Optimum b value for resolving crossing fibers: a study with standard clinical b value using 1.5-T MR

IntroductionWe sought to investigate the optimum b value for resolving crossing fiber using high-angular resolution diffusion imaging (HARDI)-based multi-tensor tractography. The study tested the standard b values that are commonly used in the routine clinical setting.MethodsTen normal volunteers (five men and five women) with a mean age of 26.3 years (range, 22–32 years) were scanned using a 1.5-T clinical magnetic resonance unit. Single-shot echo-planar imaging was used for diffusion-weighted imaging with a diffusion-sensitizing gradient in 32 orientations. The b values of 700, 1,400, 2,100, and 2,800 s/m2 were used. Data postprocessing was performed using multi-tensor methods. The depiction of the optic nerves, optic tracts, and decussation of superior cerebellar peduncles were assessed.ResultsThe depictions of the nerve fibers were independent of the b values tested.ConclusionThe depiction of crossing fibers by HARDI-based multi-tensor tractography is not substantially influenced by b values ranging from 700 to 2,800 s/m2. Thus, the optimum b value within this range may be the lowest one considering the higher signal to noise ratio.

[1]  D. Parker,et al.  Analysis of partial volume effects in diffusion‐tensor MRI , 2001, Magnetic resonance in medicine.

[2]  P. Hagmann,et al.  Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging , 2005, Magnetic resonance in medicine.

[3]  Thomas Netsch,et al.  Quantitative evaluation of image-based distortion correction in diffusion tensor imaging , 2004, IEEE Transactions on Medical Imaging.

[4]  T E Conturo,et al.  Diffusion MRI: Precision, accuracy and flow effects , 1995, NMR in biomedicine.

[5]  B W Kreher,et al.  Multitensor approach for analysis and tracking of complex fiber configurations , 2005, Magnetic resonance in medicine.

[6]  T D Cradduck,et al.  National electrical manufacturers association , 1983, Journal of the A.I.E.E..

[7]  L. Frank Characterization of anisotropy in high angular resolution diffusion‐weighted MRI , 2002, Magnetic resonance in medicine.

[8]  N. Makris,et al.  High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity , 2002, Magnetic resonance in medicine.

[9]  S. Arridge,et al.  Detection and modeling of non‐Gaussian apparent diffusion coefficient profiles in human brain data , 2002, Magnetic resonance in medicine.

[10]  Mark W. Woolrich,et al.  Probabilistic diffusion tractography with multiple fibre orientations: What can we gain? , 2007, NeuroImage.

[11]  R Mark Henkelman,et al.  Orientational diffusion reflects fiber structure within a voxel , 2002, Magnetic resonance in medicine.

[12]  A. Kalnin,et al.  Identification of the corticospinal tracts achieved using blood-oxygen-level-dependent and diffusion functional MR imaging in patients with brain tumors. , 2001, AJNR. American journal of neuroradiology.

[13]  P. V. van Zijl,et al.  Three‐dimensional tracking of axonal projections in the brain by magnetic resonance imaging , 1999, Annals of neurology.

[14]  Alan Connelly,et al.  Direct estimation of the fiber orientation density function from diffusion-weighted MRI data using spherical deconvolution , 2004, NeuroImage.

[15]  Peter Boesiger,et al.  Resolving fiber crossing using advanced fast marching tractography based on diffusion tensor imaging , 2006, NeuroImage.

[16]  J W Belliveau,et al.  Conductivity Mapping of Biological Tissue Using Diffusion MRI , 1999, Annals of the New York Academy of Sciences.

[17]  Jonathan H Burdette,et al.  Diffusion-Weighted Imaging of Cerebral Infarctions: Are Higher b Values Better? , 2002, Journal of computer assisted tomography.

[18]  D. Tuch Q‐ball imaging , 2004, Magnetic resonance in medicine.

[19]  Pratik Mukherjee,et al.  Diffusion tensor imaging and fiber tractography in acute stroke. , 2005, Neuroimaging clinics of North America.