Power quality assessment using an adaptive neural network

The paper presents an adaptive neutral network approach for the estimation of harmonic components of a power system and its power quality. The neural estimator is based on the use of an adaptive perceptron consisting of a linear adaptive neuron called Adaline. The learning parameters in the proposed algorithm are adjusted to force the error between the actual and desired outputs to satisfy a stable difference error equation. The estimator tracks the Fourier coefficients of the signal data corrupted with noise and decaying DC components very accurately. Adaptive tracking of harmonic components of a power system can easily be performed using this algorithm. Several numerical tests have been conducted for the adaptive estimation of harmonic components, total harmonic distortion and power quality of power system signals mixed with noise and decaying DC components.

[1]  Stefen Hui,et al.  Application of feedforward neural networks to dynamical system identification and control , 1993, IEEE Trans. Control. Syst. Technol..

[2]  John A. Orr,et al.  A survey of harmonic voltages and currents at distribution substations , 1991 .

[3]  Bernard Widrow,et al.  30 years of adaptive neural networks: perceptron, Madaline, and backpropagation , 1990, Proc. IEEE.

[4]  Stefen Hui,et al.  Application of Feedforward Neural Networks to , 1993 .

[5]  Alessandro Ferrero,et al.  A method and related digital instrument for the measurement of the electric power quality , 1995 .

[6]  Ewald F. Fuchs,et al.  Influence of harmonics on power distribution system protection , 1988 .

[7]  Adly Girgis,et al.  A Quantitative Study of Pitfalls in the FFT , 1980, IEEE Transactions on Aerospace and Electronic Systems.

[8]  L. Cristaldi,et al.  A digital method for the identification of the source of distortion in electric power systems , 1993, 1993 IEEE Instrumentation and Measurement Technology Conference.

[9]  Adly A. Girgis,et al.  Measurement and characterization of harmonic and high frequency distortion for a large industrial load , 1990 .

[10]  A. Girgis,et al.  A digital recursive measurement scheme for online tracking of power system harmonics , 1991 .

[11]  C. S. Moo,et al.  A digital measurement scheme for time-varying transient harmonics , 1995 .

[12]  M. Villablanca,et al.  Harmonic Reduction In Group-Connected Generators-HVDC Convertor , 1992, ICHPS V International Conference on Harmonics in Power Systems..

[13]  F. Harris On the use of windows for harmonic analysis with the discrete Fourier transform , 1978, Proceedings of the IEEE.