Target motion measurement without implanted markers and its validation by comparison with manually obtained data.

For an effective radiotherapy the exact tumor location must be determined. The localization has to take into account patient's setup position as well as internal organ motion. Among the different localization methods, the use of a computer tomography (CT) scanner in the therapy room has been proposed recently. Achieving a CT with the patient on the therapy couch, a patient's treatment position is captured. We present a method to locate tumor considering internal organ motion and displacements due to respiration. We tested the method with prostate and lung patients. The method found the most probable tumor position as well as, for high-mobility tumors located in the lung, its trajectory during the respiratory cycle. The results of this novel method were validated by comparison with manually determined target position.

[1]  Michel Rouzaud,et al.  Dosimetric implications of changes in patient repositioning and organ motion in conformal radiotherapy for prostate cancer. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  J. Adler,et al.  Robotic Motion Compensation for Respiratory Movement during Radiosurgery , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[3]  Andrew G. Lee,et al.  Evaluation of an ultrasound-based prostate target localization technique with an in-room CT-on-rails , 2004 .

[4]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[5]  Lei Dong,et al.  Use of portal images and BAT ultrasonography to measure setup error and organ motion for prostate IMRT: implications for treatment margins. , 2003, International journal of radiation oncology, biology, physics.

[6]  John Wong,et al.  Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients. , 2004, International journal of radiation oncology, biology, physics.

[7]  Paul A. Viola,et al.  Alignment by Maximization of Mutual Information , 1997, International Journal of Computer Vision.

[8]  K. Brock,et al.  An analysis of inter-fraction prostate deformation relative to implanted fiducial markers using finite element modelling , 2004 .

[9]  L Wang,et al.  Daily target localization for prostate patients based on 3D image correlation. , 2004, Physics in medicine and biology.