Practical Time-Resolved Fluorescence Spectroscopy: Avoiding Artifacts and Using Lifetime Standards

In this chapter we describe how artifacts can be avoided in the two most commonly used time-resolved fluorometries, namely the single-photon timing and the multifrequency phase-modulation techniques. The most frequently encountered artifacts (inner filter effect, autofluorescence, polarization effects, color effect, photobleaching, deoxygenation, pulse pile-up, and linearity of the time response in the time-to-amplitude converter) are described in detail and remedies are presented to avoid these pitfalls. An extensive list of fluorescence lifetime standards is presented, which allows the spectroscopist to calibrate and test time-resolved instruments for systematic errors.

[1]  E. Gratton,et al.  The Measurement and Analysis of Heterogeneous Emissions by Multifrequency Phase and Modulation Fluorometry , 1984 .

[2]  Frederick E. Petry,et al.  Principles and Applications , 1997 .

[3]  P. Wahl,et al.  The wavelength dependence of the response of a pulse fluorometer using the single photoelectron counting method , 1974 .

[4]  D. Bebelaar Time response of various types of photomultipliers and its wavelength dependence in time‐correlated single‐photon counting with an ultimate resolution of 47 ps FWHM , 1986 .

[5]  E Gratton,et al.  Multifrequency phase and modulation fluorometry. , 1984, Annual review of biophysics and bioengineering.

[6]  E Gratton,et al.  Phase fluorometric method for determination of standard lifetimes. , 1988, Analytical chemistry.

[7]  D. O'connor,et al.  Time-Correlated Single Photon Counting , 1984 .

[8]  James N. Demas,et al.  Excited State Lifetime Measurements , 1983 .

[9]  Michael Zuker,et al.  Delta function convolution method (DFCM) for fluorescence decay experiments , 1985 .

[10]  N. Ramanujam,et al.  Steady-state fluorescence imaging of neoplasia. , 2003, Methods in enzymology.

[11]  P. Wahl,et al.  Pulsefluorimetry of tyrosyl peptides. , 1978, Biophysical chemistry.

[12]  Matthew Lybanon,et al.  A better least‐squares method when both variables have uncertainties , 1984 .

[13]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[14]  S. Suzuki,et al.  Ultrafast microchannel plate photomultipliers. , 1988, Applied optics.

[15]  M. Barkley,et al.  Comparison of approaches to the instrumental response function in fluorescence decay measurements. , 1986, Analytical biochemistry.

[16]  P. D. Bell,et al.  Confocal and two-photon microscopy. , 2003, Methods in molecular medicine.

[17]  D. F. Eaton,et al.  International Union of Pure and Applied Chemistry Organic Chemistry Division Commission on Photochemistry. Reference materials for fluorescence measurement. , 1988, Journal of photochemistry and photobiology. B, Biology.

[18]  N. Tamai,et al.  Fluorescence lifetime standards for time and frequency domain fluorescence spectroscopy. , 2007, Analytical chemistry.

[19]  B. Valeur,et al.  Correction of systematic phase errors in frequency-domain fluorometry , 1989 .

[20]  S. Provencher,et al.  Double beam fluorescence lifetime spectrometer with subnanosecond resolution: Application to aqueous tryptophan , 1982 .

[21]  A. Diaspro Confocal and two-photon microscopy : foundations, applications, and advances , 2001 .

[22]  W. Baeyens,et al.  Luminescence Techniques in Chemical and Biochemical Analysis , 1990 .

[23]  A. Visser,et al.  Artefact and distortion sources in time correlated single photon counting , 1985 .

[24]  E W Small,et al.  F/F deconvolution of fluorescence decay data. , 1984, Analytical biochemistry.

[25]  D. Massart Chemometrics: A Textbook , 1988 .

[26]  I. Yamazaki,et al.  Picosecond single photon timing measurements with a proximity type microchannel plate photomultiplier and global analysis with reference convolution , 1990 .

[27]  M. Ameloot,et al.  On the use and the performance of the delta function convolution method for the estimation of fluorescence decay parameters , 1988 .

[28]  I. Yamazaki,et al.  Microchannel‐plate photomultiplier applicability to the time‐correlated photon‐counting method , 1985 .

[29]  R. E. Dale,et al.  Time-Resolved Fluorescence Spectroscopy in Biochemistry and Biology , 1983, NATO Advanced Science Institutes Series.

[30]  N. Boens,et al.  Possibilities and limitations of the time-correlated single photon counting technique: a comparative study of correction methods for the wavelength dependence of the instrument response function , 1986 .

[31]  S. Standard GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT , 2006 .

[32]  A. McKinnon,et al.  Confidence in fluorescence lifetime determinations: a ratio correction for the photomultiplier time response with wavelength , 1976 .

[33]  I. Yamazaki,et al.  Applicability of a microchannel plate photo-multiplier to the time-correlated photon counting technique. , 1982, Applied optics.

[34]  M. Ameloot,et al.  Pitfalls and Their Remedies in Time-Resolved Fluorescence Spectroscopy and Microscopy , 2005, Journal of Fluorescence.

[35]  B. Valeur,et al.  Molecular Fluorescence: Principles and Applications , 2001 .

[36]  D. F. Eaton Recommended methods for fluorescence decay analysis , 1990 .