Simple and sensitive detection of cyanide using pinhole shell‐isolated nanoparticle‐enhanced Raman spectroscopy

Cyanide is a great threat to public health, environmental safety and homeland security because of its extremely high toxicity and widespread usage in industry. Countering such a threat can be greatly aided by a rapid, sensitive, on-site detection method. Here, a pinhole shell-isolated nanoparticle-enhanced Raman spectroscopy (SHINERS) technique for cyanide sensing has been established, and a limit of detection lower to 1 µg l−1 level in water was achieved on a portable Raman spectrometer, owing to the magnificent local electromagnetic field enhancement generated by the interaction between cyanide anion and the uncovered Au surface inside the pinholes. Meanwhile, the silica shell outside the Au core could significantly improve the stability of the substrate by preventing the dissolution of Au in cyanide solution, thereby making this assay more feasible for practical use. The linear range was from 1 to 100 µg l−1 with excellent selectivity over thiocyanide and other common ions. For applications on complex matrices such as polluted water, beverages etc., a simple online hydrogen generator was designed and successfully coupled with pinhole SHINERS to achieve a good measurement of cyanide. This pinhole SHINERS-based method is rapid, simple, with good stability and feasibility for the in-field detection of cyanide, and we hope that it will further raise more opportunities for portable SERS applications. Copyright © 2014 John Wiley & Sons, Ltd.

[1]  G. Frens Controlled Nucleation for the Regulation of the Particle Size in Monodisperse Gold Suspensions , 1973 .

[2]  Richard H. Clarke,et al.  Determination of cyanide in waste water by low‐resolution surface enhanced Raman spectroscopy on sol‐gel substrates , 2001 .

[3]  W. Tseng,et al.  Fluorescence turn-on detection of iodide, iodate and total iodine using fluorescein-5-isothiocyanate-modified gold nanoparticles. , 2009, The Analyst.

[4]  Matthew Brenner,et al.  Rapid point of care analyzer for the measurement of cyanide in blood. , 2011, Analytical chemistry.

[5]  R. Coleman,et al.  The mechanism of the oxidative dissolution of colloidal gold in cyanide media , 1998 .

[6]  Eric C Le Ru,et al.  Single-molecule surface-enhanced Raman spectroscopy. , 2012, Annual review of physical chemistry.

[7]  B. Probst,et al.  A straightforward method for the colorimetric detection of endogenous biological cyanide. , 2009, Analytical chemistry.

[8]  Steven D. Christesen,et al.  On-Line Spectroscopic Characterization of Sodium Cyanide with Nanostructured Gold Surface-Enhanced Raman Spectroscopy Substrates , 2002 .

[9]  M. Koper,et al.  Cyanide adsorption on gold electrodes: a combined surface enhanced Raman spectroscopy and density functional theory study , 2004 .

[10]  M. Eberhart,et al.  A Surfaced-Enhanced Raman Spectroscopy and Density Functional Theory Study of [Au(CN)2]−/[Au(CN)4]− Adsorbed on Gold Nanoparticles , 2011 .

[11]  R. Woods,et al.  A SERS spectroelectrochemical investigation of the interaction of sulfide species with gold surfaces , 2008 .

[12]  Samuel S. R. Dasary,et al.  A label-free gold-nanoparticle-based SERS assay for direct cyanide detection at the parts-per-trillion level. , 2011, Chemistry.

[13]  Pablo G. Etchegoin,et al.  Surface Enhanced Raman Scattering Enhancement Factors: A Comprehensive Study , 2007 .

[14]  Juyoung Yoon,et al.  A near-infrared fluorescent sensor for detection of cyanide in aqueous solution and its application for bioimaging. , 2010, Chemical communications.

[15]  W. Tseng,et al.  Colorimetric assay for cyanide and cyanogenic glycoside using polysorbate 40-stabilized gold nanoparticles. , 2011, Chemical communications.

[16]  Juyoung Yoon,et al.  Sensors for the optical detection of cyanide ion. , 2010, Chemical Society reviews.

[17]  M. Moskovits Surface‐enhanced Raman spectroscopy: a brief retrospective , 2005 .

[18]  A. Greenbaum,et al.  Analytical techniques for cyanide in blood and published blood cyanide concentrations from healthy subjects and fire victims , 2004 .

[19]  Yong Ding,et al.  Surface analysis using shell-isolated nanoparticle-enhanced Raman spectroscopy , 2012, Nature Protocols.

[20]  Y. Ozaki,et al.  Highly sensitive and selective determination of iodide and thiocyanate concentrations using surface-enhanced Raman scattering of starch-reduced gold nanoparticles. , 2011, Analytical chemistry.

[21]  K. S. Shin,et al.  Cyanide SERS as a platform for detection of volatile organic compounds and hazardous transition metal ions. , 2013, The Analyst.

[22]  S. Engelsen,et al.  Raman Spectroscopic Analysis of Cyanogenic Glucosides in Plants: Development of a Flow Injection Surface-Enhanced Raman Scatter (FI-SERS) Method for Determination of Cyanide , 2004, Applied spectroscopy.

[23]  Martin Moskovits,et al.  Persistent misconceptions regarding SERS. , 2013, Physical chemistry chemical physics : PCCP.

[24]  Zhong Lin Wang,et al.  Shell-isolated nanoparticle-enhanced Raman spectroscopy , 2010, Nature.

[25]  J. Rohrer,et al.  Direct determination of free cyanide in drinking water by ion chromatography with pulsed amperometric detection. , 2007, Journal of chromatography. A.

[26]  L Szinicz,et al.  History of chemical and biological warfare agents. , 2005, Toxicology.

[27]  M. Fleischmann,et al.  Raman spectra of pyridine adsorbed at a silver electrode , 1974 .

[28]  Tuan Vo-Dinh,et al.  SERS chemical sensors and biosensors: new tools for environmental and biological analysis☆ , 1995 .

[29]  J. Hamel A review of acute cyanide poisoning with a treatment update. , 2011, Critical care nurse.