Seismic proof test of a reinforced concrete containment vessel (RCCV): Part 2: Results of shaking table tests

Abstract A 1/8-scale model was constructed of a reinforced concrete containment vessel (RCCV) used in the latest advanced boiling water reactors (ABWR). Shaking table tests were conducted on it with input motions corresponding to or exceeding a design earthquake assumed for a real Nuclear Power Plant. The objectives of the tests were to verify the structural integrity and the leak-proof functional soundness of the RCCV subjected to design earthquakes, and to determine the ultimate strength and seismic margin by an excitation that led to the model's collapse. The model, the test sequence and the pressure and leak test results were addressed in Part 1. The shaking table test method, the input motions and the test results, including the transition of the model's stiffness, natural frequencies and damping factors and the effects of vertical input motions and internal pressure on the model's characteristics and behavior, the load–deformation, the ultimate strength, the failure mode of the reinforced concrete portion and the liner plate are described here. The seismic safety margin that was evaluated by the energy input during the failure test to a design basis earthquake will be described in Part 3. The analytical results of simulation using the multi-lumped mass model will be described in Part 4.

[1]  Shizuo Tsurumaki,et al.  Experimental Study on RCCV of ABWR Plant - Part 7: Horizontal Force Test of Total Model (1/6th Scale) , 1989 .

[2]  G. W. Housner,et al.  Behavior of Structures During Earthquakes , 1959 .

[3]  Yasuo Inada RESTORING FORCE CHARACTERISTICS OF REACTOR BUILDINGS BASED ON LOAD TESTS AND NUMERICAL ANALYSIS : (Part 3) Examination of load displacement hysteresis loops , 1987 .

[4]  Hiroshi Akiyama,et al.  Earthquake-resistant limit-state design for buildings , 1985 .

[5]  S. Timoshenko Theory of Elastic Stability , 1936 .

[6]  Hiroshi Akiyama,et al.  FUNDAMENTAL PROPERTIES OF FIRST STORY ENERGY CONCENTRATED STEEL STRUCTURE WITH FLEXIBLE-STIFF MIXED FRAMES , 1989 .

[7]  Hiroshi Akiyama,et al.  Seismic proof test of a reinforced concrete containment vessel (RCCV): Part 1: Test model and pressure test , 2005 .

[8]  Norio Inoue,et al.  A STUDY ON ENERGY RESPONSE OF RC STRUCTURES AGAINST EARTHQUAKES AND DETERMINATION OF RESISTANCE LEVEL CONSIDERING RESPONSE LIMITS , 1996 .

[9]  衣笠 秀行,et al.  RC構造物のエネルギーに基づく設計法開発のための基礎的研究 : その1 エネルギー入力速度EIVを考慮した性能評価型設計法 , 1996 .

[10]  D. Mitchell,et al.  Prestressed concrete structures , 1991 .

[11]  Takehiko Terada,et al.  PSEUDO-DYNAMIC TEST ON FULL-SCALE MODEL OF FIRST-STORY ENERGY-CONCENTRATED STEEL STRUCTURE WITH FLEXIBLE-STIFF MIXED FRAME , 1990 .

[12]  H Sato,et al.  Large Scale Aseismic Proving Test of BMR Reactor Pressure Vessel by Tadotsu Table , 1991 .

[13]  Takehiko Terada,et al.  ELASTO-PLASTIC SHAKING TABLE TEST OF FIRST-STORY ENRGY-CONCENTRATED TYPE MULTI-STORY STEEL FRAME WITH FLEXIBLE-STIFF MIXED STRUCTURES , 1990 .

[14]  Toshio Nagashima,et al.  DYNAMIC RESTORING FORCE CHARACTERISTICS OF REINFORCED CONCRETE SHEAR WALL IN REACTOR BUILDING : Energy dissipation capacity on plastic state and hysteresis model for dynamic analysis , 1997 .