The Research of Secondary Arc Spectrum Characteristics on UHV

On UHV power transmission lines, when single-phase ground fault happen, it will appear secondary arc on lines, the existence of secondary arc impact on the stable operation of system. The effectiveness of single-pole autoreclosure (SPAR) in maintaining power system stability is largely determined by the speed with which secondary arc extinction, and hence autoreclosure, can be achieved. The paper adopts total harmonic distortion (THD) to judge the status of arc. First, the simulation model of secondary arc is established by ATP software. Then, faulted phase voltage and secondary arc are simulated in different close angle. Last, spectrum characteristics and harmonic content of faulted phase voltage and current are analyzed in different close angle, at the same time, THD of non-faulted phase is also analyzed by Fourier algorithm. Through the fault phase voltage and current simulation and Fourier analysis, which comes to the conclusion that at the peak in the power supply voltage secondary arc is the most difficult to extinguish and the harm to insulation is the greatest. DOI:  http://dx.doi.org/10.11591/telkomnika.v10i6.1411 Full Text: PDF

[1]  P. Schegner,et al.  Impacts of operating conditions and line parameters on secondary arc extinction of single-phase autoreclosures , 2005, 2005 International Conference on Future Power Systems.

[2]  Reni Suryanita,et al.  Intelligent Monitoring System on Prediction of Building Damage Index using Neural-Network , 2012 .

[3]  Z. M. Radojevic Numerical Algorithm for Adaptive Single Pole Autoreclosure Based on Determining the Secondary Arc Extinction Time , 2006 .

[4]  Xu Jianyuan,et al.  The Analysis of Secondary Arc Extinction Characteristics on UHV Transmission Lines , 2008, 2008 International Conference on High Voltage Engineering and Application.

[5]  M. E. Hamedani Golshan,et al.  Detecting secondary arc extinction time by analyzing low frequency components of faulted phase voltage or sound phase current waveforms , 2006 .

[6]  A. T. Johns,et al.  Design and implementation of an adapative single pole autoreclosure technique for transmission lines using artificial neural networks , 1996 .

[7]  Ismail Daut,et al.  Relationships between Harmonic Characteristics and Different Types of Voltage Source , 2012 .

[8]  M. Kristiansen,et al.  Analysis of Distributed Energy Railguns to Suppress Secondary Arc Formation , 2008, 2008 14th Symposium on Electromagnetic Launch Technology.

[9]  M.V. Dmitriev,et al.  EMTP simulation of the secondary arc extinction at overhead transmission lines under single phase automatic reclosing , 2005, 2005 IEEE Russia Power Tech.