PET and MR Imaging: The Odd Couple or a Match Made in Heaven?

PET and MR imaging are modalities routinely used for clinical and research applications. Integrated scanners capable of acquiring PET and MR imaging data in the same session, sequentially or simultaneously, have recently become available for human use. In this article, we describe some of the technical advances that allowed the development of human PET/MR scanners; briefly discuss methodologic challenges and opportunities provided by this novel technology; and present potential oncologic, cardiac, and neuropsychiatric applications. These examples range from studies that might immediately benefit from PET/MR to more advanced applications on which future development might have an even broader impact.

[1]  W. Cullen,et al.  Research confuses me: what is the difference between case-control and cohort studies in quantitative research? , 2013, Irish medical journal.

[2]  Arno Villringer,et al.  Physical and organizational provision for installation, regulatory requirements and implementation of a simultaneous hybrid PET/MR-imaging system in an integrated research and clinical setting , 2013, Magnetic Resonance Materials in Physics, Biology and Medicine.

[3]  Eveliina Arponen,et al.  Improved detection of localized prostate cancer using co-registered MRI and 11C-acetate PET/CT. , 2012, European journal of radiology.

[4]  Markus Schwaiger,et al.  Workflow and Scan Protocol Considerations for Integrated Whole-Body PET/MRI in Oncology , 2012, The Journal of Nuclear Medicine.

[5]  Bruce R. Rosen,et al.  fMRI at 20: Has it changed the world? , 2012, NeuroImage.

[6]  Ciprian Catana,et al.  MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI , 2012, The Journal of Nuclear Medicine.

[7]  C. Arango,et al.  Autism Spectrum Disorder: Does Neuroimaging Support the DSM-5 Proposal for a Symptom Dyad? A Systematic Review of Functional Magnetic Resonance Imaging and Diffusion Tensor Imaging Studies , 2011, Journal of Autism and Developmental Disorders.

[8]  C. Kuhl,et al.  MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence , 2012, The Journal of Nuclear Medicine.

[9]  R. Shah,et al.  Introducing Parametric Fusion PET/MRI of Primary Prostate Cancer , 2012, The Journal of Nuclear Medicine.

[10]  E. Matsusue,et al.  Correlation of apparent diffusion coefficients measured by diffusion-weighted MR imaging and standardized uptake values from FDG PET/CT in metastatic neck lymph nodes of head and neck squamous cell carcinomas. , 2012, Clinical imaging.

[11]  Yan Yin,et al.  18F-FDG PET, combined FDG-PET/CT and MRI for evaluation of bone marrow infiltration in staging of lymphoma: a systematic review and meta-analysis. , 2012, European journal of radiology.

[12]  T Schaeffter,et al.  Thoracic respiratory motion estimation from MRI using a statistical model and a 2-D image navigator , 2012, Medical Image Anal..

[13]  G. Delso,et al.  Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner , 2011, The Journal of Nuclear Medicine.

[14]  T. Kwee,et al.  Is MRI less accurate than FDG-PET/CT in diagnosing bone marrow involvement in lymphoma? , 2011, European journal of radiology.

[15]  W. Nishio,et al.  N stage disease in patients with non-small cell lung cancer: efficacy of quantitative and qualitative assessment with STIR turbo spin-echo imaging, diffusion-weighted MR imaging, and fluorodeoxyglucose PET/CT. , 2011, Radiology.

[16]  M. Bandstra,et al.  Measurements of Fukushima fallout by the Berkeley Radiological Air and Water Monitoring project , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[17]  Z. Fayad,et al.  MRI-based motion correction of thoracic PET: initial comparison of acquisition protocols and correction strategies suitable for simultaneous PET/MRI systems , 2011, European Radiology.

[18]  Jason S. Lewis,et al.  The next generation of positron emission tomography radiopharmaceuticals in oncology. , 2011, Seminars in nuclear medicine.

[19]  H. Zaidi,et al.  Design and performance evaluation of a whole-body Ingenuity TF PET–MRI system , 2011, Physics in medicine and biology.

[20]  Wendy Y. Zhang,et al.  Imaging Cardiac Stem Cell Therapy: Translations to Human Clinical Studies , 2011, Journal of cardiovascular translational research.

[21]  S. Voss Pediatric oncology and the future of oncological imaging , 2011, Pediatric Radiology.

[22]  T. Leiner,et al.  Accuracy of Gadofosveset-enhanced MRI for Nodal Staging and Restaging in Rectal Cancer , 2011, Annals of surgery.

[23]  Ciprian Catana,et al.  Bimodal thrombus imaging: simultaneous PET/MR imaging with a fibrin-targeted dual PET/MR probe--feasibility study in rat model. , 2011, Radiology.

[24]  Michael Souvatzoglou,et al.  Radionuclide and hybrid imaging of recurrent prostate cancer. , 2011, The Lancet. Oncology.

[25]  Ciprian Catana,et al.  MRI-Assisted PET Motion Correction for Neurologic Studies in an Integrated MR-PET Scanner , 2011, The Journal of Nuclear Medicine.

[26]  K-J Langen,et al.  High resolution BrainPET combined with simultaneous MRI , 2011, Nuklearmedizin.

[27]  C. Czerny,et al.  Functional imaging in head and neck squamous cell carcinoma: correlation of PET/CT and diffusion-weighted imaging at 3 Tesla , 2011, European Journal of Nuclear Medicine and Molecular Imaging.

[28]  R. Weissleder,et al.  MRI with Magnetic Nanoparticles Monitors Downstream Anti-Angiogenic Effects of mTOR Inhibition , 2011, Molecular Imaging and Biology.

[29]  J. Stoker,et al.  Diagnostic imaging of colorectal liver metastases with CT, MR imaging, FDG PET, and/or FDG PET/CT: a meta-analysis of prospective studies including patients who have not previously undergone treatment. , 2010, Radiology.

[30]  Ciprian Catana,et al.  Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype , 2010, The Journal of Nuclear Medicine.

[31]  C. Franzius FDG-PET/CT in pediatric solid tumors. , 2010, The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of....

[32]  Dieter Renker,et al.  Evaluation of Geiger-mode APDs for PET block detector designs , 2010, Physics in medicine and biology.

[33]  A. Alavi,et al.  Non-FDG PET in the practice of oncology. , 2010, Indian journal of cancer.

[34]  Ciprian Catana,et al.  Bimodal MR-PET agent for quantitative pH imaging. , 2010, Angewandte Chemie.

[35]  V. Torri,et al.  Performance of imaging modalities in diagnosis of liver metastases from colorectal cancer: A systematic review and meta‐analysis , 2010, Journal of magnetic resonance imaging : JMRI.

[36]  R. Günther,et al.  Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[37]  Keith A. Johnson,et al.  Functional Alterations in Memory Networks in Early Alzheimer’s Disease , 2010, NeuroMolecular Medicine.

[38]  Paul Kinahan,et al.  Weight-Based, Low-Dose Pediatric Whole-Body PET/CT Protocols , 2009, Journal of Nuclear Medicine.

[39]  I. Steffen,et al.  Early and late therapy response assessment with [18F]fluorodeoxyglucose positron emission tomography in pediatric Hodgkin's lymphoma: analysis of a prospective multicenter trial. , 2009, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[40]  F. Fahey Dosimetry of Pediatric PET/CT* , 2009, Journal of Nuclear Medicine.

[41]  J. Eary,et al.  [F‐18]‐fluorodeoxy‐D‐glucose–positron emission tomography response is associated with outcome for extremity osteosarcoma in children and young adults , 2009, Cancer.

[42]  McCarville Mb PET-CT imaging in pediatric oncology. , 2009 .

[43]  M. B. McCarville,et al.  PET-CT imaging in pediatric oncology , 2009, Cancer imaging : the official publication of the International Cancer Imaging Society.

[44]  H. Mayberg Targeted electrode-based modulation of neural circuits for depression. , 2009, The Journal of clinical investigation.

[45]  Nassir Navab,et al.  Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data , 2009, Journal of Nuclear Medicine.

[46]  Jin Hwan Kim,et al.  CT, MR, US, 18F-FDG PET/CT, and their combined use for the assessment of cervical lymph node metastases in squamous cell carcinoma of the head and neck , 2009, European Radiology.

[47]  Stephan G. Nekolla,et al.  PET and MRI in cardiac imaging: from validation studies to integrated applications , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[48]  H. Amièva,et al.  Prodromal Alzheimer's disease: Successive emergence of the clinical symptoms , 2008, Annals of neurology.

[49]  Bernhard Schölkopf,et al.  MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration , 2008, Journal of Nuclear Medicine.

[50]  E. Robbins,et al.  Radiation risks from imaging studies in children with cancer , 2008, Pediatric blood & cancer.

[51]  Ignace Lemahieu,et al.  MR-based attenuation correction for PET using an Ultrashort Echo Time (UTE) sequence , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[52]  C. Claussen,et al.  Simultaneous Mr/pet Imaging of the Human Brain: Feasibility Study 1 , 2022 .

[53]  Chenjie Xu,et al.  PET/MRI Dual-Modality Tumor Imaging Using Arginine-Glycine-Aspartic (RGD)–Conjugated Radiolabeled Iron Oxide Nanoparticles , 2008, Journal of Nuclear Medicine.

[54]  Benjamin R. Jarrett,et al.  Synthesis of 64Cu-labeled magnetic nanoparticles for multimodal imaging. , 2008, Bioconjugate chemistry.

[55]  In Chan Song,et al.  An Investigation Into the Use of Geiger-Mode Solid-State Photomultipliers for Simultaneous PET and MRI Acquisition , 2008, IEEE Transactions on Nuclear Science.

[56]  J. Baron,et al.  Relationships between Hippocampal Atrophy, White Matter Disruption, and Gray Matter Hypometabolism in Alzheimer's Disease , 2008, The Journal of Neuroscience.

[57]  Hans Herzog,et al.  Template-based attenuation correction of PET in hybrid MR-PET scanners , 2008 .

[58]  C. Jack,et al.  11C PiB and structural MRI provide complementary information in imaging of Alzheimer's disease and amnestic mild cognitive impairment. , 2008, Brain : a journal of neurology.

[59]  徳原 孝哉 Evaluation of lymph node metastases in gastric cancer using magnetic resonance imaging with ultrasmall superparamagnetic iron oxide (USPIO) : diagnostic performance in post-contrast images using new diagnostic criteria , 2008 .

[60]  Y. Tsushima,et al.  Clinicopathological presentation of varying 18F-FDG uptake and expression of glucose transporter 1 and hexokinase II in cases of hepatocellular carcinoma and cholangiocellular carcinoma , 2008, Annals of nuclear medicine.

[61]  I. Narabayashi,et al.  Evaluation of lymph node metastases in gastric cancer using magnetic resonance imaging with ultrasmall superparamagnetic iron oxide (USPIO): diagnostic performance in post-contrast images using new diagnostic criteria , 2008, Gastric Cancer.

[62]  Rika Takikawa,et al.  [In-vivo visualization of gene expression using magnetic resonance imaging]. , 2007, Tanpakushitsu kakusan koso. Protein, nucleic acid, enzyme.

[63]  H. Jadvar,et al.  PET and PET/CT in pediatric oncology. , 2007, Seminars in nuclear medicine.

[64]  J. Drevs,et al.  Phase I clinical study of AZD2171, an oral vascular endothelial growth factor signaling inhibitor, in patients with advanced solid tumors. , 2007, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[65]  Gerald Q. Maguire,et al.  Improving Specificity of Breast MRI Using Prone PET and Fused MRI and PET 3D Volume Datasets , 2007, Journal of Nuclear Medicine.

[66]  Mitchell D Schnall,et al.  Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Assessing Tumor Vascularity and Vascular Effects of Targeted Therapies in Renal Cell Carcinoma , 2007, Clinical Cancer Research.

[67]  이재성,et al.  An investigation into the use of Geiger-mode solid-state photomultipliers for simultaneous PET and MRI acquisition , 2007 .

[68]  J. Fütterer,et al.  Use of ultrasmall superparamagnetic iron oxide in lymph node MR imaging in prostate cancer patients. , 2007, European journal of radiology.

[69]  Tracy T Batchelor,et al.  AZD2171, a pan-VEGF receptor tyrosine kinase inhibitor, normalizes tumor vasculature and alleviates edema in glioblastoma patients. , 2007, Cancer cell.

[70]  T. Helbich,et al.  Axillary lymph node metastases in patients with breast carcinomas: assessment with nonenhanced versus uspio-enhanced MR imaging. , 2006, Radiology.

[71]  M. Robson,et al.  Clinical ultrashort echo time imaging of bone and other connective tissues , 2006, NMR in biomedicine.

[72]  Alda Pinto,et al.  USPIO‐enhanced magnetic resonance imaging for nodal staging in patients with head and neck cancer , 2006, Journal of magnetic resonance imaging : JMRI.

[73]  Kevin Camphausen,et al.  Antiangiogenic and antitumor effects of bevacizumab in patients with inflammatory and locally advanced breast cancer. , 2006, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[74]  Jingxian Shen,et al.  Evaluation of lymph node metastases in gastric cancer with spiral computed tomography , 2006 .

[75]  Benjamin J. Shannon,et al.  Molecular, Structural, and Functional Characterization of Alzheimer's Disease: Evidence for a Relationship between Default Activity, Amyloid, and Memory , 2005, The Journal of Neuroscience.

[76]  Matthew D Robson,et al.  Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences. , 2005, Magnetic resonance imaging.

[77]  Habib Zaidi,et al.  Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging , 2005, NeuroImage.

[78]  David W Townsend,et al.  PET/CT today and tomorrow. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[79]  M. Schwaiger,et al.  Performance test of a LSO-APD PET module in a 9.4 Tesla magnet , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[80]  S. Cherry,et al.  Simultaneous PET and MR imaging , 1997, Physics in medicine and biology.

[81]  J. Barendregt,et al.  Global burden of disease , 1997, The Lancet.