Direct Estimation of Voxel-Wise Neurotransmitter Response Maps From Dynamic PET Data

Computational methods, such as the linear parametric neurotransmitter PET (lp-ntPET) method, have been developed to characterize the transient changes in radiotracer kinetics in the target tissue during endogenous neurotransmitter release. In this paper, we describe and evaluate a parametric reconstruction algorithm that uses an expectation maximization framework, along with the lp-ntPET model, to estimate the endogenous neurotransmitter response to stimuli directly from the measured PET data. Computer simulations showed that the proposed direct reconstruction method offers improved accuracy and precision for the estimated timing parameters of the neurotransmitter response at the voxel level ( ${t}_{d}=1\pm 2 $ min, for activation onset bias and standard deviation) compared with conventional post reconstruction modeling ( ${t}_{d}=4\pm 7 $ min). In addition, we applied the proposed direct parameter estimation methodology to a [11C]raclopride displacement study of an awake rat and generated parametric maps illustrating the magnitude of ligand displacement from striatum. Although the estimated parametric maps of activation magnitude obtained from both direct and post reconstruction methodologies suffered from false positive activations, the proposed direct reconstruction framework offered more reliable parametric maps when the activation onset parameter was constrained.

[1]  M T Madsen,et al.  A simplified formulation of the gamma variate function , 1992 .

[2]  Georgios I. Angelis,et al.  Evaluation of a direct 4D reconstruction method using generalised linear least squares for estimating nonlinear micro-parametric maps , 2014, Annals of Nuclear Medicine.

[3]  A. Reader,et al.  4D image reconstruction for emission tomography , 2014, Physics in medicine and biology.

[4]  Jenna M. Sullivan,et al.  Sex Differences in the Brain's Dopamine Signature of Cigarette Smoking , 2014, The Journal of Neuroscience.

[5]  Georgios I. Angelis,et al.  Direct reconstruction of parametric images using any spatiotemporal 4D image based model and maximum likelihood expectation maximisation , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[6]  Evan D. Morris,et al.  Estimating neurotransmitter kinetics with ntPET: A simulation study of temporal precision and effects of biased data , 2008, NeuroImage.

[7]  R. Leahy,et al.  Digimouse: a 3D whole body mouse atlas from CT and cryosection data , 2007, Physics in medicine and biology.

[8]  Guobao Wang,et al.  Generalized Algorithms for Direct Reconstruction of Parametric Images From Dynamic PET Data , 2009, IEEE Transactions on Medical Imaging.

[9]  A. Syrota,et al.  In Vivo Detection of Striatal Dopamine Release during Reward: A PET Study with [11C]Raclopride and a Single Dynamic Scan Approach , 2002, NeuroImage.

[10]  Roger N Gunn,et al.  Positron Emission Tomography Compartmental Models: A Basis Pursuit Strategy for Kinetic Modeling , 2002, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[11]  Andre Kyme,et al.  Calculated attenuation correction for awake small animal brain PET studies , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[12]  Georgios I. Angelis,et al.  Impact of erroneous kinetic model formulation in Direct 4D image reconstruction , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[13]  Jeih-San Liow,et al.  Linearized Reference Tissue Parametric Imaging Methods: Application to [11C]DASB Positron Emission Tomography Studies of the Serotonin Transporter in Human Brain , 2003, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[14]  Charles A Mistretta,et al.  Dynamic PET Denoising with HYPR Processing , 2010, Journal of Nuclear Medicine.

[15]  A. Lammertsma,et al.  Simplified Reference Tissue Model for PET Receptor Studies , 1996, NeuroImage.

[16]  Guobao Wang,et al.  An Optimization Transfer Algorithm for Nonlinear Parametric Image Reconstruction From Dynamic PET Data , 2012, IEEE Transactions on Medical Imaging.

[17]  Guobao Wang,et al.  Acceleration of the direct reconstruction of linear parametric images using nested algorithms , 2010, Physics in medicine and biology.

[18]  Clive Baldock,et al.  Optimised Motion Tracking for Positron Emission Tomography Studies of Brain Function in Awake Rats , 2011, PloS one.

[19]  Evan D. Morris,et al.  A linear model for estimation of neurotransmitter response profiles from dynamic PET data , 2012, NeuroImage.

[20]  C Lartizien,et al.  GATE: a simulation toolkit for PET and SPECT. , 2004, Physics in medicine and biology.

[21]  Andrew J. Reader,et al.  Direct 4D PET MLEM reconstruction of parametric images using the simplified reference tissue model with the basis function method , 2013 .

[22]  Wan-Chi Siu,et al.  A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: theory and simulation study , 1997, IEEE Transactions on Information Technology in Biomedicine.

[23]  Karmen K. Yoder,et al.  ntPET: A New Application of PET Imaging for Characterizing the Kinetics of Endogenous Neurotransmitter Release , 2005 .

[24]  Shuo Wang,et al.  A framework for designing dynamic lp-ntPET studies to maximize the sensitivity to transient neurotransmitter responses to drugs: Application to dopamine and smoking , 2017, NeuroImage.

[25]  Kris Thielemans,et al.  Convergence optimization of parametric MLEM reconstruction for estimation of Patlak plot parameters , 2011, Comput. Medical Imaging Graph..

[26]  Georgios I. Angelis,et al.  Direct estimation of neurotransmitter response in awake and freely moving animals , 2015, 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).

[27]  David J. Schlyer,et al.  Graphical Analysis of Reversible Radioligand Binding from Time—Activity Measurements Applied to [N-11C-Methyl]-(−)-Cocaine PET Studies in Human Subjects , 1990, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[28]  Rajendra D. Badgaiyan,et al.  A novel method for noninvasive detection of neuromodulatory changes in specific neurotransmitter systems , 2003, NeuroImage.

[29]  Vincent J. Cunningham,et al.  Parametric Imaging of Ligand-Receptor Binding in PET Using a Simplified Reference Region Model , 1997, NeuroImage.

[30]  Ronald Boellaard,et al.  Optimization algorithms and weighting factors for analysis of dynamic PET studies , 2006, Physics in medicine and biology.

[31]  Kris Thielemans,et al.  Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography. , 2008, Medical physics.

[32]  Evan D. Morris,et al.  Voxelwise lp‐ntPET for detecting localized, transient dopamine release of unknown timing: Sensitivity Analysis and Application to Cigarette Smoking in the PET Scanner , 2014, Human brain mapping.

[33]  Dean F. Wong,et al.  Accurate Event-Driven Motion Compensation in High-Resolution PET Incorporating Scattered and Random Events , 2008, IEEE Transactions on Medical Imaging.

[34]  Karmen K. Yoder,et al.  Assessing Dopaminergic Neurotransmission with PET: Basic Theory and Applications in Alcohol Research , 2011 .