Phase-contrast scanning transmission electron microscopy.

This report introduces the first results obtained using phase-contrast scanning transmission electron microscopy (P-STEM). A carbon-film phase plate (PP) with a small center hole is placed in the condenser aperture plane so that a phase shift is introduced in the incident electron waves except those passing through the center hole. A cosine-type phase-contrast transfer function emerges when the phase-shifted scattered waves interfere with the non-phase-shifted unscattered waves, which passed through the center hole before incidence onto the specimen. The phase contrast resulting in P-STEM is optically identical to that in phase-contrast transmission electron microscopy that is used to provide high contrast for weak phase objects. Therefore, the use of PPs can enhance the phase contrast of the STEM images of specimens in principle. The phase shift resulting from the PP, whose thickness corresponds to a phase shift of π, has been confirmed using interference fringes displayed in the Ronchigram of a silicon single crystal specimen. The interference fringes were found to abruptly shift at the edge of the PP hole by π.

[1]  K. Nagayama,et al.  Direct observation of biological molecules in liquid by environmental phase-plate transmission electron microscopy. , 2012, Micron.

[2]  R. Schröder,et al.  Optimizing phase contrast in transmission electron microscopy with an electrostatic (Boersch) phase plate. , 2007, Ultramicroscopy.

[3]  K. Nagayama,et al.  Complex Observation in Electron Microscopy. II. Direct Visualization of Phases and Amplitudes of Exit Wave Functions , 2001 .

[4]  K. Nagayama,et al.  Transfer doublet and an elaborated phase plate holder for 120 kV electron-phase microscope. , 2005, Journal of electron microscopy.

[5]  James E. Evans,et al.  Visualizing macromolecular complexes with in situ liquid scanning transmission electron microscopy. , 2012, Micron.

[6]  A. Tonomura,et al.  The phase constancy of electron waves traveling through Boersch's electrostatic phase plate , 1996 .

[7]  H. Minoda,et al.  Contrast enhancement in the phase plate transmission electron microscopy using an objective lens with a long focal length. , 2011, Journal of Electron Microscopy.

[8]  K. Nagayama,et al.  A Novel Phase-contrast Transmission Electron Microscopy Producing High-contrast Topographic Images of Weak objects , 2002, Journal of biological physics.

[9]  K. Downing,et al.  Design of a microfabricated, two-electrode phase-contrast element suitable for electron microscopy. , 2006, Ultramicroscopy.

[10]  Robert M Glaeser,et al.  Practical factors affecting the performance of a thin-film phase plate for transmission electron microscopy. , 2009, Ultramicroscopy.

[11]  Kazuhiro Aoyama,et al.  STEM tomography for thick biological specimens. , 2008, Ultramicroscopy.

[12]  F. Tseng,et al.  The fabrication and application of Zernike electrostatic phase plate. , 2007, Journal of electron microscopy.

[13]  R. Glaeser,et al.  Design of a hybrid double-sideband/single-sideband (schlieren) objective aperture suitable for electron microscopy. , 2011, Ultramicroscopy.