Enhancement of photoacoustic image quality by sound speed correction: ex vivo evaluation.

Real-time photoacoustic (PA) imaging involves beamforming methods using an assumed fixed sound speed, typically 1540 m/s in soft tissue. This leads to degradation of PA image quality because the true sound speed changes as PA signal propagates through different types of soft tissues: the range from 1450 m/s to 1600 m/s. This paper proposes a new method for estimating an optimal sound speed to enhance the cross-sectional PA image quality. The optimal sound speed is determined when coherent factor with the sound speed is maximized. The proposed method was validated through simulation and ex vivo experiments with microcalcification-contained breast cancer specimen. The experimental results demonstrated that the best lateral resolution of PA images of microcalcifications can be achieved when the optimal sound speed is utilized.

[1]  Changhong Hu,et al.  Photoacoustic imaging with a commercial ultrasound system and a custom probe. , 2011, Ultrasound in medicine & biology.

[2]  Lihong V. Wang,et al.  Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging , 2006, Nature Biotechnology.

[3]  B T Cox,et al.  k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields. , 2010, Journal of biomedical optics.

[4]  Bradley E Treeby,et al.  Automatic sound speed selection in photoacoustic image reconstruction using an autofocus approach. , 2011, Journal of biomedical optics.

[5]  Ronald I. Siphanto,et al.  Serial noninvasive photoacoustic imaging of neovascularization in tumor angiogenesis. , 2005, Optics express.

[6]  T. Harrison,et al.  The applicability of ultrasound dynamic receive beamformers to photoacoustic imaging , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  Suhyun Park,et al.  Adaptive beamforming for photoacoustic imaging. , 2008, Optics letters.

[8]  M. L. Li,et al.  Optoacoustic imaging with synthetic aperture focusing and coherence weighting. , 2004, Optics letters.

[9]  Jin Ho Chang,et al.  In vitro estimation of mean sound speed based on minimum average phase variance in medical ultrasound imaging. , 2011, Ultrasonics.

[10]  K. P. Köstli,et al.  Two-dimensional photoacoustic imaging by use of Fourier-transform image reconstruction and a detector with an anisotropic response. , 2003, Applied optics.

[11]  Wiendelt Steenbergen,et al.  Reflection mode photoacoustic measurement of speed of sound. , 2007, Optics express.

[12]  Sverre Holm,et al.  Wiener beamforming and the coherence factor in ultrasound imaging , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  Jin Ho Chang,et al.  Optimal laser wavelength for photoacoustic imaging of breast microcalcifications , 2011 .

[14]  M. O’Donnell,et al.  Phase-aberration correction using signals from point reflectors and diffuse scatterers: basic principles , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  Manojit Pramanik,et al.  Sentinel lymph nodes in the rat: noninvasive photoacoustic and US imaging with a clinical US system. , 2010, Radiology.

[16]  Lihong V. Wang,et al.  Photoacoustic imaging in biomedicine , 2006 .