Coherence-gated Doppler: a fiber sensor for precise localization of blood flow

Miniature optical sensors that can detect blood vessels in front of advancing instruments will significantly benefit many interventional procedures. Towards this end, we developed a thin and flexible coherence-gated Doppler (CGD) fiber probe (O.D. = 0.125 mm) that can be integrated with minimally-invasive tools to provide real-time audio feedback of blood flow at precise locations in front of the probe. Coherence-gated Doppler (CGD) is a hybrid technology with features of laser Doppler flowmetry (LDF) and Doppler optical coherence tomography (DOCT). Because of its confocal optical design and coherence-gating capabilities, CGD provides higher spatial resolution than LDF. And compared to DOCT imaging systems, CGD is simpler and less costly to produce. In vivo studies of rat femoral vessels using CGD demonstrate its ability to distinguish between artery, vein and bulk movement of the surrounding soft tissue. Finally, by placing the CGD probe inside a 30-gauge needle and advancing it into the brain of an anesthetized sheep, we demonstrate that it is capable of detecting vessels in front of advancing probes during simulated stereotactic neurosurgical procedures. Using simultaneous ultrasound (US) monitoring from the surface of the brain we show that CGD can detect at-risk blood vessels up to 3 mm in front of the advancing probe. The improved spatial resolution afforded by coherence gating combined with the simplicity, minute size and robustness of the CGD probe suggest it may benefit many minimally invasive procedures and enable it to be embedded into a variety of surgical instruments.

[1]  Johan Richter,et al.  Intracerebral Microvascular Measurements during Deep Brain Stimulation Implantation using Laser Doppler Perfusion Monitoring , 2007, Stereotactic and Functional Neurosurgery.

[2]  H. Eun,et al.  Evaluation of skin blood flow by laser Doppler flowmetry. , 1995, Clinics in dermatology.

[3]  V. Rajan,et al.  Review of methodological developments in laser Doppler flowmetry , 2009, Lasers in Medical Science.

[4]  Eric De Groot,et al.  Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients , 2006, Critical care.

[5]  B. Matthews,et al.  Pulpal blood flow recorded from human premolar teeth with a laser Doppler flow meter using either red or infrared light. , 2011, Archives of oral biology.

[6]  Ron D. Frostig,et al.  Optical Doppler tomography , 1999 .

[7]  T. V. van Leeuwen,et al.  In vivo optical path lengths and path length resolved doppler shifts of multiply scattered light , 2010, Lasers in surgery and medicine.

[8]  Stefan K. Piechnik,et al.  Modelling vascular reactivity to investigate the basis of the relationship between cerebral blood volume and flow under CO2 manipulation , 2008, NeuroImage.

[9]  Victor X D Yang,et al.  Wide dynamic range detection of bidirectional flow in Doppler optical coherence tomography using a two-dimensional Kasai estimator. , 2007, Optics letters.

[10]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[11]  J. Gardin,et al.  Evaluation of blood flow velocity in the ascending aorta and main pulmonary artery of normal subjects by Doppler echocardiography. , 1984, American heart journal.

[12]  Siavash Yazdanfar,et al.  Real-time, high velocity-resolution color Doppler optical coherence tomography. , 2002, Optics letters.

[13]  M. V. van Gemert,et al.  Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography. , 1997, Optics letters.

[14]  Thomas E. Milner,et al.  Optical Doppler Tomography , 1999, Definitions.

[15]  W Steenbergen,et al.  Path-length distribution and path-length-resolved Doppler measurements of multiply scattered photons by use of low-coherence interferometry. , 2001, Optics letters.

[16]  Julius Pekar,et al.  High speed, wide velocity dynamic range Doppler optical coherence tomography (Part I): System design, signal processing, and performance. , 2003, Optics express.

[17]  Thomas Grau,et al.  Efficacy of ultrasound imaging in obstetric epidural anesthesia. , 2002, Journal of clinical anesthesia.