were made for each cast using three-dimensional analysis software. Results: All groups presented differences compared to MM group, in at least one intra-abutment distance. Groups DM and ME presented the most significant differences, in three and two distances, respectively, whereas CO and WI presented one significant different distance compared to MM. There were no differences between MM and the four techniques for inter-abutment distances. Conclusions: WI yielded similar results with CO technique. Both performed better than the other groups.

[1]  S. Jayalakshmi,et al.  Effect of disinfectants on the tear strength of addition silicone impression material – An in vitro study , 2022, Journal of advanced pharmaceutical technology & research.

[2]  H. Parize,et al.  Digital versus conventional workflow for the fabrication of physical casts for fixed prosthodontics: A systematic review of accuracy. , 2021, The Journal of prosthetic dentistry.

[3]  V. Malvezzi,et al.  Comparative surface detail reproduction for elastomeric impression materials: Study on reproducibility performance. , 2021, Journal of biological regulators and homeostatic agents.

[4]  I. Garcia,et al.  Dimensional stability of full arch impressions after disinfection using 3D cone-beam CT image assessment , 2020 .

[5]  Tushar,et al.  Comparison and Evaluation of Linear Dimensional Accuracy of Three Elastomeric Impression Materials at Different Time Intervals Using Vision Inspection System: An In Vitro Study , 2020, Journal of International Society of Preventive & Community Dentistry.

[6]  J. Hardouin,et al.  Comparative assessment of complete-coverage, fixed tooth-supported prostheses fabricated from digital scans or conventional impressions: A systematic review and meta-analysis. , 2020, The Journal of prosthetic dentistry.

[7]  J. Nissan,et al.  Influence of Vinyl Polysiloxane Impression Techniques on Marginal Fit of Metal Frameworks for Fixed Partial Dentures , 2020, Materials.

[8]  Vikram M Belkhode,et al.  Comparative Evaluation of the Effect of Chemical Disinfectants and Ultraviolet Disinfection on Dimensional Stability of the Polyvinyl Siloxane Impressions , 2019, Journal of International Society of Preventive & Community Dentistry.

[9]  Alper Çağlar,et al.  3D evaluation of the effect of disinfectants on dimensional accuracy and stability of two elastomeric impression materials. , 2018, Dental materials journal.

[10]  Borjan Naumovski,et al.  Dimensional Stability and Accuracy of Silicone – Based Impression Materials Using Different Impression Techniques – A Literature Review , 2017, Prilozi.

[11]  R. Weiger,et al.  Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique , 2017, The journal of advanced prosthodontics.

[12]  R. D. de Souza,et al.  Accuracy of Gypsum Casts after Different Impression Techniques and Double Pouring , 2016, PloS one.

[13]  Sreeramulu Basapogu,et al.  Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro Study. , 2016, Journal of clinical and diagnostic research : JCDR.

[14]  Suresh S. Kamble,et al.  Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection , 2015, Journal of international oral health : JIOH.

[15]  U. Range,et al.  Experimental study on the use of spacer foils in two-step putty and wash impression procedures using silicone impression materials. , 2015, The Journal of prosthetic dentistry.

[16]  S. Caputi,et al.  Evaluation of defects in surface detail for monophase, 2-phase, and 3-phase impression techniques: an in vitro study. , 2015, The Journal of prosthetic dentistry.

[17]  Suresh S. Kamble,et al.  Evaluation of Different Disinfactants on Dimensional Accuracy and Surface Quality of Type IV Gypsum Casts Retrieved from Elastomeric Impression Materials. , 2014, Journal of international oral health : JIOH.

[18]  M. Robb,et al.  The effect of one-step vs. two-step impression techniques on long-term accuracy and dimensional stability when the finish line is within the gingival sulcular area , 2014, BDJ.

[19]  Ramandeep Dugal,et al.  Comparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study. , 2013, Journal of international oral health : JIOH.

[20]  R. Consani,et al.  Dimensional accuracy of stone casts made from silicone-based impression materials and three impression techniques. , 2013, Brazilian dental journal.

[21]  V. Chitre,et al.  A Comparative Evaluation of the Linear Dimensional Accuracy of Four Impression Techniques using Polyether Impression Material , 2013, Journal of Indian Prosthodontic Society.

[22]  G. Levy,et al.  Dimensional stability of polyvinyl siloxane impression material reproducing the sulcular area. , 2013, Dental materials journal.

[23]  N. Pande,et al.  An Evaluation of Dimensional Accuracy of One-Step and Two-Step Impression Technique Using Addition Silicone Impression Material: An In Vitro Study , 2012, Journal of Indian Prosthodontic Society.

[24]  Anshul Chugh,et al.  Accuracy of Different Putty-Wash Impression Techniques with Various Spacer Thickness , 2012, International journal of clinical pediatric dentistry.

[25]  S. Mishra,et al.  Linear dimensional accuracy of a polyvinyl siloxane of varying viscosities using different impression techniques. , 2010, Journal of investigative and clinical dentistry.

[26]  G. Christensen Ensuring accuracy and predictability with double-arch impressions. , 2008, Journal of the American Dental Association.

[27]  Giuseppe Varvara,et al.  Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel two-step putty/light-body impression technique: an in vitro study. , 2008, The Journal of prosthetic dentistry.

[28]  N. Yamalık Quality systems in dentistry. Part 1. The increasing pressure for quality and implementation of quality assurance and improvement (QA/I) models in health care. , 2007, International dental journal.

[29]  M. Molin,et al.  Longevity and quality of FPDs: a retrospective study of restorations 30, 20, and 10 years after insertion. , 2003, The International journal of prosthodontics.

[30]  J. Nissan,et al.  Effect of wash bulk on the accuracy of polyvinyl siloxane putty-wash impressions. , 2002, Journal of oral rehabilitation.

[31]  T. Brosh,et al.  Accuracy of three polyvinyl siloxane putty-wash impression techniques. , 2000, The Journal of prosthetic dentistry.

[32]  F Houston,et al.  Comparison of the dimensional accuracy of one- and two-step techniques with the use of putty/wash addition silicone impression materials. , 1995, The Journal of prosthetic dentistry.

[33]  D E Tira,et al.  Accuracy of one-step versus two-step putty wash addition silicone impression technique. , 1992, The Journal of prosthetic dentistry.

[34]  P. K. Madineni,et al.  A Comparative Study to Evaluate the Accuracy of Various Spacer Thickness for Polyvinyl Siloxane Putty-wash Impression Techniques: An In Vitro Study , 2020, International journal of clinical pediatric dentistry.

[35]  H. Özdemir,et al.  Evaluation of the effect of storage time and disinfectant solutions on the dimensional accuracy of impression materials with digital radiography. , 2019, Dental and medical problems.

[36]  P. Vallittu,et al.  Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review , 2018, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[37]  J. Nissan,et al.  Effect of various putty-wash impression techniques on marginal fit of cast crowns. , 2013, The International journal of periodontics & restorative dentistry.

[38]  Kishan Singh,et al.  Effect of different impression techniques on the dimensional accuracy of impressions using various elastomeric impression materials: an in vitro study. , 2012, The journal of contemporary dental practice.

[39]  G. H. Johnson,et al.  Clinical trial investigating success rates for polyether and vinyl polysiloxane impressions made with full-arch and dual-arch plastic trays. , 2010, The Journal of prosthetic dentistry.

[40]  Michal Shohat,et al.  A clinical evaluation of fixed partial denture impressions , 2005 .

[41]  C. Fenske The influence of five impression techniques on the dimensional accuracy of master models. , 2000, Brazilian dental journal.