Glucose content in human skin: relationship with blood glucose levels.

In order to ascertain the dynamic relationship between the extracellular glucose in upper skin layers and blood glucose, skin suction blisters were raised in six Type 1 diabetic patients during a three-step glucose clamp. Blister glucose closely paralleled venous glucose (mean of r = 0.998). However, in three patients blister glucose was constantly lower than plasma glucose and this appeared to be related to their slower formation of skin blisters. A substantial difference in skin blister suction time was noted among patients and it was found that suction time was linearly correlated to glycosylated haemoglobin (HbA1C) (n = 6, r = 0.865, p = 0.026). It is concluded that a non-invasive blood glucose monitoring system could be successfully based on measurement of alterations in skin glucose contents.

[1]  J. A. Johnson,et al.  The role of the skin in carbohydrate metabolism. , 1972, Advances in metabolic disorders.

[2]  T. Lyons,et al.  Decrease in skin collagen glycation with improved glycemic control in patients with insulin-dependent diabetes mellitus. , 1991, The Journal of clinical investigation.

[3]  J. Korf,et al.  Continuous monitoring of glucose with a transcutaneous microdialysis probe , 1992, The Lancet.

[4]  R. Andres,et al.  Manual feedback technique for the control of blood glucose concentration , 1966 .

[5]  Norman Fleischer,et al.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. The Diabetes Control and Complications Trial Research Group. , 1993 .

[6]  D. Ewing,et al.  Relationship of Skin Thickness to Duration of Diabetes, Glycemic Control, and Diabetic Complications in Male IDDM Patients , 1989, Diabetes Care.

[7]  A. Worm,et al.  Interstitial fluid: exchange of macromolecules between plasma and skin interstitium. , 1981, Clinical physiology.

[8]  B. Buckingham,et al.  Relationship between the content of lysyl oxidase-dependent cross-links in skin collagen, nonenzymatic glycosylation, and long-term complications in type I diabetes mellitus. , 1990, The Journal of clinical investigation.

[9]  E. V. Thomas,et al.  Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation. , 1992, Clinical chemistry.

[10]  Pfeiffer Ef The glucose sensor: the missing link in diabetes therapy. , 1990 .

[11]  M B Sulzberger,et al.  Studies on blisters produced by friction. II. The blister fluid. , 1968, The Journal of investigative dermatology.

[12]  B. Pagurek,et al.  The development of a glucose clamp. , 1975, Metabolism: clinical and experimental.

[13]  B H Ginsberg,et al.  An overview of minimally invasive technologies. , 1992, Clinical chemistry.

[14]  T. Chalmers,et al.  Meta-analysis of effects of intensive blood-glucose control on late complications of type I diabetes , 1993, The Lancet.

[15]  R. DeFronzo,et al.  Glucose clamp technique: a method for quantifying insulin secretion and resistance. , 1979, The American journal of physiology.

[16]  F. Reman,et al.  The determination of lipids and proteins in suction blister fluid. , 1979, The Journal of investigative dermatology.

[17]  R. Paisey,et al.  CORRELATION BETWEEN SKIN GLYCOSYLATION AND GLYCAEMIC CONTROL IN HUMAN DIABETES , 1984, Clinical endocrinology.

[18]  P. Reichard,et al.  The effect of long-term intensified insulin treatment on the development of microvascular complications of diabetes mellitus. , 1993, The New England journal of medicine.

[19]  U Kiistala,et al.  Suction blister device for separation of viable epidermis from dermis. , 1968, The Journal of investigative dermatology.

[20]  J. Bülow,et al.  Microdialysis of the interstitial water space in human skin in vivo: quantitative measurement of cutaneous glucose concentrations. , 1992, The Journal of investigative dermatology.