Robust capacitor-current-feedback active damping for the LCL-type grid-connected inverter

This paper explores the effect of the computation and pulsewidth modulation (PWM) delays on the capacitor-current-feedback active damping for the LCL-type grid-connected inverter. It turns out that proportional feedback of the capacitor current is equivalent to a virtual impedance connected in parallel with the filter capacitor in digital control. The LCL-filter resonance frequency is changed by this virtual impedance. And if the actual resonance frequency is higher than one-sixth of the sampling frequency (fs/6), where the virtual impedance contains a negative resistor component, a pair of open-loop unstable poles will be generated. As a result, the LCL-type grid-connected inverter becomes much easier to be unstable if the resonance frequency is moved closer to fs/6 due to the variation of the grid impedance. To address this issue, this paper proposes a capacitor-current-feedback active damping with reduced computation delay, which is achieved by shifting the capacitor current sampling instant towards the PWM reference update instant. With this method, the virtual impedance exhibits more like a resistor in a wider frequency range, and the open-loop unstable poles are removed, thus high robustness against the grid-impedance variation is acquired. Experimental results confirm the theoretical expectations.

[1]  Xinbo Ruan,et al.  Design of injected grid current regulator and capacitor-current-feedback active-damping for LCL-type grid-connected inverter , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[2]  J L Agorreta,et al.  Modeling and Control of $N$ -Paralleled Grid-Connected Inverters With LCL Filter Coupled Due to Grid Impedance in PV Plants , 2011, IEEE Transactions on Power Electronics.

[3]  Xinbo Ruan,et al.  Magnetic integration of an LCL filter for the single-phase grid-connected inverter , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[4]  M. Liserre,et al.  A new control structure for grid-connected LCL PV inverters with zero steady-state error and selective harmonic compensation , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[5]  M. Liserre,et al.  Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values , 2006, IEEE Transactions on Power Electronics.

[6]  Steffen Bernet,et al.  Design of $LCL$ Filters of Active-Front-End Two-Level Voltage-Source Converters , 2009, IEEE Transactions on Industrial Electronics.

[7]  Xinbo Ruan,et al.  Design of the PI regulator and feedback coefficient of capacitor current for grid-connected inverter with an LCL filter in discrete-time domain , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[8]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady state error , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[9]  Xinbo Ruan,et al.  Full-Feedforward Schemes of Grid Voltages for a Three-Phase $LCL$-Type Grid-Connected Inverter , 2013, IEEE Transactions on Industrial Electronics.

[10]  Donald Grahame Holmes,et al.  Regions of active damping control for LCL filters , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[11]  Frede Blaabjerg,et al.  Generalized Design of High Performance Shunt Active Power Filter With Output LCL Filter , 2012, IEEE Transactions on Industrial Electronics.

[12]  D. G. Holmes,et al.  Optimized Design of Stationary Frame Three Phase AC Current Regulators , 2009, IEEE Transactions on Power Electronics.

[13]  H. Pinheiro,et al.  Design and Implementation of a Robust Current Controller for VSI Connected to the Grid Through an LCL Filter , 2009, IEEE Transactions on Power Electronics.

[14]  D. G. Holmes,et al.  High performance current regulation for low pulse ratio inverters , 2011 .

[15]  Marco Liserre,et al.  Filter-Based Active Damping of Voltage Source Converters With $LCL$ Filter , 2011, IEEE Transactions on Industrial Electronics.

[16]  Yun Wei Li,et al.  Generalized Closed-Loop Control Schemes with Embedded Virtual Impedances for Voltage Source Converters with LC or LCL Filters , 2012, IEEE Transactions on Power Electronics.

[17]  Yun Wei Li,et al.  Control and Resonance Damping of Voltage-Source and Current-Source Converters With $LC$ Filters , 2009, IEEE Transactions on Industrial Electronics.

[18]  Paolo Mattavelli,et al.  Digital Control in Power Electronics , 2006, Digital Control in Power Electronics.