2-D motion estimation using two parallel receive beams

We describe a method for estimating 2-D target motion using ultrasound. The method is based on previous ensemble tracking techniques, which required at least four parallel receive beams and 2-D pattern matching. In contrast, the method described requires only two parallel receive beams and 1-D pattern matching. Two 1-D searches are performed, one in each lateral direction. The direction yielding the best match indicates the lateral direction of motion. Interpolation provides sub-pixel magnitude resolution. We compared the two beam method with the four beam method using a translating speckle target at three different parallel beam steering angles and transducer angles of 0, 45, and 90/spl deg/. The largest differences were found at 90 degrees, where the two beam method was generally more accurate and precise than the four beam method and also less prone to directional errors at small translations. We also examined the performance of both methods in a laminar flow phantom. Results indicated that the two beam method was more accurate in measuring the flow angle when the flow velocity was small. Computer simulations supported the experimental findings. The poorer performance of the four beam method was attributed to differences in correlation among the parallel beams. Specifically, center beams 2 and 3 correlated better with each other than with the outer beams. Because the four beam method used a comparison of a kernel region in beam pair 2-3 with two different beam pairs 1-2 and 3-4, the 2-to-1 and 3-to-4 components of this comparison increased the incidence of directional errors, especially at small translations. The two beam method used a comparison between only two beams and so was not subject to this source of error. Finally, the two beam method did not require amplitude normalization, as was necessary for the four beam method, when the two beams were chosen symmetric to the transmit axis. We conclude that two beam ensemble tracking can accurately estimate motion using only two parallel receive beams.

[1]  R. F. Wagner,et al.  Fundamental correlation lengths of coherent speckle in medical ultrasonic images , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  P. Picot,et al.  Quantitative volume flow estimation using velocity profiles , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  O. Bonnefous Measurement of the complete (3D) velocity vector of blood flows , 1988, IEEE 1988 Ultrasonics Symposium Proceedings..

[4]  B. J. Geiman,et al.  Ensemble tracking for 2D vector velocity measurement: Experimental and initial clinical results , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  M.E. Aderson,et al.  Multi-dimensional velocity estimation with ultrasound using spatial quadrature , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  G. Trahey,et al.  Angle Independent Ultrasonic Detection of Blood Flow , 1987, IEEE Transactions on Biomedical Engineering.

[8]  W. O’Brien,et al.  A comparison of the motion tracking of 2-D ultrasonic B-mode tissue images with a calibrated phantom , 1991, IEEE 1991 Ultrasonics Symposium,.

[9]  B. J. Geiman,et al.  A novel interpolation strategy for estimating subsample speckle motion. , 2000, Physics in medicine and biology.

[10]  Marc D Weinshenker,et al.  Explososcan: a parallel processing technique for high speed ultrasound imaging with linear phased arrays. , 1984 .

[11]  B. Friemel,et al.  Experimental velocity profiles and volumetric flow via two-dimensional speckle tracking. , 1995, Ultrasound in medicine & biology.

[12]  J. Ophir,et al.  A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strains and Poisson's ratios in tissues. , 1998, Ultrasound in medicine & biology.

[13]  L.N. Bohs,et al.  A novel method for angle independent ultrasonic imaging of blood flow and tissue motion , 1991, IEEE Transactions on Biomedical Engineering.

[14]  R. Gill Measurement of blood flow by ultrasound: accuracy and sources of error. , 1985, Ultrasound in medicine & biology.

[15]  J. Jensen,et al.  A new method for estimation of velocity vectors , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  M. Fox Multiple crossed-beam ultrasound Doppler velocimetry , 1978 .

[17]  W.D. O'Brien,et al.  Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-a review , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  G. Trahey,et al.  Potential and Limitations of Angle-Independent Flow Detection Algorithms Using Radio-Frequency and Detected Echo Signals , 1991 .

[19]  V. Newhouse,et al.  Ultrasound Doppler Probing of Flows Transverse with Respect to Beam Axis , 1987, IEEE Transactions on Biomedical Engineering.

[20]  I. Hein 3-D flow velocity vector estimation with a triple-beam lens transducer-experimental results , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.