Contralateral pneumothorax and pneumopericardium after dual-chamber pacemaker implantation: Mechanism, diagnosis, and treatment

[1]  Jagmeet P. Singh,et al.  Increased Perforation Risk with an MRI‐Conditional Pacing Lead: A Single‐Center Study , 2015, Pacing and clinical electrophysiology : PACE.

[2]  D. Sánchez-Quintana,et al.  Right atrial appendage and vestibule: further anatomical insights with implications for invasive electrophysiology. , 2013, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[3]  D. Hayes,et al.  Implant-Related Complications: Relevant Anatomy and an Approach for Prevention , 2012 .

[4]  Martin J Schalij,et al.  Implantation-related complications of implantable cardioverter-defibrillators and cardiac resynchronization therapy devices: a systematic review of randomized clinical trials. , 2011, Journal of the American College of Cardiology.

[5]  A. Adabağ,et al.  Long‐Term Mortality and Pacing Outcomes of Patients with Permanent Pacemaker Implantation after Cardiac Surgery , 2011, Pacing and clinical electrophysiology : PACE.

[6]  Daniel R. Frisch,et al.  Implantation Trends and Patient Profiles for Pacemakers and Implantable Cardioverter Defibrillators in the United States: 1993–2006 , 2010, Pacing and clinical electrophysiology : PACE.

[7]  V. Jain,et al.  Prevalence and Characterization of Asymptomatic Pacemaker and ICD Lead Perforation on CT , 2007, Pacing and clinical electrophysiology : PACE.

[8]  D. Yuh,et al.  Computed Tomography to Assess Possible Cardiac Lead Perforation , 2006, Pacing and clinical electrophysiology : PACE.

[9]  David L Hayes,et al.  Incidence and predictors of cardiac perforation after permanent pacemaker placement. , 2005, Heart rhythm.

[10]  Wen‐Chih Wu,et al.  Pneumopericardium and Pneumothorax After Permanent Pacemaker Implantation , 2005, Pacing and clinical electrophysiology : PACE.

[11]  C. Appleton,et al.  Pneumopericardium and pneumothorax contralateral to venous access site after permanent pacemaker implantation. , 2003, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[12]  M. Eldar,et al.  Randomized comparison of J-shaped and straight atrial screw-in pacing leads. , 2000, Mayo Clinic proceedings.

[13]  S. Huang,et al.  Acute Pericarditis Resulting From an Endocardial Active Fixation Screw‐In Atrial Lead , 1994, Pacing and clinical electrophysiology : PACE.

[14]  PhilipE. Hill Complications of Permanent Transvenous Cardiac Pacing: A 14‐Year Review of all Transvenous Pacemakers Inserted at One Community Hospital , 1987, Pacing and clinical electrophysiology : PACE.

[15]  M. Yousefifard,et al.  Diagnostic Accuracy of Chest Ultrasonography versus Chest Radiography for Identification of Pneumothorax: A Systematic Review and Meta-Analysis , 2014, Tanaffos.