Virtual fractional flow reserve by coronary computed tomography - hope or hype?

Studies evaluating the diagnostic performance of coronary computed tomography angiography (CTA) are consistent in demonstrating a high negative predictive accuracy, but only a modest positive predictive accuracy for the detection of significant coronary artery disease. Consequentially, there has been a considerable effort made to enhance the diagnostic capability of coronary CTA by developing scanner technology and also post-processing algorithms for coronary stenosis evaluation. Of these new developments, the proposition of being able to measure non-invasive fractional flow reserve by coronary computed tomography angiography (FFRct) has generated much recent interest. Initial reports indicate that the application FFRct not only correlates well with invasive fractional flow reserve but also has the potential to enhance substantially the positive predictive accuracy and overall accuracy of coronary CTA. Although it is theoretically possible to measure FFRct using complex computational fluid dynamics adapted from the aeronautical industry, this approach is likely to face a number of challenges prior to it being accepted into the mainstream as an adjunct to coronary CTA. The aim of the current review is to provide an overview of: 1) the fundamental engineering principles behind computational fluid dynamic modelling of coronary arterial blood flow; 2) the difficulties faced from an engineering perspective in developing a truly representative model; and 3) the challenges this technology is likely to face as it attempts to enter the clinical domain.

[1]  C A Taylor,et al.  Outflow boundary conditions for 3D simulations of non-periodic blood flow and pressure fields in deformable arteries , 2010, Computer methods in biomechanics and biomedical engineering.

[2]  N. Paul,et al.  Perioperative β-Blockers : Use With Caution Perioperative β Blockers in Patients Having Non-Cardiac Surgery : A Meta-Analysis , 2010 .

[3]  Steen Z Abildstrom,et al.  64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysis. , 2007, European heart journal.

[4]  Jan Vierendeels,et al.  A simulation environment for validating ultrasonic blood flow and vessel wall imaging based on fluid-structure interaction simulations: ultrasonic assessment of arterial distension and wall shear rate. , 2010, Medical physics.

[5]  Marco Valgimigli,et al.  Diagnostic performance of multislice spiral computed tomography of coronary arteries as compared with conventional invasive coronary angiography: a meta-analysis. , 2006, Journal of the American College of Cardiology.

[6]  Michael J Pencina,et al.  Diagnostic accuracy of fractional flow reserve from anatomic CT angiography. , 2012, JAMA.

[7]  J. Ioannidis,et al.  Meta-analysis of fractional flow reserve versus quantitative coronary angiography and noninvasive imaging for evaluation of myocardial ischemia. , 2007, The American journal of cardiology.

[8]  Guang Lin,et al.  Stochastic Computational Fluid Mechanics , 2007, Computing in Science & Engineering.

[9]  Laurent D. Cohen,et al.  Tubular Structure Segmentation Based on Minimal Path Method and Anisotropic Enhancement , 2011, International Journal of Computer Vision.

[10]  G W Hamilton,et al.  Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve. , 1974, The American journal of cardiology.

[11]  William E. Lorensen,et al.  Marching cubes: A high resolution 3D surface construction algorithm , 1987, SIGGRAPH.

[12]  Maria Siebes,et al.  Physiological assessment of coronary artery disease in the cardiac catheterization laboratory: a scientific statement from the American Heart Association Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology. , 2006, Circulation.

[13]  Yin Wang,et al.  3-D Quantitative Vascular Shape Analysis for Arterial Bifurcations via Dynamic Tube Fitting , 2012, IEEE Transactions on Biomedical Engineering.

[14]  A. Dunning,et al.  Diagnosis of ischemia-causing coronary stenoses by noninvasive fractional flow reserve computed from coronary computed tomographic angiograms. Results from the prospective multicenter DISCOVER-FLOW (Diagnosis of Ischemia-Causing Stenoses Obtained Via Noninvasive Fractional Flow Reserve) study. , 2011, Journal of the American College of Cardiology.

[15]  M E Phelps,et al.  Relation among stenosis severity, myocardial blood flow, and flow reserve in patients with coronary artery disease. , 1995, Circulation.

[16]  Uwe Siebert,et al.  Economic Evaluation of Fractional Flow Reserve–Guided Percutaneous Coronary Intervention in Patients With Multivessel Disease , 2010, Circulation.

[17]  T van Walsum,et al.  Coronary centerline extraction from CT coronary angiography images using a minimum cost path approach. , 2009, Medical physics.

[18]  Jon Harald Kaspersen,et al.  A new method for analysis of motion of carotid plaques from RF ultrasound images. , 2003, Ultrasound in medicine & biology.

[19]  Wiro J. Niessen,et al.  Selective Deblurring for Improved Calcification Visualization and Quantification in Carotid CT Angiography: Validation Using Micro-CT , 2009, IEEE Transactions on Medical Imaging.

[20]  A. Seifalian,et al.  Arterial elastic properties and cardiovascular risk/event. , 2002, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[21]  W. Wijns,et al.  Simultaneous coronary pressure and flow velocity measurements in humans. Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve. , 1996, Circulation.

[22]  Theo van Walsum,et al.  Bayesian Tracking of Elongated Structures in 3D Images , 2007, IPMI.

[23]  D. Saloner,et al.  Numerical analysis of flow through a severely stenotic carotid artery bifurcation. , 2002, Journal of biomechanical engineering.

[24]  Avner Friedman,et al.  Blood Flow in a Compliant Vessel by the Immersed Boundary Method , 2009, Annals of Biomedical Engineering.

[25]  G. Hillis,et al.  64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis , 2008, Heart.

[26]  G. Karniadakis,et al.  Modeling Blood Flow Circulation in Intracranial Arterial Networks: A Comparative 3D/1D Simulation Study , 2010, Annals of Biomedical Engineering.

[27]  Panos Liatsis,et al.  Automatic Segmentation of Coronary Arteries in CT Imaging in the Presence of Kissing Vessel Artifacts , 2012, IEEE Transactions on Information Technology in Biomedicine.

[28]  G. Pelosi The finite-element method, Part I: R. L. Courant [Historical Corner] , 2007, IEEE Antennas & Propagation Magazine.

[29]  U. Siebert,et al.  Fractional flow reserve versus angiography for guiding percutaneous coronary intervention. , 2009, The New England journal of medicine.

[30]  P. H. van der Voort,et al.  Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenoses. , 1996, The New England journal of medicine.

[31]  K. Lipscomb,et al.  Instantaneous Flow Response and Regional Distribution During Coronary Hyperemia as Measures of Coronary Flow Reserve , 1974 .

[32]  Rainald Löhner,et al.  Large-scale fluid-structure interaction simulations , 2004 .

[33]  M. Budoff,et al.  Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Indi , 2008, Journal of the American College of Cardiology.

[34]  Toshio Kobayashi,et al.  Finite element simulation of blood flow in the cerebral artery , 2001 .

[35]  Anamika Prasad,et al.  Computational Analysis of Stresses Acting on Intermodular Junctions in Thoracic Aortic Endografts , 2011, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[36]  Mathias Prokop,et al.  Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study. , 2008, Journal of the American College of Cardiology.

[37]  J. Min,et al.  ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 Appropriate Use Criteria for Cardiac Computed Tomography. A Report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the Society of Cardiovascular Computed Tomography, the American College of Radiology, the American , 2010, Journal of cardiovascular computed tomography.

[38]  William Wijns,et al.  Percutaneous coronary intervention of functionally nonsignificant stenosis: 5-year follow-up of the DEFER Study. , 2007, Journal of the American College of Cardiology.

[39]  Charles A. Taylor,et al.  In Vitro Validation of Finite Element Analysis of Blood Flow in Deformable Models , 2011, Annals of Biomedical Engineering.

[40]  Endre Süli,et al.  Finite Volume Methods and their Analysis , 1991 .