Respiratory Frequency during Exercise: The Neglected Physiological Measure

The use of wearable sensor technology for athlete training monitoring is growing exponentially, but some important measures and related wearable devices have received little attention so far. Respiratory frequency (fR), for example, is emerging as a valuable measurement for training monitoring. Despite the availability of unobtrusive wearable devices measuring fR with relatively good accuracy, fR is not commonly monitored during training. Yet fR is currently measured as a vital sign by multiparameter wearable devices in the military field, clinical settings, and occupational activities. When these devices have been used during exercise, fR was used for limited applications like the estimation of the ventilatory threshold. However, more information can be gained from fR. Unlike heart rate, V˙O2, and blood lactate, fR is strongly associated with perceived exertion during a variety of exercise paradigms, and under several experimental interventions affecting performance like muscle fatigue, glycogen depletion, heat exposure and hypoxia. This suggests that fR is a strong marker of physical effort. Furthermore, unlike other physiological variables, fR responds rapidly to variations in workload during high-intensity interval training (HIIT), with potential important implications for many sporting activities. This Perspective article aims to (i) present scientific evidence supporting the relevance of fR for training monitoring; (ii) critically revise possible methodologies to measure fR and the accuracy of currently available respiratory wearables; (iii) provide preliminary indication on how to analyze fR data. This viewpoint is expected to advance the field of training monitoring and stimulate directions for future development of sports wearables.

[1]  Yan Liu,et al.  Validity and Reliability of Multiparameter Physiological Measurements Recorded by the Equivital Lifemonitor During Activities of Various Intensities , 2013, Journal of occupational and environmental hygiene.

[2]  Y. Honda,et al.  Relationship between ventilatory response and body temperature during prolonged submaximal exercise. , 2006, Journal of applied physiology.

[3]  C. Ugrinowitsch,et al.  Cardiopulmonary, blood metabolite and rating of perceived exertion responses to constant exercises performed at different intensities until exhaustion , 2011, British Journal of Sports Medicine.

[4]  K. Bär,et al.  Deriving respiration from high resolution 12-channel-ECG during cycling exercise , 2016 .

[5]  R. Eston,et al.  Effect of exercise-induced muscle damage on ventilatory and perceived exertion responses to moderate and severe intensity cycle exercise , 2009, European Journal of Applied Physiology.

[6]  K B Pandolf,et al.  Perceptual responses to exercise: a multiple regression study. , 1973, Medicine and science in sports.

[7]  C. Spengler,et al.  Breathing pattern and exercise endurance time after exhausting cycling or breathing , 2000, European Journal of Applied Physiology.

[8]  K. Nakajima,et al.  Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique. , 1996, Medical engineering & physics.

[9]  R. Merin Monitoring the heart , 1984 .

[10]  M. Busse,et al.  Relation between plasma K+ and ventilation during incremental exercise after glycogen depletion and repletion in man. , 1991, The Journal of physiology.

[11]  R. Parkes,et al.  Rate of respiration: the forgotten vital sign. , 2011, Emergency nurse : the journal of the RCN Accident and Emergency Nursing Association.

[12]  J. Nw,et al.  Determination of Anaerobic Threshold by Ventilatory Frequency* , 1989, International journal of sports medicine.

[13]  C. Foster,et al.  Acoustic analysis of breath sounds as a surrogate for gas exchange thresholds. , 2014, Journal of sports science & medicine.

[14]  Jamie Kift,et al.  The respiratory time and flow profile at volitional exercise termination , 2007, Journal of sports sciences.

[15]  F. Felici,et al.  Mechanical and electromyographic responses during the 3-min all-out test in competitive cyclists. , 2015, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[16]  Samuele M. Marcora,et al.  Respiratory frequency is strongly associated with perceived exertion during time trials of different duration , 2016, Journal of sports sciences.

[17]  N. James,et al.  Determination of anaerobic threshold by ventilatory frequency. , 1989, International journal of sports medicine.

[18]  Won-Ki Kim,et al.  Improvement of Dynamic Respiration Monitoring Through Sensor Fusion of Accelerometer and Gyro-sensor , 2014 .

[19]  L. Passfield,et al.  Investigating the effect of exercise duration on functional and biochemical perturbations in the human heart: total work or ‘isoeffort’ matching? , 2016, The Journal of physiology.

[20]  A. Elliott,et al.  An examination of exercise mode on ventilatory patterns during incremental exercise , 2010, European Journal of Applied Physiology.

[21]  R. Eston,et al.  Eccentric exercise-induced muscle damage dissociates the lactate and gas exchange thresholds , 2011, Journal of sports sciences.

[22]  N. Secher,et al.  COUNTERPOINT: AFFERENT FEEDBACK FROM FATIGUED LOCOMOTOR MUSCLES IS NOT AN IMPORTANT DETERMINANT OF ENDURANCE EXERCISE PERFORMANCE , 2010 .

[23]  T. Cross,et al.  Evidence of break-points in breathing pattern at the gas-exchange thresholds during incremental cycling in young, healthy subjects , 2012, European Journal of Applied Physiology.

[24]  Samuele M. Marcora,et al.  Differential control of respiratory frequency and tidal volume during high‐intensity interval training , 2017, Experimental physiology.

[25]  U. Koehler,et al.  [Respiratory Rate - a Neglected Vital Sign]. , 2017, Deutsche medizinische Wochenschrift.

[26]  Eric T. Carlson,et al.  Development of three methods for extracting respiration from the surface ECG: a review. , 2014, Journal of electrocardiology.

[27]  I. Kosmidis,et al.  Linking the performance of endurance runners to training and physiological effects via multi-resolution elastic net , 2015, 1506.01388.

[28]  L. Tarassenko,et al.  Photoplethysmographic derivation of respiratory rate: a review of relevant physiology , 2012, Journal of medical engineering & technology.

[29]  Samuele M. Marcora Perception of effort during exercise is independent of afferent feedback from skeletal muscles, heart, and lungs. , 2009, Journal of applied physiology.

[30]  Rodrigo Villar,et al.  Validation of the Hexoskin wearable vest during lying, sitting, standing, and walking activities. , 2015, Applied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme.

[31]  L. Romer,et al.  Effect of expiratory muscle fatigue on exercise tolerance and locomotor muscle fatigue in healthy humans. , 2008, Journal of applied physiology.

[32]  Massimo Sacchetti,et al.  Control of the depth and rate of breathing: metabolic vs. non‐metabolic inputs , 2017, The Journal of physiology.

[33]  Takayoshi Yoshida,et al.  [Control of breathing during exercise]. , 1992, The Annals of physiological anthropology = Seiri Jinruigaku Kenkyukai kaishi.

[34]  D J Sanderson,et al.  Ventilation and locomotion coupling in varsity male rowers. , 1999, Journal of applied physiology.

[35]  S. Suzuki,et al.  Expiratory muscle training and sensation of respiratory effort during exercise in normal subjects. , 1995, Thorax.

[36]  K. Chon,et al.  Respiratory rate extraction from pulse oximeter and electrocardiographic recordings. , 2011, Physiological measurement.

[37]  J. Karvonen,et al.  Heart Rate and Exercise Intensity During Sports Activities , 1988, Sports medicine.

[38]  T. Noakes,et al.  The influence of peripheral afferent signals on the rating of perceived exertion and time to exhaustion during exercise at different intensities. , 2011, Psychophysiology.

[39]  F. Portaels,et al.  Management of Mycobacterium ulcerans infection in a pregnant woman in Benin using rifampicin and clarithromycin , 2008, The Medical journal of Australia.

[40]  Jeffrey B. Powell,et al.  Measurement Accuracy of Heart Rate and Respiratory Rate during Graded Exercise and Sustained Exercise in the Heat Using the Zephyr BioHarnessTM , 2012, International Journal of Sports Medicine.

[41]  D. O’Donnell,et al.  McArdle's disease presenting as unexplained dyspnea in a young woman. , 2004, Canadian respiratory journal.

[42]  A. Nicolò,et al.  Neuromuscular and metabolic responses to high-intensity intermittent cycling protocols with different work-to-rest ratios. , 2014, International journal of sports physiology and performance.

[43]  F. Felici,et al.  Comparing Continuous and Intermittent Exercise: An “Isoeffort” and “Isotime” Approach , 2014, PloS one.

[44]  Yan-Wei Guo,et al.  Estimation of respiration rate from three-dimensional acceleration data based on body sensor network. , 2011, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[45]  Andrew E. Kilding,et al.  Reliability and Validity of the Zephyr™ BioHarness™ to Measure Respiratory Responses to Exercise , 2011 .

[46]  S. Ward,et al.  Effect of interbreath fluctuations on characterizing exercise gas exchange kinetics. , 1987, Journal of applied physiology.

[47]  O. Faude,et al.  Reliability of time-to-exhaustion and selected psycho-physiological variables during constant-load cycling at the maximal lactate steady-state. , 2017, Applied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme.

[48]  K. Ebi,et al.  Tidal volume and respiratory timing derived from a portable ventilation monitor. , 2002, Chest.

[49]  R J Robertson,et al.  Effect of blood pH on peripheral and central signals of perceived exertion. , 1986, Medicine and science in sports and exercise.

[50]  Pablo Laguna,et al.  A robust method for ECG-based estimation of the respiratory frequency during stress testing , 2006, IEEE Transactions on Biomedical Engineering.

[51]  B. Kayser,et al.  Control and sensation of breathing during cycling exercise in hypoxia under naloxone: a randomised controlled crossover trial , 2013, Extreme Physiology & Medicine.

[52]  Franz Konstantin Fuss,et al.  Comparison of Non-Invasive Individual Monitoring of the Training and Health of Athletes with Commercially Available Wearable Technologies , 2016, Front. Physiol..

[53]  M. Mador,et al.  Effect of respiratory muscle fatigue on subsequent exercise performance. , 1991, Journal of applied physiology.

[54]  L. Passfield,et al.  A Mine of Information: Can Sports Analytics Provide Wisdom From Your Data? , 2017, International journal of sports physiology and performance.

[55]  Helma M de Morree,et al.  Locomotor muscle fatigue increases cardiorespiratory responses and reduces performance during intense cycling exercise independently from metabolic stress. , 2008, American journal of physiology. Regulatory, integrative and comparative physiology.

[56]  L. Tarassenko,et al.  An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram , 2016, Physiological measurement.

[57]  Y. Bhambhani,et al.  Validity of breathing frequency to monitor exercise intensity in trained cyclists. , 1995, International journal of sports medicine.

[58]  Simon C Gandevia,et al.  Respiratory rate: the neglected vital sign , 2008, The Medical journal of Australia.

[59]  A. Sheel,et al.  Measurement of exercise ventilation by a portable respiratory inductive plethysmograph , 2006, Respiratory Physiology & Neurobiology.