Active islanding detection using high frequency signal injection

Islanding detection is of great importance for reliable operation of smart grids. Islanding detection methods can be classified into three different groups: active, passive and communication based methods. Active methods inject a disturbing signal (typically a voltage) and analyze the system response (typically in the current). These techniques have a low non-detection zone but present the inconvenience inherent to injecting a disturbing signal. Passive methods monitor the grid condition from the grid variables. These techniques are easy to implement, but present a large non-detection zone. Communications methods have the inconvenient of relying on communications, currently being of limited use. This paper proposes a new active islanding detection method, based on measurement of the grid high frequency impedance by means of the injection of a high frequency voltage. Advantages of the method are almost negligible adverse effects due to the injected high frequency voltage and accurate and fast islanding detection -in the rage of few ms-. Furthermore, the estimated high frequency impedance can be used for adaptive control of the power converter.1

[1]  Timothy C. Green,et al.  High-Quality Power Generation Through Distributed Control of a Power Park Microgrid , 2006, IEEE Transactions on Industrial Electronics.

[2]  F. Blaabjerg,et al.  A new method of on-line grid impedance estimation for PV inverter , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[3]  Poh Chiang Loh,et al.  Design, analysis, and real-time testing of a controller for multibus microgrid system , 2004, IEEE Transactions on Power Electronics.

[4]  F. Blaabjerg,et al.  Online grid impedance measurement suitable for multiple PV inverters running in parallel , 2006, Twenty-First Annual IEEE Applied Power Electronics Conference and Exposition, 2006. APEC '06..

[5]  Roberto Petrella,et al.  Advances on inter-harmonic variable-frequency injection-based grid-impedance estimation methods suitable for PV inverters , 2009, 2009 IEEE Energy Conversion Congress and Exposition.

[6]  W. Bower,et al.  Evaluation of Islanding Detection Methods for Utility-Interactive Inverters in Photovoltaic Systems , 2002 .

[7]  Frede Blaabjerg,et al.  On-line grid impedance estimation based on harmonic injection for grid-connected PV inverter , 2007, 2007 IEEE International Symposium on Industrial Electronics.

[8]  P. Garcia,et al.  Dynamic Behavior of Current Controllers for Selective Harmonic Compensation in Three-Phase Active Power Filters , 2013, IEEE Transactions on Industry Applications.

[9]  M. Sumner,et al.  A High Performance Harmonic Current Control for Shunt Active Filters Based on Resonant Compensators , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[10]  Paolo Mattavelli,et al.  Repetitive-based control for selective harmonic compensation in active power filters , 2004, IEEE Transactions on Industrial Electronics.

[11]  M. Liserre,et al.  Overview of Anti-Islanding Algorithms for PV Systems. Part I: Passive Methods , 2006, 2006 12th International Power Electronics and Motion Control Conference.

[13]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[14]  F. Blaabjerg,et al.  A digital controlled PV-inverter with grid impedance estimation for ENS detection , 2005, IEEE Transactions on Power Electronics.

[15]  M.R. Iravani,et al.  Power Management Strategies for a Microgrid With Multiple Distributed Generation Units , 2006, IEEE Transactions on Power Systems.

[16]  Alexandre Oudalov,et al.  Islanding detection in smart grids , 2010, 2010 IEEE Energy Conversion Congress and Exposition.