The pressure within a collapsed tube, with special reference to urethral pressure.

A definition is proposed for tube pressure (the pressure within a collapsible tube in the collapsed state, e.g. the urethral pressure or the pressure in the anal or oesophageal sphincter) which conforms to the common sense view that it is a measure of the ability of the tube to prevent leakage. It is not dependent on the orientation of a measuring probe in the tube. The orientation effects which have previously been reported are due to attempted bending of a stiff measuring catheter by internally and externally applied forces. A satisfactory way of measuring the tube pressure, by slow perfusion through a thin, flexible catheter with an end hole, and of testing whether it is a meaningful concept in a given case, is proposed. It is illustrated by measurements of urethral pressure in 42 continent and incontinent females. No cases of urinary incontinence due to poor urethral sealing ability are observed, indicating that tube pressure is a meaningful concept. The theory of viscosity-limited flow through a compressive zone in a collapsible tube, on which the perfusion method of measuring tube pressure is based, is developed.

[1]  R. Ritter,et al.  Role of inner urethral softness in urinary continence. , 1980, Urology.

[2]  J. Heidenreich,et al.  Simultane Druckmessung in Harnblase und Harnröhre zur Diagnostik der Harninkontinenz , 2004, Archiv für Gynäkologie.

[3]  A. Shapiro Steady Flow in Collapsible Tubes , 1977 .

[4]  D. J. Griffiths,et al.  Urodynamics: The Mechanics and Hydrodynamics of the Lower Urinary Tract , 1980 .

[5]  R. Beart,et al.  Longitudinal and radial variations of pressure in the human anal sphincter. , 1984, Gastroenterology.

[6]  J. Susset,et al.  Urethral pressure profile. Standardization of technique and study of reproducibility. , 1975, Urology.

[7]  W E Bradley,et al.  The standardization of terminology of lower urinary tract function. , 1979, The Journal of urology.

[8]  P. Abrams,et al.  The measurement and interpretation of urethral pressures obtained by the method of Brown and Wickham. , 1978, British journal of urology.

[9]  M. Kaye,et al.  Manometric configuration of the lower esophageal sphincter in normal human subjects. , 1971, Gastroenterology.

[10]  S. Plevnik Model of the proximal urethra: measurement of the urethral stress profile. , 1976, Urologia internationalis.

[11]  T. Hennessy,et al.  Oesophageal manometry. A comparison of hydraulic and syringe catheter infusion systems using a simple hydrostatic bench model. , 1984, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.