A study on the identification and quantification of sources of VOCs in 5 air-conditioned Singapore office buildings

Sources of VOCs were identi%ed and quanti%ed in %ve tropical air-conditioned o.ce buildings in Singapore. A mass balanced model is applied to determine area-speci%c emission rates and to apportion the sources of VOCs into 3 broad categories of sources—building materials, ventilation systems and occupants and their activities. The highest contributor of TVOCs comes from the ventilation systems at 39.0%. This was followed by occupants and their activities at 37.3% and %nally building materials at 23.7%. Ducted supply and return ventilation design has the lowest VOC area-speci%c emission rates as compared to buildings employing the open space above the false ceiling as return plenum. The TVOC area-speci%c emission rates from building materials and ventilation systems decreased from 6 to 12 months. However, some VOCs showed increased emission rates over the same period demonstrating sink e

[1]  P Wolkoff,et al.  Trends in Europe to reduce the indoor air pollution of VOCs. , 2003, Indoor air.

[2]  M. Mason,et al.  Organic emissions from consumer products and building materials to the indoor environment. , 1988, JAPCA.

[3]  Per Axel Clausen,et al.  The Danish Twin Apartment Study – Part II: Mathematical modeling of the relative strength of sources of indoor air pollution , 1996 .

[4]  P. Lagus,et al.  A review of tracer-gas techniques for measuring airflows in buildings , 1985 .

[5]  Richard A. Grot,et al.  Sources and Source Strengths of Volatile Organic Compounds in a New Office Building , 1991 .

[6]  Geo Clausen,et al.  Total Volatile Organic Compounds (TVOC) in Indoor Air Quality Investigations , 1997 .

[7]  A T Hodgson,et al.  Volatile organic compound concentrations and emission rates in new manufactured and site-built houses. , 2000, Indoor air.

[8]  Tunga Salthammer,et al.  Emission of Volatile Organic Compounds from Furniture Coatings , 1997 .

[9]  Derrick Crump,et al.  A review of the emission of VOCs from polymeric materials used in buildings , 1998 .

[10]  Tunga Salthammer,et al.  Interaction of volatile organic compounds with indoor materials—a small-scale screening method , 1999 .

[11]  S. C. Sekhar,et al.  A critical evaluation of variable air volume system in hot and humid climates , 1997 .

[12]  Povl Ole Fanger,et al.  European audit project to optimise indoor air quality and energy consumption in office buildings , 1994 .

[13]  K W Tham,et al.  Emission modelling and validation of VOCs' source strengths in air-conditioned office premises. , 2004, Environment international.

[14]  G. Clausen,et al.  Why, when and how do HVAC - systems pollute the indoor environment and what to do about it ? The European AIRLESS project , 2003 .

[15]  Pertti Pasanen,et al.  Hygienic Aspects of Processing Oil Residues in Ventilation Ducts , 1995 .

[16]  S. K. Brown,et al.  Volatile organic pollutants in new and established buildings in Melbourne, Australia. , 2002, Indoor air.

[17]  Lance Wallace,et al.  Emissions of volatile organic compounds from building materials and consumer products , 1987 .

[18]  Povl Ole Fanger,et al.  Air Pollution Sources in Offices and Assembly Halls, Quantified by the olf Unit , 1988 .

[19]  X Yang,et al.  A coupled airflow and source/sink model for simulating indoor VOC exposures. , 2001, Indoor air.

[20]  S. K. Brown,et al.  Assessment of pollutant emissions from dry-process photocopiers. , 1999, Indoor air.