Transient and quasi-steady thermal behaviour of a building envelope due to retrofitted cavity wall and ceiling insulation

Abstract Accurate understanding of the thermal behaviour of building components is essential for predicting heating or cooling needs and facilitates the implementation of more successful energy saving strategies and retrofits. This paper focuses on a specific measure commonly introduced through the residential energy efficiency retrofit programmes in Ireland–insulation. Traditionally, assessments of the performance of building envelopes have been based on assumed thermal resistances of the materials involved, laboratory tests and computer modelling. The aim of the present work is to investigate the in situ thermal behaviour of a case study building and its components under transient and quasi-steady environmental conditions, comparing data before and after the fixing of cavity wall and ceiling insulation. The paper concludes by proposing that predicted values of heat loss using standardised assumed material properties of the existing structure do not reflect the actual values achieved in situ for this test case. These values greatly overestimated the impact of the retrofitted insulation on heat loss through the ceiling and wall.

[1]  S. A. Al-Sanea,et al.  Effect of thermal mass on performance of insulated building walls and the concept of energy savings potential , 2012 .

[2]  N. Lukić The transient house heating condition—the daily changes of the building envelope response factor (BER) , 2005 .

[3]  A. N. Fried,et al.  Thermal properties of a variable cavity wall , 2001 .

[4]  K. Ghazi Wakili,et al.  U-value of a dried wall made of perforated porous clay bricks Hot box measurement versus numerical analysis , 2003 .

[5]  David T. Harrje,et al.  Instrumentation for monitoring energy usage in buildings at Twin Rivers , 1978 .

[6]  B. Boardman,et al.  Making cold homes warmer: the effect of energy efficiency improvements in low-income homes A report to the Energy Action Grants Agency Charitable Trust , 2000 .

[7]  P. T. Tsilingiris The influence of heat capacity and its spatial distribution on the transient wall thermal behavior under the effect of harmonically time-varying driving forces , 2006 .

[8]  Richard Schechner,et al.  On Environmental Design. , 1971 .

[9]  P. T. Tsilingiris Parametric space distribution effects of wall heat capacity and thermal resistance on the dynamic thermal behavior of walls and structures , 2006 .

[10]  Sylvie Lorente,et al.  The effects of temperature conditions on the thermal resistance of walls made with different shapes vertical hollow bricks , 1998 .

[11]  Folke Björk,et al.  Properties of thermal insulation materials during extreme environment changes , 2009 .

[12]  B. R. Anderson The thermal resistance of airspaces in building constructions , 1981 .

[13]  Hugo Hens Energy efficient retrofit of an end of the row house: Confronting predictions with long-term measurements , 2010 .

[14]  Jan Carmeliet,et al.  Brick Cavity Walls: A Performance Analysis Based on Measurements and Simulations , 2007 .

[15]  Mario A. Medina Validation and simulations of a quasi-steady state heat balance model of residential walls , 1999 .

[16]  Paul Baker,et al.  Technical Paper 10: U‐values and traditional buildings - In situ measurements and their comparisons to calculated values , 2011 .

[17]  Jan Kosny,et al.  Influence of insulation configuration on heating and cooling loads in a continuously used building , 2002 .

[18]  Rudolph C. Valore,et al.  Calculations of U-Values of HollowConcrete Masonry , 1980 .

[19]  Paul Baker Technical Paper 2: In situ U-value measurements in traditional buildings – preliminary results , 2008 .

[20]  Brian Anderson,et al.  Uncertainty in the thermal conductivity of insulation materials , 2010 .

[21]  Hans Müller-Steinhagen,et al.  Temperature and Moisture Dependence of the Thermal Conductivity of Insulation Materials , 2005 .

[22]  Frank W. Sinden,et al.  A two-thirds reduction in the space heat requirement of a Twin Rivers townhouse , 1978 .

[23]  Ku-Chin Lin,et al.  The inaccuracy of conventional one-dimensional parallel thermal resistance circuit model for two-dimensional composite walls , 2008 .

[24]  Roberto Ricciu,et al.  Comparing different approaches to in situ measurement of building components thermal resistance , 2011 .

[25]  P. T. Tsilingiris On the thermal time constant of structural walls , 2004 .

[26]  Sung H. Hong,et al.  The impact of energy efficient refurbishment on the space heating fuel consumption in English dwellings , 2006 .