Closed-face filter cassette (CFC) sampling-guidance on procedures for inclusion of material adhering to internal sampler surfaces.

The sampling and analytical methods published in the NIOSH Manual of Analytical Methods (NMAM)(1) represent state-of-the-art methods for assessing worker exposures to toxic chemicals. Aerosol sampling methods generally specify the collection of workplace air samples using samplers containing filters such as 37-mm closed-face cassettes (CFCs). NIOSH considers that all particles entering CFCs, as well as some other samplers, such as the Institute of Occupational Medicine (IOM) sampler, should be included as part of the sample whether they deposit on the filter or on the inside surfaces of the sampler. This matter has been discussed in detail in the section on “Sampler Wall Losses” of NMAM Chapter O(2) and has also been specifically addressed in a gravimetric method promulgated by the Occupational Safety and Health Administration (OSHA).(3) The most accurate measure of occupational exposures therefore includes all aerosol particles entering workplace air samplers, both for gravimetric analysis and for analytes such as metals and metalloids. Hence, following sampling, i.e., during sample preparation and analysis, procedures should be used to account for material adhering to the internal surfaces of air sampling cassettes.

[1]  Martin Harper,et al.  Size Distributions of 0.5 to 20 μm Aerodynamic Diameter Lead-Containing Particles from Aerosol Sampler Walls and Filters , 2009 .

[2]  Richard Wrobel,et al.  Field comparison of 37-mm closed-face cassettes and IOM samplers. , 2002, Applied occupational and environmental hygiene.

[3]  Dean Lillquist,et al.  On Wiping the Interior Walls of 37-mm Closed-Face Cassettes: An OSHA Perspective , 2009, Journal of occupational and environmental hygiene.

[4]  Martin Harper,et al.  Comparison of Filter and Wall Deposits From Samplers Used to Collect Airborne Lead-Containing Dusts at Field Sites , 2012 .

[5]  M A Puskar,et al.  Internal wall losses of pharmaceutical dusts during closed-face, 37-mm polystyrene cassette sampling. , 1991, American Industrial Hygiene Association journal.

[6]  Martin Harper,et al.  Concerning sampler wall deposits in the chemical analysis of airborne metals. , 2007, Journal of occupational and environmental hygiene.

[7]  Kevin Ashley,et al.  Ultra-trace determination of beryllium in occupational hygiene samples by ammonium bifluoride extraction and fluorescence detection using hydroxybenzoquinoline sulfonate. , 2007, Analytica chimica acta.

[8]  Martin Harper,et al.  A review of workplace aerosol sampling procedures and their relevance to the assessment of beryllium exposures. , 2006, Journal of environmental monitoring : JEM.

[9]  Roger Frost,et al.  International Organization for Standardization (ISO) , 2004 .

[10]  Kevin Ashley,et al.  Preliminary Studies on the Use of Acid-Soluble Cellulose Acetate Internal Capsules for Workplace Metals Sampling and Analysis , 2012, Journal of occupational and environmental hygiene.

[11]  Kevin Ashley,et al.  Evaluation of sequential extraction procedures for soluble and insoluble hexavalent chromium compounds in workplace air samples. , 2009, Journal of environmental monitoring : JEM.

[12]  Robin Gill,et al.  Inductively coupled plasma-atomic emission spectrometry (ICP-AES) , 2014 .

[13]  Martin Harper,et al.  Workplace Aerosol Measurement , 2011 .

[14]  M. Demange,et al.  AEROSOL EVALUATION DIFFICULTIES DUE TO PARTICLE DEPOSITION ON FILTER HOLDER INNER WALLS , 1990 .

[15]  Kevin Ashley,et al.  Ultrasonic extraction as a sample preparation technique for elemental analysis by atomic spectrometry , 2001 .

[16]  LR Dobson,et al.  Evaluation of Quartz Residue on Cassette Interiors of AIHA Proficiency Samples , 2005 .

[17]  Melecita M. Archuleta,et al.  The Real Issue with Wall Deposits in Closed Filter Cassettes—What's the Sample? , 2009, Journal of occupational and environmental hygiene.