The desirability of mechanical ventilation in homes and acceptable infiltration rates are sometimes contentious topics – particularly in humid climates. We present preliminary results of two monitored lab homes constructed to represent the thermal characteristics of typical existing Florida homes. They are configured for the ventilation study with tight and leaky envelopes and with and without mechanical ventilation. We also present simulation results of high performance new homes with mechanical ventilation and typical older existing homes with and without air tightening and mechanical ventilation to provide added context. Lab home test results indicate that mechanical supply ventilation of the tight home (2 ach50) in accordance with ASHRAE 62.2-3013 increased average indoor relative humidity by 2.2% as compared with the leaky home (8 ach50) without mechanical ventilation in the hot, humid climate of central Florida. However, cooling energy use was increased by about 27% due to substantially increased air conditioner moisture removal (>63%). Results also indicate that failure to ventilate the tight home during winter results in excessive indoor relative humidity due to typical internal moisture gains. To explore other conditions and climates, highly-efficient new tight homes (1.5 and 3 ach50) were simulated in twelve TMY3 weather files representing five U.S. climate zones. Existing leaky homes (11 ach50) were also simulated for one TMY city. Parametric analysis was accomplished using different ventilation system types with and without dehumidification. Background
[1]
D. Hoak,et al.
Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Heating Season Energy and Moisture Levels
,
2013
.
[2]
Dane Christensen,et al.
Moisture Modeling : Effective Moisture Penetration Depth Versus Effective Capacitance
,
1995
.
[3]
Jon Winkler,et al.
Evaluation of the Effective Moisture Penetration Depth Model for Estimating Moisture Buffering in Buildings
,
2013
.
[4]
Philip Fairey,et al.
Updated Miscellaneous Electricity Loads and Appliance Energy Usage Profiles for Use in Home Energy Ratings, the Building America Benchmark Procedures and Related Calculations. Revised
,
2011
.
[5]
Max H. Sherman,et al.
Humidity Implications for Meeting Residential Ventilation Requirements
,
1995
.
[6]
Joseph Lstiburek,et al.
Systems Research on Residential Ventilation
,
2008
.
[7]
Vice President,et al.
AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS INC.
,
2007
.
[8]
K. McIlvaine,et al.
Energy Retrofit Field Study and Best Practices in a Hot-Humid Climate
,
2013
.