Closed-face filter cassette (CFC) sampling-guidance on procedures for inclusion of material adhering to internal sampler surfaces.
暂无分享,去创建一个
[1] Martin Harper,et al. Size Distributions of 0.5 to 20 μm Aerodynamic Diameter Lead-Containing Particles from Aerosol Sampler Walls and Filters , 2009 .
[2] Richard Wrobel,et al. Field comparison of 37-mm closed-face cassettes and IOM samplers. , 2002, Applied occupational and environmental hygiene.
[3] Dean Lillquist,et al. On Wiping the Interior Walls of 37-mm Closed-Face Cassettes: An OSHA Perspective , 2009, Journal of occupational and environmental hygiene.
[4] Martin Harper,et al. Comparison of Filter and Wall Deposits From Samplers Used to Collect Airborne Lead-Containing Dusts at Field Sites , 2012 .
[5] M A Puskar,et al. Internal wall losses of pharmaceutical dusts during closed-face, 37-mm polystyrene cassette sampling. , 1991, American Industrial Hygiene Association journal.
[6] Martin Harper,et al. Concerning sampler wall deposits in the chemical analysis of airborne metals. , 2007, Journal of occupational and environmental hygiene.
[7] Kevin Ashley,et al. Ultra-trace determination of beryllium in occupational hygiene samples by ammonium bifluoride extraction and fluorescence detection using hydroxybenzoquinoline sulfonate. , 2007, Analytica chimica acta.
[8] Martin Harper,et al. A review of workplace aerosol sampling procedures and their relevance to the assessment of beryllium exposures. , 2006, Journal of environmental monitoring : JEM.
[9] Roger Frost,et al. International Organization for Standardization (ISO) , 2004 .
[10] Kevin Ashley,et al. Preliminary Studies on the Use of Acid-Soluble Cellulose Acetate Internal Capsules for Workplace Metals Sampling and Analysis , 2012, Journal of occupational and environmental hygiene.
[11] Kevin Ashley,et al. Evaluation of sequential extraction procedures for soluble and insoluble hexavalent chromium compounds in workplace air samples. , 2009, Journal of environmental monitoring : JEM.
[12] Robin Gill,et al. Inductively coupled plasma-atomic emission spectrometry (ICP-AES) , 2014 .
[13] Martin Harper,et al. Workplace Aerosol Measurement , 2011 .
[14] M. Demange,et al. AEROSOL EVALUATION DIFFICULTIES DUE TO PARTICLE DEPOSITION ON FILTER HOLDER INNER WALLS , 1990 .
[15] Kevin Ashley,et al. Ultrasonic extraction as a sample preparation technique for elemental analysis by atomic spectrometry , 2001 .
[16] LR Dobson,et al. Evaluation of Quartz Residue on Cassette Interiors of AIHA Proficiency Samples , 2005 .
[17] Melecita M. Archuleta,et al. The Real Issue with Wall Deposits in Closed Filter Cassettes—What's the Sample? , 2009, Journal of occupational and environmental hygiene.