Ultra wide band VHF/UHF radio interferometer system for detecting partial discharge source

The electromagnetic (E-M) waves emitted from partial discharge (PD) generated by material defects in high-voltage electric power apparatus and facilities are broadband signals including VHF/UHF components. In this paper, the author proposes an ultra wide band VHF/UHF radio interferometer system (UWB-VURIS) for detecting PD source, which has been originally designed, constructed and tested. The system is based on the idea extracting the phase differences at different frequencies between a pair of the received E-M signals by the fast Fourier transform (FFT) and computing the arrival angle of the E-M waves emitted from PD source. It can be small-sized, more suitable for compact and portable systems. It is able to reduce the operating time at the measurement site because it is not needed to arrange many antennas at the many points. The indoor test results indicate that the UWB-VURIS is able to estimate the arrival angle of the E-M waves emitted from PD source.

[1]  Kenji Matsuura,et al.  Time-Frequency Analysis of Partial Discharge Phenomena in SF6 gas using Wavelet Transform , 1997 .

[2]  Z. Kawasaki,et al.  Development of a New System for Detecting Microwave Associated with a Partial Discharge of the Stator Coil in Generator Using Spatial Phase Difference Method , 1997 .

[3]  Z. Kawasaki,et al.  Insulation diagnostic technique to assess the condition of generator winding by measuring microwave associated with dielectric breakdown , 2000 .

[5]  Z. Kawasaki UHF Radiation and Laser Triggered Lightning Experiment in the Field , 1999 .

[6]  Xuan-Min Shao,et al.  Broad band radio interferometry for lightning observations , 1996 .

[7]  Z. Kawasaki,et al.  Location of Multiple PD Sources on Distribution Lines by Measuring Emitted Pulse-Train Electromagnetic Waves (特集:電線・ケーブル分野の新技術) , 2000 .

[9]  Kenji Matsuura,et al.  Location of Partial Discharge by Superimposed Positioning Optimization on the Time Delay of Arrival , 1998 .

[10]  B. F. Hampton,et al.  The excitation of UHF signals by partial discharges in GIS , 1996 .

[11]  Masayuki Hikita Future Trend of Partial Discharge Measurement Technique for Diagnosis of Insulation Performance of Electric Power Apparatus , 2001 .

[12]  Y. Takahashi,et al.  Very long baseline interferometer , 2002, IEEE Aerospace and Electronic Systems Magazine.

[13]  Kenji Matsuura,et al.  Insulation diagnosis method for generator winding by measuring microwaves associated with dielectric breakdown , 2000 .

[14]  Isao Masuda,et al.  A current sensor using the Faraday effect in optical fiber manufactured from flint glass , 1997 .

[15]  Kenji Matsuura,et al.  On-line partial discharge detection of turbine generator using gigahertz-band spatial phase difference method , 2000 .

[16]  Ampol Tungkanawanich,et al.  Detection of wide-band E-M signals emitted from partial discharge occurring in GIS using wavelet transform , 2000 .

[17]  Hitoshi Okubo Recent Research Activity and Future Trend of Electrical Insulation Diagnostic Technique for Electric Power Apparatus , 1999 .

[18]  Kenji Matsuura,et al.  Non-Contact Detection of Electromagnetic Noise Occurrence due to Partial Discharges by Spatial Phase Difference Method , 1995 .