A weighted least-squares method for PET

In this paper, the authors present a reconstruction algorithm for positron emission tomography that minimizes a weighted least-squares (WLS) objective function. The weights are based on the covariance matrix of the model error and depend on the unknown parameters. The algorithm guarantees nonnegative estimates, and in simulation studies it converged faster and had significantly better resolution and contrast than the ML-EM algorithm. Although simulations suggest that the proposed algorithm is globally convergent, a proof of convergence has not been found yet. Nevertheless, the authors are able to show that it produces estimates that decrease the objective function monotonically with increasing iterations.

[1]  E. Hoffman,et al.  Quantitation in Positron Emission Computed Tomography: 4. Effect of Accidental Coincidences , 1981, Journal of computer assisted tomography.

[2]  E. Hoffman,et al.  Quantitation in positron emission computed tomography: 2. Effects of inaccurate attenuation correction. , 1979, Journal of computer assisted tomography.

[3]  Neal H. Clinthorne Constrained least squares vs. maximum likelihood reconstructions for Poisson data , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[4]  Linda Kaufman,et al.  Implementing and Accelerating the EM Algorithm for Positron Emission Tomography , 1987, IEEE Transactions on Medical Imaging.

[5]  T. Pan,et al.  Numerical study of multigrid implementations of some iterative image reconstruction algorithms , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[6]  Jeffrey A. Fessler Penalized weighted least-squares image reconstruction for positron emission tomography , 1994, IEEE Trans. Medical Imaging.

[7]  Zang-Hee Cho,et al.  Parallelization of the EM algorithm for 3-D PET image reconstruction , 1991 .

[8]  Katta G. Murty,et al.  Linear complementarity, linear and nonlinear programming , 1988 .

[9]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[10]  K. Lange,et al.  EM reconstruction algorithms for emission and transmission tomography. , 1984, Journal of computer assisted tomography.

[11]  M. E. Daube-Witherspoon,et al.  An iterative image space reconstruction algorithm suitable for volume ECT.IEEE Trans. , 1986 .

[12]  L. Shepp,et al.  A Statistical Model for Positron Emission Tomography , 1985 .

[13]  Linda Kaufman,et al.  Maximum likelihood, least squares, and penalized least squares for PET , 1993, IEEE Trans. Medical Imaging.

[14]  D. Titterington On the Iterative Image Space Reconstruction Algorthm for ECT , 1987, IEEE Transactions on Medical Imaging.

[15]  Eric C. Frey,et al.  Comparison between ML-EM and WLS-CG algorithms for SPECT image reconstruction , 1991 .