Electromagnetic Biosensing of Respiratory Rate

Continuous monitoring of respiratory rate is crucial in forecasting health crises and other major physiological instabilities. Current respiratory monitoring methods limit the mobility of the patient or require constant battery replacement. Wireless, wearable technology can collect continuous physiological data without immobilizing or inconveniencing patients, and human energy harvesting can be used to power these wearable sensors. In this paper, we explore this zero-net energy biosensor concept through simultaneous sensing and harvesting of respiratory effort. An off-the-shelf dc brushed motor is modified into a chest belt, and tested on a mechanical chest simulator as well as on 20 human subjects, using a spirometer as a reference. The electromagnetic biosensor is used to successfully harvest 7-70 μW from human subjects. On the mechanical chest, respiratory rate is detected with a mean absolute error of 0.00027 breaths/min with a standard deviation of 0.00019 breaths/min. For human subjects, respiratory rate is detected with a mean difference of 0.36 breaths/min with a standard deviation of 2.83 breaths/min (sitting), 0.23 breaths/min with a standard deviation of 2.64 breaths/min (standing), and 0.48 breaths/min with a standard deviation of 3.06 breaths/min (walking).

[1]  D. Goldhill,et al.  Physiological values and procedures in the 24 h before ICU admission from the ward , 1999, Anaesthesia.

[2]  S. J. Redmond,et al.  Sensors-Based Wearable Systems for Monitoring of Human Movement and Falls , 2012, IEEE Sensors Journal.

[3]  D. Wakefield,et al.  Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatients , 1993, Journal of General Internal Medicine.

[4]  M R Neuman Vital Signs [Tutorial] , 2011, IEEE Pulse.

[5]  Ab Stevels,et al.  Human power, a sustainable option for electronics , 1999, Proceedings of the 1999 IEEE International Symposium on Electronics and the Environment (Cat. No.99CH36357).

[6]  Olga Boric-Lubecke,et al.  Respiratory rate detection using a wearable electromagnetic generator , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  Olga Boric-Lubecke,et al.  Electromagnetic generator: As respiratory effort energy harvester , 2011, 2011 IEEE Power and Energy Conference at Illinois.

[8]  Paolo Bonato,et al.  Wearable Sensors and Systems , 2010, IEEE Engineering in Medicine and Biology Magazine.

[9]  M. S. Lu,et al.  A CMOS MEMS Capacitive Flow Sensor for Respiratory Monitoring , 2013, IEEE Sensors Journal.

[10]  P. Dupuis,et al.  Dew-Based Wireless Mini Module for Respiratory Rate Monitoring , 2012, IEEE Sensors Journal.

[11]  Olga Boric-Lubecke,et al.  Measuring chest circumference change during respiration with an electromagnetic biosensor , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[12]  Chia-Ling Wei,et al.  A Novel MEMS Respiratory Flow Sensor , 2010, IEEE Sensors Journal.

[13]  Taeseung D. Yoo,et al.  Generating Electricity While Walking with Loads , 2022 .

[14]  Joseph A. Paradiso,et al.  Parasitic power harvesting in shoes , 1998, Digest of Papers. Second International Symposium on Wearable Computers (Cat. No.98EX215).

[15]  Olga Boric-Lubecke,et al.  Zero-Net Energy Wearable Biosensors , 2010, CATA.

[16]  Se Dong Min,et al.  Noncontact Respiration Rate Measurement System Using an Ultrasonic Proximity Sensor , 2010, IEEE Sensors Journal.

[17]  O. Boric-Lubecke,et al.  Non-contact respiratory rate measurement validation for hospitalized patients , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.