Four-channel magnetic resonance imaging receiver using frequency domain multiplexing.

An alternative technique that uses frequency domain multiplexing to acquire phased array magnetic resonance images is discussed in detail. The proposed method has advantages over traditional independent receiver chains in that it utilizes an analog-to-digital converter and a single-chip multicarrier receiver with high performance to reduce the size and cost of the phased array receiver system. A practical four-channel digital receiver using frequency domain multiplexing was implemented and verified on a home-built 0.3 T magnetic resonance imaging system. The experimental results confirmed that the cross talk between each channel was below -60 dB, the phase fluctuations were about 1 degrees , and there was no obvious signal-to-noise ratio degradation. It is demonstrated that the frequency domain multiplexing is a valuable and economical technique, particularly for array coil systems where the multichannel receiver is indispensable and dynamic range is not a critical problem.

[1]  Jin Hyung Lee,et al.  Broadband multicoil imaging using multiple demodulation hardware: A feasibility study , 2005, Magnetic resonance in medicine.

[2]  Jiang Yu,et al.  A complete digital radio-frequency source for nuclear magnetic resonance spectroscopy , 2002 .

[3]  X. Qin,et al.  Compensation for unknown acquisition delay caused by digital receiver without external synchronization in NMR and MRI , 2005, Magnetic Resonance Materials in Physics, Biology and Medicine.

[4]  Lawrence E. Crooks,et al.  A floating-point digital receiver for MRI , 2002, IEEE Transactions on Biomedical Engineering.

[5]  J A Bankson,et al.  Multi-channel magnetic resonance spectroscopy through time domain multiplexing. , 2001, Magnetic resonance imaging.

[6]  L. Wald,et al.  Theory and application of array coils in MR spectroscopy , 1997, NMR in biomedicine.

[7]  S M Wright,et al.  A sixteen-channel multiplexing upgrade for single channel receivers. , 2001, Magnetic resonance imaging.

[8]  M. McDougall,et al.  64‐channel array coil for single echo acquisition magnetic resonance imaging , 2005, Magnetic resonance in medicine.

[9]  Carl A. Michal,et al.  A high performance digital receiver for home-built nuclear magnetic resonance spectrometers , 2002 .

[10]  Thoralf Niendorf,et al.  Highly parallel volumetric imaging with a 32‐element RF coil array , 2004, Magnetic resonance in medicine.

[11]  R L Greenman,et al.  Improved resolution and signal-to-noise ratio in MRI via enhanced signal digitization. , 1998, Journal of magnetic resonance.

[12]  Jay Porter,et al.  Parallel acquisition of MR images using time multiplexed coils , 1992 .

[13]  Marc-André Delsuc,et al.  Improvement of dynamic range in NMR by oversampling , 1986 .

[14]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[15]  S M Wright,et al.  A four‐channel time domain multiplexer: A cost‐effective alternative to multiple receivers , 1994, Magnetic resonance in medicine.

[16]  R. Mark Henkelman,et al.  Dynamic range requirements for MRI , 2005 .

[17]  Robert A. Beckman,et al.  Guidelines for the Use of Oversampling in Protein NMR , 1995 .

[18]  Gengying Li,et al.  Frequency domain multiplexing for parallel acquisition of MR images , 2006 .